Christopher R Butson

Prof. Christopher R Butson


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in NeuroImage
Verified
Journal Article
Closed access
CBChristopher R Butson
Christopher R Butson
SCScott E. Cooper
Scott E. Cooper
JHJaimie M. Henderson
Jaimie M. Henderson
CMCameron C. McIntyre
Cameron C. McIntyre

1 February 2006 in Clinical Neurophysiology
Verified
Journal Article
Closed access
CBChristopher R Butson
Christopher R Butson
CMChristopher B. Maks
Christopher B. Maks
CMCameron C. McIntyre
Cameron C. McIntyre

1 October 2005 in Clinical Neurophysiology
Verified
Journal Article
Closed access
CBChristopher R Butson
Christopher R Butson
CMCameron C. McIntyre
Cameron C. McIntyre

1 September 2006 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
SMSvjetlana Miocinovic
Svjetlana Miocinovic
MPMartin Parent
Martin Parent
CBChristopher R Butson
Christopher R Butson
PHPhilip J. Hahn
Philip J. Hahn
GRGary S. Russo
Gary S. Russo
CMCameron C. McIntyre
Cameron C. McIntyre
The subthalamic nucleus (STN) is the most common target for the treatment of Parkinson’s disease (PD) with deep brain stimulation (DBS). DBS of the globus pallidus internus (GPi) is also effective in the treatment of PD. The output fibers of the GPi that form the lenticular fasciculus pass in close proximity to STN DBS electrodes. In turn, both STN projection neurons and GPi fibers of passage represent possible therapeutic targets of DBS in the STN region. We built a comprehensive computational model of STN DBS in parkinsonian macaques to study the effects of stimulation in a controlled environment. The model consisted of three fundamental components: 1) a three-dimensional (3D) anatomical model of the macaque basal ganglia, 2) a finite element model of the DBS electrode and electric field transmitted to the tissue medium, and 3) multicompartment biophysical models of STN projection neurons, GPi fibers of passage, and internal capsule fibers of passage. Populations of neurons were positioned within the 3D anatomical model. Neurons were stimulated with electrode positions and stimulation parameters defined as clinically effective in two parkinsonian monkeys. The model predicted axonal activation of STN neurons and GPi fibers during STN DBS. Model predictions regarding the degree of GPi fiber activation matched well with experimental recordings in both monkeys. Only axonal activation of the STN neurons showed a statistically significant increase in both monkeys when comparing clinically effective and ineffective stimulation. Nonetheless, both neural targets may play important roles in the therapeutic mechanisms of STN DBS.

19 December 2005 in Journal of Neural Engineering
Verified
Journal Article
Closed access
CBChristopher R Butson
Christopher R Butson
CMCameron C McIntyre
Cameron C McIntyre
Deep brain stimulation (DBS) is an established clinical treatment for a range of neurological disorders. Depending on the disease state of the patient, different anatomical structures such as the ventral intermediate nucleus of the thalamus (VIM), the subthalamic nucleus or the globus pallidus are targeted for stimulation. However, the same electrode design is currently used in nearly all DBS applications, even though substantial morphological and anatomical differences exist between the various target nuclei. The fundamental goal of this study was to develop a theoretical understanding of the impact of changes in the DBS electrode contact geometry on the volume of tissue activated (VTA) during stimulation. Finite element models of the electrodes and surrounding medium were coupled to cable models of myelinated axons to predict the VTA as a function of stimulation parameter settings and electrode design. Clinical DBS electrodes have cylindrical contacts 1.27 mm in diameter (d) and 1.5 mm in height (h). Our results show that changes in contact height and diameter can substantially modulate the size and shape of the VTA, even when contact surface area is preserved. Electrode designs with a low aspect ratio (d/h) maximize the VTA by providing greater spread of the stimulation parallel to the electrode shaft without sacrificing lateral spread. The results of this study provide the foundation necessary to customize electrode design and VTA shape for specific anatomical targets, and an example is presented for the VIM. A range of opportunities exist to engineer DBS systems to maximize stimulation of the target area while minimizing stimulation of non-target areas. Therefore, it may be possible to improve therapeutic benefit and minimize side effects from DBS with the design of target-specific electrodes.

1 January 2008 in Brain Stimulation
Verified
Journal Article
Closed access
CBChristopher R Butson
Christopher R Butson
CMCameron C. McIntyre
Cameron C. McIntyre