Roberto Massari

Dr. Roberto Massari

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CTC. Trotta
C. Trotta
RMRoberto Massari
Roberto Massari
NPN. Palermo
N. Palermo
FSF. Scopinaro
F. Scopinaro
ASAlessandro Soluri
Alessandro Soluri

20 November 2008 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ABArmando Bartolazzi
Armando Bartolazzi
CDCalogero D'Alessandria
Calogero D'Alessandria
MPMaria Gemma Parisella
Maria Gemma Parisella
Alberto SignoreAlberto Signore
Alberto Signore
FPFabrizio Del Prete
Fabrizio Del Prete
FSFrancesco Scopinaro
Francesco Scopinaro
The prevalence of thyroid nodules increases with age, average 4–7% for the U.S.A. adult population, but it is much higher (19–67%) when sub-clinical nodules are considered. About 90% of these lesions are benign and a reliable approach to their preoperative characterization is necessary. Unfortunately conventional thyroid scintigraphy does not allow the distinction among benign and malignant thyroid proliferations but it provides only functional information (cold or hot nodules). The expression of the anti-apoptotic molecule galectin-3 is restricted to cancer cells and this feature has potential diagnostic and therapeutic implications. We show here the possibility to obtain thyroid cancer imaging in vivo by targeting galectin-3. The galectin-3 based thyroid immuno-scintigraphy uses as radiotracer a specific 99mTc-radiolabeled mAb. A position-sensitive high-resolution mini-gamma camera was used as imaging capture device. Human galectin-3 positive thyroid cancer xenografts (ARO) and galectin-3 knockout tumors were used as targets in different experiments in vivo. 38 mice with tumor mass of about 1 gm were injected in the tail vein with 100 µCi of 99mTc-labeled mAb to galectin-3 (30 µg protein/in 100 µl saline solution). Tumor images were acquired at 1 hr, 3 hrs, 6 hrs, 9 hrs and 24 hrs post injection by using the mini-gamma camera. Results from different consecutive experiments show an optimal visualization of thyroid cancer xenografts between 6 and 9 hours from injection of the radiotracer. Galectin-3 negative tumors were not detected at all. At 6 hrs post-injection galectin-3 expressing tumors were correctly visualized, while the whole-body activity had essentially cleared. These results demonstrate the possibility to distinguish preoperatively benign from malignant thyroid nodules by using a specific galectin-3 radio-immunotargeting. In vivo imaging of thyroid cancer may allow a better selection of patients referred to surgery. The possibility to apply this method for imaging and treatment of other galectin-3 expressing tumors is also discussed.

1 February 2008 in Cancer Biotherapy and Radiopharmaceuticals
Verified
Journal Article
Closed access
FSFrancesco Scopinaro
Francesco Scopinaro
ATAnna Tofani
Anna Tofani
GSGianpaolo di Santo
Gianpaolo di Santo
BPBarbara Di Pietro
Barbara Di Pietro
ALAugusto Lombardi
Augusto Lombardi
CAClaudio Amanti
Claudio Amanti
Background: The imaging probe (IP) is a high-resolution (HR), 1-in2 field-of-view hand-held gamma camera. We used it to detect breast cancer sentinel node (SN). Patients and Methods: We divided 120 T1 breast cancer patients, who underwent Anger camera lymphoscintigraphy (ACL), in two subgroups of 60 patients who were age, body mass index, and cancer size matched: subgroup A (SA) and B (SB). SN was detected with a common gamma probe (GP) in SA, with IP plus GP in SB. Results: Surgeons removed radioactive nodes without exceeding four nodes. Eighty-two (82) SNs were taken off in SA and 105 in SB (p < 0.01). Of SA, 22 of 60 patients and 36 of 60 patients of SB showed more than 1 node, and 3 of them showed 3 nodes and 1 showed 4 nodes. Thirteen (13) patients resulted N+ (21.6%) in SA. Ten (10) patients of SA showed an invasion on the hottest nodes and 3 on the second nodes. In the SB, 18 patients (25%) showed invasion. Sixteen (16) invasions were on hot, 4 on second, and 1 on the third node. Withdrawal time of SN was 11.25 ± 4.7 minutes for SA and 7.4 ± 2.8 minutes for SB (p < 0.025). Conclusions: SN biopsy with IP is fast and discovers more SNs and more invasions than ACL.

23 July 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
FMFlavia Mazzarda
Flavia Mazzarda
ADAnnunziata D'Elia
Annunziata D'Elia
RMRoberto Massari
Roberto Massari
ANAdele De Ninno
Adele De Ninno
FBFrancesca Romana Bertani
Francesca Romana Bertani
Fabio MammanoFabio Mammano
Fabio Mammano
Using microfluidics, ATP biosensors, multiphoton microscopy and genetically targeted mice, we show that ATP release through connexin hemichannels, and not pannexin 1 channels, underlies spontaneous Ca2+ wave propagation in the greater epithelial ridge of the developing cochlea.

16 September 2009 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
Gaurav MalviyaGaurav Malviya
Gaurav Malviya
CDCalogero D'ALessandria
Calogero D'ALessandria
Elena BonannoElena Bonanno
Elena Bonanno
VVVladimir Vexler
Vladimir Vexler
RMRoberto Massari
Roberto Massari
Alberto SignoreAlberto Signore
Alberto Signore
Visilizumab is an IgG2 humanized monoclonal antibody (mAb) characterized by non-FcγR binding and specific to the CD3 antigen, expressed on more than 95% of circulating resting T-lymphocytes and on activated T-lymphocytes homing in inflamed tissues. We hypothesized that the use of a radiolabeled anti-CD3 antibody might serve as a diagnostic tool for imaging T-cell traffic and lymphocytic infiltration of tissues and organs affected by autoimmune diseases. Here we describe the results of in vitro and animal experiments with 99mTc-succinimidyl-6-hydrazinonicotinate hydrochloride (SHNH)–visilizumab. Methods: For mAb labeling, we used a 2-step method with a heterobifunctional linker SHNH. Several titrations were performed to obtain the best labeling efficiency. In vitro quality controls included stability assay, cysteine challenge, sodium dodecyl sulfate polyacrylamide gel electrophoresis, binding assay, and immunoreactivity assay. In vivo studies by high-resolution images were performed at 6 and 24 h after the injection of 99mTc-SHNH–visilizumab. These included cell-targeting experiments in BALB/c mice xenografted subcutaneously with an increasing number of HuT78 cells in the leg and displaced with an excess of cold antibody. We also studied irradiated severe combined immunodeficient (SCID) mice reconstituted with human peripheral blood mononuclear cells (hPBMCs) and injected with 99mTc-labeled visilizumab or control mAb. After dynamic imaging for 3 h, major organs were removed, counted, and processed for immunohistologic examination. Results: Visilizumab was labeled with HYNIC with high labeling efficiency (>90%) and high specific activity (SA; 10,360–11,100 MBq/mg), with retained biochemical integrity and in vitro binding activity to CD3-positive cells. The in vivo targeting experiment showed a proportional increase of specific uptake with the number of injected cells, both at 6 and at 24 h, and the in vivo competition study demonstrated more than 60% decreased uptake after an excess of unlabeled antibody. In SCID mice, hPBMCs in different tissues were detected by 99mTc-labeled visilizumab and confirmed by histology. Conclusion: Visilizumab can be efficiently labeled with 99mTc with high efficiency and SA and could be a valuable tool for the study of human T-lymphocyte trafficking and lymphocytic infiltration of tissues and organs.

1 December 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ASAlessandro Soluri
Alessandro Soluri
RMRoberto Massari
Roberto Massari
CTC. Trotta
C. Trotta
LML. Montani
L. Montani
GIG. Iurlaro
G. Iurlaro
RSR. Scafè
R. Scafè