Jacob Gonzalez

Mr. Jacob Gonzalez

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JGJose Gisbert-Orozco
Jose Gisbert-Orozco
Bruno Fernández-ValdésBruno Fernández-Valdés
Bruno Fernández-Valdés
Robert ArcosRobert Arcos
Robert Arcos
JGJacob Gonzalez
Jacob Gonzalez
CRCarlos Ramirez-Lopez
Carlos Ramirez-Lopez
GFGerard Moras Feliu
Gerard Moras Feliu
The positive effects of whole-body vibration exercise in rehabilitation, sport, fitness and preventive medicine have led to a proliferation of vibrating platforms. However, discrepancies have been claimed between the manufacturers’ vibration parameters and the vibration applied by the platforms. In addition, the dimensions, materials and motors used in their manufacture mean that each platform behaves differently. These factors can influence their transmission to the human body and, consequently, their effects. Thus, measured vibration parameters were recommended to report the vibration parameters as accurately as possible. Therefore, the present study aimed to determine the feasibility of a large vibration platform. Measurements of vibration parameters and their transmission were added. These parameters were measured using six accelerometers (platform, ankle, knee, hip, third lumbar vertebra, and head) throughout five postures (toe-standing, erect, high squat, deep squat, and lunge) and three vibration frequencies (20 Hz, 25 Hz, and 30 Hz). On the platform, peak accelerations of 1 ± 0.2 g, displacements of 1 ± 0.1 mm at 20 Hz and 25 Hz and 0.6 mm at 30 Hz, and a frequency from the setting of +0.5 Hz were obtained. In the human body, peak accelerations can exceed 2 g, and these transmissibility amplifications were found at the ankles and knees. However, at the hip, accelerations plummet and transmissibility attenuation occurs all the way to the head. The signal purity was highly satisfactory, although at the hip and third lumbar vertebra when adopting the toe-standing and lunge, some less satisfactory results were found—especially at 20 Hz and 30 Hz. Present data indicate that the long vibration platform can be used for exercise and health in a safe way, although its specific behaviours have to be taken into account in order to optimise its applicability.

11 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GFGerard Moras Feliu
Gerard Moras Feliu
JGJose Gisbert-Orozco
Jose Gisbert-Orozco
JGJacob Gonzalez
Jacob Gonzalez
JVJairo Vázquez-Guerrero
Jairo Vázquez-Guerrero
SRSergio Rodríguez-Jiménez
Sergio Rodríguez-Jiménez
Bruno Fernández-ValdésBruno Fernández-Valdés
Bruno Fernández-Valdés
Hip range of movement (ROM) impairments could affect individuals’ quality of life. The aim of this study is to describe a new flexometric method (FM) as a means to estimate hip ROM and to determine its concurrent validity and inter-rater and intra-rater reliability. Hip ROM was measured by performing the straight leg raise test (SLR) and hip abduction test (HA). The WIMU system is the gold standard. ROM was calculated in degrees using a trigonometric function based on values derived from measurements with a flexometer. The SLR and the HA showed high concurrent validity and good inter- and intra-rater reliability with an interclass correlation coefficient value that was at all times > 0.9. The minimal detectable change at the 90% confidence level for inter- and intra-rater reliability was equal to or greater than 5.7° in SLR-Right, 5.6° in SLR-Left, 5.1° in HA, 6.3° in SLR-Right, 4.9° in SLR-Left, and 5.4° in HA, respectively. This study suggests that the FM is a valid and reliable tool for assessing hip ROM. Due to its convenience and cost-effectiveness, this method could be widely used to measure the ROM of several joints in field-based tests.