Huanhuan Wang

Prof. Dr. Huanhuan Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2023 in Chemosphere
Verified
Journal Article
Closed access
SZShaocheng Zhang
Shaocheng Zhang
JHJuan Hu
Juan Hu
GXGuangjun Xiao
Guangjun Xiao
SCShu Chen
Shu Chen
HWHuanhuan Wang
Huanhuan Wang

24 May 2025 in Accreditation and Quality Assurance
Verified
Journal Article
Closed access
PDF file
GXGuangjun Xiao
Guangjun Xiao
JHJuan Hu
Juan Hu
YLYanting Liu
Yanting Liu
YWYutao Wang
Yutao Wang
HWHuanhuan Wang
Huanhuan Wang
SZShaocheng Zhang
Shaocheng Zhang

17 March 2025 in Frontiers of Environmental Science & Engineering
Verified
Journal Article
Closed access
PDF file
SZShaocheng Zhang
Shaocheng Zhang
XZXi Zhan
Xi Zhan
JWJing Wang
Jing Wang
HXHanhan Xie
Hanhan Xie
HQHui Quan
Hui Quan
HWHuanhuan Wang
Huanhuan Wang

15 February 2026 in Journal of Microbiological Methods
Verified
Journal Article
Closed access
GLGuijuan Liao
Guijuan Liao
XWXiaoli Wu
Xiaoli Wu
HWHuanhuan Wang
Huanhuan Wang
QCQingyun Chen
Qingyun Chen
HQHui Quan
Hui Quan
SZShaocheng Zhang
Shaocheng Zhang

16 March 2026 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
GXGuangjun Xiao
Guangjun Xiao
YLYanting Liu
Yanting Liu
JHJuan Hu
Juan Hu
BPBin Peng
Bin Peng
WLWeifeng Liao
Weifeng Liao
SZShaocheng Zhang
Shaocheng Zhang
Analogous to medication dosage errors, inaccuracies in measurement units for analyte test results in clinical laboratories can lead to adverse clinical consequences. We report a case of a 35-years-old pregnant woman at 38 weeks of gestation with a history of gestational hypertension. During routine follow-up, she presented with elevated blood pressure, abnormal qualitative urinary protein findings, and an elevated random urinary protein concentration, prompting a request for 24-hour urinary total protein quantification (UTP). The laboratory reported her 24-hour urine total protein excretion as 547.87 g/24 h, which the attending physician identified as inconsistent with the patient’s clinical manifestations. Unfortunately, the medical laboratory professional failed to identify the cause of the discrepancy following receipt of the feedback and only reported the issue to the laboratory quality supervisor 1 week later. In the detection system, both the direct and 1:2 auto-diluted measurements triggered an “F” alarm code, indicating the analyte concentration exceeded the analytical measurement range. When the alarm code in the data flag column and the analyte measurement result were simultaneously transmitted to the Laboratory Information System (LIS), precluding accurate data recognition and extraction by the LIS. This led to the appearance of the alarm code in the LIS result field and disrupted the automatic unit conversion process. According to relevant requirements (such as those in the detection system operation manual or the laboratory-developed standard operating procedure), if the alarm code appears in the data flag column of the measurement result, it is necessary to further increase the dilution ratio and conduct a re-measurement. Regrettably, the alarm code was mishandled in the laboratory: it was manually suppressed in the LIS. This resulted in the failure of the automatic unit conversion, leading to a 100-fold overestimation as the results were erroneously reported in “g/L” instead of mg/dL.” This case highlights critical quality management considerations for other clinical laboratories, emphasizing the importance of unit consistency across diverse detection platforms and information systems, and the quality risks associated with falsely decreased results when analyzing high-concentration samples.

21 August 2025 in Biological Trace Element Research
Verified
Journal Article
Closed access
PDF file
FZFan Zhong
Fan Zhong
JWJing Wang
Jing Wang
XCXi Chen
Xi Chen
GXGuangsu Xie
Guangsu Xie
HWHuanhuan Wang
Huanhuan Wang
SZShaocheng Zhang
Shaocheng Zhang