In this study, electrochemical modification of a glassy carbon (GC) electrode with apigenin was carried out and the modified electrode was used for determination of copper(II) (Cu(II)) in soil samples. The GC was modified through the electrochemical polymerization of apigenin (PolyApi/GC) on the electrode surface in aqueous media. The electrode surface was modified with apigenin in phosphate buffer solution (PBS), pH 7, from 0 mV to +1400 mV potential ranges, using 100 mV s−1 sweep rate and 30 cycles by cyclic voltammetry (CV). The surface characterizations of this sensor electrode were performed by CV, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). Britton-Robinson (BR) buffer solution at pH 5 was used for determination of Cu(II) by differential pulse voltammetry (DPV). The detection limit was obtained as lower as 1.0 × 10−11 M. By using this calibration curve, the amount of Cu(II) was determined as 7.34 × 10−7 M in soil samples. The results showed that pH, incubation time and interferences of some cations and anions were significant.
Electrochemical oxidation of quercetin, as an important biological molecule, has been studied in non-aqueous media using cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. To investigate the electrochemical properties of quercetin, an important flavonoid derivative, on a different surface, a new glassy carbon electrode has been developed using dithiooxamide as modifier in non-aqueous media. The surface modification of glassy carbon electrode has been performed within the 0.0 mV and +800 mV potential range with 20 cycles using 1 mM dithioxamide solution in acetonitrile. However, the modification of quercetin to both bare glassy carbon and dithiooxamide modified glassy carbon electrode surface was carried out in a wide +300 mV and +2,800 mV potential range with 10 cycles. Following the modification process, cyclic voltammetry has been used for the surface characterization in aqueous and non-aqueous media whereas electrochemical impedance spectroscopy has been used in aqueous media. Scanning electron microscopy has also been used to support the surface analysis. The obtained data from the characterization and modification studies of dithioxamide modified and quercetin grafted glassy carbon electrode showed that the developed electrode can be used for the quantitative determination of quercetin and antioxidant capacity determination as a chemical sensor electrode.
Electrochemical modification of glassy carbon (GC) electrode by naringenin (NG), a fl avonoid derivative, and applicability of electrode modified in this way for determination of copper(II) (Cu(II)) ions is reported in this study. Surface modification experiments were performed in phosphate buffer solution (PBS), pH 7, in the 0.0 mV and +1400 mV potential ranges with a sweep rate of 100 mV s–1 and 30 cycles. The surface modification of GC electrode was performed with NG using cyclic voltammetry (CV), whereas the characterization of this sensor electrode was performed using CV and electrochemical impedance spectroscopy (EIS). The sensitivity of GC electrode modified in described way towards Cu(II) ions was investigated in Britton–Robinson (BR) buffer solution, pH 5, by differential pulse voltammetry (DPV). For the calibration curve, a series of standard Cu(II) solution from 1.0 × 10−12 M to 1.0 × 10−6 M was prepared. The NG modified GC (NG/GC) sensor electrode, has a good repeatability, was applied for Cu(II) ions determination in Beyşehir lake (in Konya, Turkey) water sample. Detection limit was obtained as lower as 1.0 × 10−12 M. The proposed method was simple, rapid, low cost and sensitive for the determination of Cu(II) ions.