Lara Milevoj Kopčinović

Dr. Lara Milevoj Kopčinović


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Biochemia Medica
Verified
Journal Article
Open access
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
JCJelena Culej
Jelena Culej
The pathological accumulation of serous fluids in the pleural, peritoneal and pericardial space occurs in a variety of conditions. Since patient management depends on right and timely diagnosis, biochemical analysis of extravascular body fluids is considered a valuable tool in the patient management process. The biochemical evaluation of serous fluids includes the determination of gross appearance, differentiation of transudative from exudative effusions and additional specific biochemical testing to assess the effusion etiology. This article summarized data from the most relevant literature concerning practice with special emphasis on usefulness of biochemical tests used for the investigation of pleural, peritoneal and pericardial effusions. Additionally, preanalytical issues concerning serous fluid analysis were addressed and recommendations concerning acceptable analytical practice in serous fluid analysis were presented.

1 January 2016 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
LDLora Dukić
Lora Dukić
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
ADAdrijana Dorotić
Adrijana Dorotić
IBIvana Baršić
Ivana Baršić
Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

1 January 2015 in Biochemia Medica
Verified
Journal Article
Open access
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
JTJasenka Trifunović
Jasenka Trifunović
TPTihana Pavosevic
Tihana Pavosevic
NGNora Nikolac Gabaj
Nora Nikolac Gabaj
Poor harmonization of critical results management is present in various laboratories and countries, including Croatia. We aimed to investigate procedures used in critical results reporting in Croatian medical biochemistry laboratories (MBLs). An anonymous questionnaire, consisting of 24 questions/statements, related to critical results reporting procedures, was send to managers of MBLs in Croatia. Participants were asked to declare the frequency of performing procedures and degree of agreement with statements about critical values reporting using a Likert scale. Total score and mean scores for corresponding separate statements divided according to health care setting were calculated and compared. Responses from 111 Croatian laboratories (48%) were analyzed. General practice laboratories (GPLs) more often re-analyzed the sample before reporting the critical result in comparison with the hospital laboratories (HLs) (score: 4.86 (4.75-4.96) vs. 4.49 (4.25-4.72); P=0.001) and more often reported the critical value exclusively to the responsible physician compared to HLs (4.46 (4.29-4.64) vs. 3.76 (3.48-4.03), P<0.001). High total score (4.69 (4.56-4.82)) was observed for selection of the critical results list issued by the Croatian Chamber of Medical Biochemistry (CCMB) indicating a high harmonization level for this aspect of critical result management. Low total scores were observed for the statements regarding data recording and documentation of critical result notification. Differences in practices about critical results reporting between HLs and GPLs were found. The homogeneity of least favorable responses detected for data recording and documentation of critical results notification reflects the lack of specific national recommendations.

14 June 2020 in Biochemia Medica
Verified
Journal Article
Open access
PDF file
NGNora Nikolac Gabaj
Nora Nikolac Gabaj
TPTomislav Pavicic
Tomislav Pavicic
AVAlen Vrtaric
Alen Vrtaric
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
DMDavorka Herman Mahecic
Davorka Herman Mahecic
AUAdriana Unic
Adriana Unic
Within the last several years, frequency of vitamin D testing has multiplied substantially all over the world, since it has been shown to have an important role in many diseases and conditions. Even though liquid chromatography - tandem mass spectrometry (LC-MS/MS) has been identified as “gold standard” method for vitamin D measurement, most laboratories still use immunochemistry methods. Besides analytical problems (hydrophobicity, low circulating concentrations, ability to bind to lipids, albumins and vitamin D binding protein, presence of multiple vitamin D metabolites and variable ratios of 25(OH)D2 and 25(OH)D3 in the blood), vitamin D shows great preanalytical variability, since its concentration is drastically influenced by seasonal changes, exposure to sun, type of clothes or sun block creams. Vitamin D is mostly measured in serum or plasma, but new studies are showing importance of measuring vitamin D in pleural effusions, breast milk, urine, synovial fluid and saliva. Besides the main role in calcium homeostasis and bone metabolism, many studies linked vitamin D deficiency with cancer, cardiovascular diseases, diabetes, fertility and many other conditions. However, even though initial observational studies indicated that supplementation with vitamin D might be beneficial in disease development and progression; first results of well-designed randomized controlled prospective studies did not find differences in frequency of cardiovascular events or invasive cancer between patients taking vitamin D supplementation compared to placebo. In the light of these recent findings, validity of excessive vitamin D testing remains an open question.

28 April 2016 in Biomarkers
Verified
Journal Article
Closed access
PDF file
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
ADAna-Marija Domijan
Ana-Marija Domijan
KPKsenija Posavac
Ksenija Posavac
IČIvana Čepelak
Ivana Čepelak
TGTihana Žanić Grubišić
Tihana Žanić Grubišić
LRLada Rumora
Lada Rumora
Context: Increased oxidative burden is found in chronic obstructive pulmonary disease (COPD). Objective: To assess the association of ceruloplasmin, albumin, bilirubin, transferrin, thiols and malondialdehyde (MDA) with stable COPD. Materials and methods: Oxidative stress markers measured in 106 COPD patients and 45 healthy subjects were evaluated. Results: Higher ceruloplasmin and MDA, and lower albumin, transferrin and thiols in COPD patients were found. Ceruloplasmin was the strongest single predictor of COPD. The model combining ceruloplasmin, albumin and thiols improved their individual diagnostic performances. Conclusions: Diagnostic characteristics of ceruloplasmin, albumin, transferrin, thiols and MDA suggest their potential value as additional tools in disease diagnosis.

1 January 2016 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
GJGordana Juričić
Gordana Juričić
ABAna Bakliza
Ana Bakliza
ASAndrea Saracevic
Andrea Saracevic
LKLara Milevoj Kopčinović
Lara Milevoj Kopčinović
SDSanja Dobrijevic
Sanja Dobrijevic
ASAna-Maria Simundic
Ana-Maria Simundic
Delayed sample processing can affect accurate glucose measurement. Our aim was to investigate the stability of glucose in samples collected in serum, sodium fluoride/potassium oxalate (NaF/KOx) and Glucomedics tubes processed according to different controlled pre-centrifugation delays (up to 180 min after venipuncture) in order to simulate prolonged sample transport between venipuncture and centrifugation. Samples were collected from healthy volunteers (n=80) into either serum or NaF/KOx and Glucomedics tubes. Glucose concentration was measured in samples centrifuged immediately after venipuncture and compared with tubes processed with a delay of 60, 120 and 180 min prior to centrifugation. Differences between baseline and respective delayed centrifugation glucose value for each tube type were tested using the paired t-test. Mean bias calculated for each tube type and delay protocol was compared to recommended quality specifications for glucose (2.2%). Glucose concentrations measured in all three delayed tube types were lower in comparison to respective baseline glucose concentrations measured in immediately processed tube (p<0.001). The highest decrease in glucose was observed in serum tubes in all specified time points (p<0.001), while glucose was most stable in Glucomedics tubes (p<0.001). The decrease in glucose observed for serum and NaF/KOx tubes was clinically significant at all specified time points while the bias for Glucomedics tubes did not exceed the criteria even with a centrifugation delay of 180 min. Glucose stability in un-centrifuged Glucomedics tubes is much superior to serum and NaF/KOx tubes. Glucomedics tubes can be left un-centrifuged for up to 3 h without affecting glucose concentration.