To study on relationship between dynamic shear modulus and damping ratio with shear strain, a new dynamic-triaxial test is performed on sandy silt in Beijing area. The testing data of the dynamic-shear modulus are compared with the existing statistical data in Beijing area and the statistical curve to prove the rationality of the test results. Comparsion presents a good agreement.
The real-time input of ground motions can effectively assess earthquake disasters in building structures. In this study, we proposed a nearby real-time simulation method that can be applied to assess regional earthquake disasters using structural monitoring recordings based on an urban earthquake simulation system. Real-time accelerations recorded during the 5.1 magnitude Tangshan earthquake were used to update and modify the computing models. El Centro waves were calibrated to 400 cm/s2 for structural seismic resilience analyses. The results indicated that approximately 70% of the structural functions were lost during the rare earthquake. Regional numerical models of 216 buildings were constructed and timeously updated using a geographic information system and measured data. The inputting ground motions recorded in the 5.1 magnitude Tangshan earthquake and typical El Centro waves were selected to analyze the structural seismic response, in which the damage indexes were computed, and the damage predictions of the regional 216 buildings were also simulated in different levels of earthquakes by being combined with the simplified principles of structural damage estimation. Finally, the evaluation results were visualized in three dimensions using ParaView software. The simulated results of earthquake disasters at an urban scale will promote the prediction abilities of local earthquake administration agencies and have considerable potential to provide essential information for emergency responses and regional disaster mitigation.
The real-time input of ground motions can effectively assess earthquake disasters in building structures. In this study, we proposed a nearby real-time simulation method that can be applied to assess regional earthquake disasters using structural monitoring recordings based on an urban earthquake simulation system. Real-time accelerations recorded during the 5.1 magnitude Tangshan earthquake were used to update and modify the computing models. El Centro waves were calibrated to 400 cm/s2 for structural seismic resilience analyses. The results indicated that approximately 70% of the structural functions were lost during rare earthquakes. Regional numerical models of 216 buildings were constructed and timeously updated using the Geographic Information System and measured data. The inputting ground motions recorded in the 5.1 magnitude Tangshan earthquake and typical El Centro waves were selected to analyze the structural seismic response, in which the damage indexes were computed, and the damage predictions of regional 216 buildings were also simulated in different levels of earthquakes by being combined with the simplified principles of structural damage estimation. Finally, the evaluation results were visualized in three dimensions using ParaView software. The simulated results of earthquake disasters at an urban scale will promote the prediction abilities of local earthquake administration agencies and have considerable potential to provide essential information for emergency responses and regional disaster mitigation.
Analysis of wave propagation within buildings in response to earthquakes enables the tracking of changes in dynamic characteristics using impulse response functions. The velocity of traveling shear waves and the intrinsic attenuation of buildings can be retrieved, providing valuable input for system identification. The Factor Building at the University of California, Los Angeles campus (henceforth referred to as the UCLA Factor Building), an instrumented 15-story steel moment frame structure, is selected for dynamic response characterization. Shear wave travel time and attenuation are computed from wave propagation using seismic interferometry applied to recorded motions, with deconvolved waves used to compute these parameters. In this study, the natural logarithm of the envelopes of waveforms deconvolved with the basement signal provided the measure of attenuation. Additionally, the waveforms deconvolved with the basement motion, indicating the building’s fundamental mode. The frequency and time decay further constrained the shear velocity and attenuation. Shear velocity was determined using arrival times measured from deconvolved waves, resulting in an average velocity of 147.1 m/s. The observed quality factor was 10.8, with a corresponding damping ratio of 5%. The shear wave velocity and damping ratio estimates derived from deconvolved waves showed consistency with those obtained from basement deconvolved waveforms. This consistency validates wave deconvolution as an effective method for isolating building response from excitation and ground coupling. By incorporating the resonant frequencies and damping ratios derived from previous analyses into a refined element model, this study underscores the potential of wave deconvolution for extracting building dynamic characteristics, thereby enhancing our understanding of their responses to earthquakes.
Ambient dynamic test is applied to a 3-story building in Beijing and system identification is adopted to obtain the natural dynamic characteristics. The amplitudes of time histories recorded by different seismometers are compared. They increase with the floor number and two horizontal amplitudes are larger than the vertical one. Spectra analysis indicates that the spectra values of the recordings on the third floor are bigger than lower floors and Fourier spectra for vertical signals are relatively clearer and more remarkable than two horizontal recordings. Analysis suggests that ambient test is a useful tool for structural system identification.
To achieve rapid post-earthquake repair of self-centering ribbed floor flat-beam frame structures, a ductile hybrid joint consisting of dog-bone-shaped, weakened, energy-dissipating steel bars connected to the upper and lower column sections through high-strength threads is proposed based on the damage control design concept. By moving the ductile energy-dissipating zone out to the locally weakened section of the energy-dissipating steel bars and the locally unbonded prestressed steel bars in the core area, the residual deformation was limited and the seismic performance improved. Based on the working principle of hybrid joints, low cycle loading tests were conducted on two joint specimens to analyze the influence of lateral prestress on the seismic performance of the hybrid joints. Numerical modeling methods were used to compare the position of the energy-dissipating steel bars in the composite layer and the friction performance of the joints. The research results indicated that the hybrid joint had stable load bearing, deformation, and energy dissipation capabilities, with damage being primarily concentrated in the energy-dissipating steel bars. Even at an inter-story displacement angle of 5.5%, the upper and lower column segments remained elastic. After unloading, the connection seam at the joint was closed, and the self-centering performance was good. When the inter-story displacement angle reached 5.5%, the lateral prestress increased from 150 kN to 250 kN, the ultimate bearing capacity of the joint increased by 16.3%, and the cumulative energy consumption increased by 30.0%. The influence of the friction coefficient of the joint surface on the structural performance was set at a threshold of 0.7. When it was less than the threshold, the ultimate bearing capacity and initial stiffness of the joint increased with the increase in the friction coefficient. After reaching the threshold, the increase in the ultimate bearing capacity of the joint slowed down, and the rate of stiffness degradation gradually accelerated. This joint showed excellent seismic performance and can thus achieve post-earthquake repair of structures.