Wind energy is a prominent area of application of variable-speed generators operating on the constant grid frequency. This paper describes the operation and control of one of these variable-speed wind generators: the direct driven permanent magnet synchronous generator (PMSG). This generator is connected to the power network by means of a fully controlled frequency converter, which consists of a pulsewidth-modulation (PWM) rectifier, an intermediate dc circuit, and a PWM inverter. The generator is controlled to obtain maximum power from the incident wind with maximum efficiency under different load conditions. Vector control of the grid-side inverter allows power factor regulation of the windmill. This paper shows the dynamic performance of the complete system. Different experimental tests in a 3-kW prototype have been carried out to verify the benefits of the proposed system.
7 August 2002 in IEEE Transactions on Energy Conversion
Wind farms are considered to be negative loads from the point of view of a utility manager. Modern variable-speed wind turbines offer the possibility for controlling active and reactive power separately. This paper presents a new integrated control system of a wind farm according to the utility manager's requirements. This control system is based on two control levels: a supervisory system controls active and reactive power of the whole wind farm by sending out set points to all wind turbines, and a machine control system ensures that set points at the wind turbine level are reached. The system has been validated by numerical simulation using data from a wind farm with 37 variable-speed wind turbine situated in the North of Spain. An automatic generation control of these characteristics promises improved performance of the system and a better grid integration of the wind energy without significant extra costs.
This paper analyzes the effects of unbalanced voltage on doubly fed induction generators. It also presents a novel control strategy based on direct power control (DPC+) applied to this type of generators, predominant in wind energy applications, that enables them to work under perturbed conditions and achieve optimum results. Although the technique can be implemented to control both rotor converters and grid converters, we will hereby exemplify the former which regulates stator active and reactive power. The results obtained with DPC+ are then compared through experimental tests to indicate that the technique is suitable and achieves good dynamic responses while controlling current distortion, power or torque oscillations. The validation of results has been performed through experimental tests on a 20-kW generator.
12 April 2010 in IEEE Transactions on Industrial Electronics
Improving the fault ride-through (FRT) capability of doubly fed induction generators (DFIGs) in wind power applications is a very important challenge for the wind power industry. The mathematical models of such generators enable us to analyze their response under generic conditions. However, their mathematical complexity does not contribute to simplifying the analysis of the system under transient conditions and hence does not help in finding straightforward solutions for enhancing their FRT. This paper presents a simplified model of the DFIG, which has been extracted from the classical fifth-order model, which can accurately estimate the behavior of the system while significantly reducing its complexity. In this paper, the mathematical deduction of this model will be presented, and simulations and experimental results will be shown to demonstrate the accuracy and reliability of the proposed algorithm.
A new approach of direct power control (DPC) of a voltage source inverter for achieving symmetrical grid currents under unbalanced grid voltage conditions is presented. In these situations, negative sequence components appear on the grid voltage vector, leading to distorted currents if the power is maintained constant. Nevertheless, sinusoidal balanced grid currents can be achieved through control. Several current controllers have already been modified to overcome voltage imbalance with good results. Here, sinusoidal grid currents are obtained by directly controlling power, which becomes a novel approach and keeps DPC philosophy. A phase locked loop is necessary to obtain positive sequence voltage angle. A very simple positive and negative sequence calculator is also used so that power references can be modified in order to obtain balanced grid currents. Simulated and experimental results are presented to confirm the validity of the method.