Algimantas Bubulis

Prof. Dr. Algimantas Bubulis


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
VOVytautas Ostasevicius
Vytautas Ostasevicius
VJVytautas Jurėnas
Vytautas Jurėnas
SMSandra Mikuckyte
Sandra Mikuckyte
JVJoris Vezys
Joris Vezys
Edgaras StankeviciusEdgaras Stankevicius
Edgaras Stankevicius
LKLaura Kizauskiene
Laura Kizauskiene
The safety of ultrasound exposure is very important for a patient’s well-being. High-frequency (1–10 MHz) ultrasound waves are highly absorbed by biological tissue and have limited therapeutic effects on internal organs. This article presents the results of the development and application of a low-frequency (20–100 kHz) ultrasonic transducer for sonication of biological tissues. Using the methodology of digital twins, consisting of virtual and physical twins, an ultrasonic transducer has been developed that emits a focused ultrasound signal that penetrates into deeper biological tissues. For this purpose, the ring-shaped end surface of this transducer is excited not only by the main longitudinal vibrational mode, which is typical of the flat end surface transducers used to date, but also by higher mode radial vibrations. The virtual twin simulation shows that the acoustic signal emitted by the ring-shaped transducer, which is excited by a higher vibrational mode, is concentrated into a narrower and more precise acoustic wave that penetrates deeper into the biological tissue and affects only the part of the body to be treated, but not the whole body.

28 January 2026 in Animals
Verified
Journal Article
Open access
PDF file
Agne Paulauskaite-TarasevicieneAgne Paulauskaite-Taraseviciene
Agne Paulauskaite-Taraseviciene
ANArnas Nakrošis
Arnas Nakrošis
JZJudita Zymantiene
Judita Zymantiene
VJVytautas Jurėnas
Vytautas Jurėnas
JVJoris Vezys
Joris Vezys
VOVytautas Ostasevicius
Vytautas Ostasevicius
Digital technologies that continuously quantify animal behavior, physiology, and production offer significant potential for the early identification of health and welfare disorders of dairy cows. In this study, a multimodal artificial intelligence (AI) framework is proposed for real-time health monitoring of dairy cows through the integration of physiological, behavioral, production, and thermal imaging data, targeting veterinarian-confirmed udder, leg, and hoof infections. Predictions are generated at the cow-day level by aggregating multimodal measurements collected during daily milking events. The dataset comprised 88 lactating cows, including veterinarian-confirmed udder, leg, and hoof infections grouped under a single ‘sick’ label. To prevent information leakage, model evaluation was performed using a cow-level data split, ensuring that data from the same animal did not appear in both training and testing sets. The system is designed to detect early deviations from normal health trajectories prior to the appearance of overt clinical symptoms. All measurements, with the exception of the intra-ruminal bolus sensor, were obtained non-invasively within a commercial dairy farm equipped with automated milking and monitoring infrastructure. A key novelty of this work is the simultaneous integration of data from three independent sources: an automated milking system, a thermal imaging camera, and an intra-ruminal bolus sensor. A hybrid deep learning architecture is introduced that combines the core components of established models, including U-Net, O-Net, and ResNet, to exploit their complementary strengths for the analysis of dairy cow health states. The proposed multimodal approach achieved an overall accuracy of 91.62% and an AUC of 0.94 and improved classification performance by up to 3% compared with single-modality models, demonstrating enhanced robustness and sensitivity to early-stage disease.

28 June 2024 in Mechanics
Verified
Journal Article
Open access
PDF file
KRKazimieras Ragulskis
Kazimieras Ragulskis
ABAlgimantas Bubulis
Algimantas Bubulis
VJVytautas Jurėnas
Vytautas Jurėnas
JVJoris Vezys
Joris Vezys
PPPetras Paškevičius
Petras Paškevičius
LRLiutauras Ragulskis
Liutauras Ragulskis
Manipulators of this type can be used as constituent parts of robots of several dimensions. Vibration drive based on centrifugal forces is often used in elements of manipulators and robots. In this paper manipulator with vibration drive based on centrifugal forces and with the self-stopping mechanism is investigated. The model of the investigated manipulator is described and equations determining the motion of the manipulator are obtained. The conservative system is investigated. Then the full dynamic model is investigated. Also, the model with excitation of unlimited power is investigated. Numerical solution of the obtained equations is performed. First the results for the conservative system are described and investigated. Then the full dynamic model is investigated in detail. Also, the model with excitation of unlimited power is described and investigated. Various typical graphical relationships determining the dynamic behavior of the investigated manipulator with vibration drive based on centrifugal forces in steady state regimes of motion are presented. Experimental investigations are performed. The obtained results are used in the process of design of manipulators with vibration drive based on centrifugal forces.

21 February 2024 in Biomolecules
Verified
Journal Article
Open access
PDF file
ATAgilė Tunaitytė
Agilė Tunaitytė
SASilvijus Abramavicius
Silvijus Abramavicius
AVAugusta Volkevičiūtė
Augusta Volkevičiūtė
MVMantas Venslauskas
Mantas Venslauskas
ABAlgimantas Bubulis
Algimantas Bubulis
Edgaras StankeviciusEdgaras Stankevicius
Edgaras Stankevicius
The present study aimed to investigate the effect of a H2S donor, GYY 4137, on human pulmonary arteries and whether low-frequency ultrasound (20 kHz, 4 W/cm2) inhibits GYY 4137 contractions. Functional studies were conducted on human and rat pulmonary arteries mounted on microvascular myographs. We placed an ultrasonic gadget in the tissue organ bath to insonate the arteries with low-frequency ultrasound. To measure the effect of the low-frequency ultrasound on the entrance of extracellular Ca2+, the preparations were placed in a Ca2+-free solution, and the thromboxane agonist, U46619, and extracellular calcium were added in the presence of insonation. In isolated human pulmonary arteries, GYY 4137 induced contractions, which were most pronounced in the arteries contracted with the thromboxane analogue, U46619. The transient GYY4137 contractions were reversed by low-frequency ultrasound, a blocker of KV7 channels, XE-991 (10 µM), and glibenclamide (1 μM), a blocker of ATP-sensitive channels. Low-frequency ultrasound also inhibited the contractions induced by the smooth muscle entrance of increasing extracellular calcium concentrations. The present findings show that GYY 4137 can cause a transient contraction of pulmonary arteries in human arteries. GYY 4137 alone does not cause significant vascular contraction in rat lung arteries, but it contracts rat lung arteries precontracted with U46619. The transient contractions induced by GYY 4137 can be inhibited by low-frequency ultrasound, probably by counteracting the influx of external Ca2+. The effect of low-frequency ultrasound counteracts contraction in pulmonary arteries; therefore, a possibility could be to develop a larger device allowing treatment of patients with pulmonary hypertension.

26 February 2018 in Mechanics
Verified
Journal Article
Closed access
PDF file
SHSerhiy Horiashchenko
Serhiy Horiashchenko
IGIevgeniia Golinka
Ievgeniia Golinka
ABAlgimantas Bubulis
Algimantas Bubulis
VJVytautas Jurėnas
Vytautas Jurėnas
Simulation and Research of the Nozzle with an Ultrasonic Resonator for Spraying Polymeric Materials

31 December 2017 in Mathematical Models in Engineering
Verified
Journal Article
Open access
KRK. Ragulskis
K. Ragulskis
PPP. Paškevičius
P. Paškevičius
ABAlgimantas Bubulis
Algimantas Bubulis
APA. Pauliukas
A. Pauliukas
LRL. Ragulskis
L. Ragulskis
In the numerical investigation of vibration problems with dry friction it is accepted to use some type of approximation to this phenomenon. Often linear variation of the force of friction in a region around zero velocity is assumed. In this paper trigonometric variation is proposed and comparison of numerical results is performed. From the presented results higher precision of this approximation is observed.