Few studies of long-term outcome of hypospadias treatment in terms of voiding, surgical complications, sexual functioning, intimate relationships and cosmetic results have been investigated and contrasting results have been obtained so far. The aim of our study is to investigate the long-term outcome of urinary and sexual function, cosmesis and the quality of intimate relationships in a series of hypospadias. In this study, 42 patients who underwent surgery for hypospadias were prospectively followed for 15 years. Medical records provided the hypospadias data, the number of reconstructive operations and the reconstruction technique that was used. Patients underwent physical examination, including penile length measurement and completed International Prostatic Symptoms Score (I-PSS), International Index Of Erectile Function (IIEF 15) and the Penile Perception Score questionnaire (PPPS). Twenty patients agreed to participate in the study. At the enrolment, the median value of HOSE was 13, as regards PPPS, 18/20 (90%) were satisfied, while in 1998 only 80% were satisfied. No significant statistical difference has been reported from the results obtained at enrolment and those obtained at follow-up, in terms of PPPS (P = 0.81), IPSS and IIEF-15. Penile length was 6.5 cm flaccid and 10.5 cm stretched. Our data show how cosmesis, function and psychosexual development for these patients are highly connected to surgical outcome, which is understood to be a decrease in penile size.
Background: This retrospective study reports on the early experience of a private surgical center with Motiva Ergonomix SilkSurface breast implants. Objectives: The aim of this study was to examine the incidence of complications and satisfaction levels in women who received primary and revision breast augmentation or augmentation-mastopexy with Ergonomix SilkSurface breast implants. Methods: A total of 356 consecutive patients received Ergonomix SilkSurface breast implants between April 2014 and October 2018 by 3 different surgeons and were followed-up for a minimum of 12 months. Complications were assessed by measuring the rate of rupture, capsular contracture, malposition, late seroma, double capsule, reoperation, symmastia, ptosis, extrusion, and infection. Satisfaction with aesthetic results was assessed on a Likert scale by both surgeon and patient. Results: Only 6 major complications were observed in these 356 patients (712 implants): 1 unilateral implant ptosis (“bottoming out”) at 12 months (0.14%) and 2 capsular contractures (0.28%), 1 at 14 months and 1 at 2 years. At all time points, 98% of the patients were “extremely satisfied or very satisfied” with the aesthetic results, and the surgeons categorized the outcomes as “very important or important improvement” in 96% of the cases. Conclusions: Motiva Ergonomix SilkSurface devices provided high patient satisfaction up to more than 5 years postoperatively with very few complications. These data are consistent with other reports in the literature. The observed favorable outcomes might be attributed, at least in part, to the bioengineered “cell-friendly” surface of these implants. Level of Evidence: 4: