Objectives: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections cause coronavirus disease 2019 (COVID-19) and induce a specific antibody response. Serological assays detecting IgG against the receptor binding domain (RBD) of the spike (S) protein are useful to monitor the immune response after infection or vaccination. The objective of our study was to evaluate the clinical performance of the Siemens SARS-CoV-2 IgG (sCOVG) assay. Methods: Sensitivity and specificity of the Siemens sCOVG test were evaluated on 178 patients with SARS-CoV-2-infection and 160 pre-pandemic samples in comparison with its predecessor test COV2G. Furthermore, correlation with virus neutralization titers was investigated on 134 samples of convalescent COVID-19 patients. Results: Specificity of the sCOVG test was 99.4% and sensitivity was 90.5% (COV2G assay 78.7%; p<0.0001). S1-RBD antibody levels showed a good correlation with virus neutralization titers (r=0.843; p<0.0001) and an overall qualitative agreement of 98.5%. Finally, median S1-RBD IgG levels increase with age and were significantly higher in hospitalized COVID-19 patients (median levels general ward: 25.7 U/mL; intensive care: 59.5 U/mL) than in outpatients (3.8 U/mL; p<0.0001). Conclusions: Performance characteristics of the sCOVG assay have been improved compared to the predecessor test COV2G. Quantitative SARS-CoV-2 S1-RBD IgG levels could be used as a surrogate for virus neutralization capacity. Further harmonization of antibody quantification might assist to monitor the humoral immune response after COVID-19 disease or vaccination.
15 January 2021 in Clinical Chemistry and Laboratory Medicine (CCLM)
Objectives: Serological tests detect antibodies against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in the ongoing coronavirus disease-19 (COVID-19) pandemic. Independent external clinical validation of performance characteristics is of paramount importance. Methods: Four fully automated assays, Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, Siemens SARS-CoV-2 total (COV2T) and SARS-CoV-2 IgG (COV2G) were evaluated using 350 pre-pandemic samples and 700 samples from 245 COVID-19 patients (158 hospitalized, 87 outpatients). Results: All tests showed very high diagnostic specificity. Sensitivities in samples collected at least 14 days after disease onset were slightly lower than manufacturers’ claims for Roche (93.0%), Abbott (90.8%), and Siemens COV2T (90.3%), and distinctly lower for Siemens COV2G (78.8%). Concordantly negative results were enriched for immunocompromised patients. ROC curve analyses suggest a lowering of the cut-off index for the Siemens COV2G assay. Finally, the combination of two anti-SARS-CoV-2 antibody assays is feasible when considering borderline reactive results. Conclusions: Thorough on-site evaluation of commercially available serologic tests for detection of antibodies against SARS-CoV-2 remains imperative for laboratories. The potentially impaired sensitivity of the Siemens COV2G necessitates a switch to the company’s newly filed SARS-CoV-2 IgG assay for follow-up studies. A combination of tests could be considered in clinical practice.
Objective: To report outcomes from routine clinical practice of liver transplantation (LT) following normothermic liver machine perfusion (NLMP) and compare to LT after static cold storage (SCS). Background: NLMP is emerging as a clinical routine in LT and has recently received renewed attention; however, outcomes outside of clinical trials are lacking. Methods: All adult LT between February 2018 and January 2023 were included. A comprehensive viability assessment was applied during NLMP. Outcomes were compared between NLMP and SCS recipients, as well as benchmark and non-benchmark cases. Results: Of the 332 LT included, 174 underwent NLMP and 158 were transplanted after SCS. Sixty-seven organs were accepted and transplanted only under the premise of NLMP. One-year graft survival for SCS and NLMP recipients was 83.8% versus 81.3% and 93.4% for benchmark cases in the overall cohort. Total preservation time had no influence on graft survival in the NLMP group but was associated with inferior 1-year graft survival in the SCS group. NLMP usage increased significantly over the duration of the study period, as did the median total preservation time. With increasing NLMP use and longer preservation times, nighttime surgery decreased significantly from 41.9% to 4.2%. Conclusions: Prolonged preservation times ease logistics and enable daytime surgery. The possibility of NLMP offers to expand LT without negatively affecting outcomes.
The current study aims to evaluate whether prophylactic anticoagulation using argatroban or an increased dose of unfractionated heparin (UFH) is effective in achieving the targeted activated partial thromboplastin time (aPTT) of more than 45 s in critically ill heparin-resistant (HR) patients. Patients were randomized either to continue receiving an increased dose of UFH, or to be treated with argatroban. The endpoints were defined as achieving an aPTT target of more than 45 s at 7 h and 24 h. This clinical trial was registered on clinicaltrials.gov (NCT01734252) and on EudraCT (2012-000487-23). A total of 42 patients, 20 patients in the heparin and 22 in the argatroban group, were included. Of the patients with continued heparin treatment 55% achieved the target aPTT at 7 h, while only 40% of this group maintained the target aPTT after 24 h. Of the argatroban group 59% reached the target aPTT at 7 h, while at 24 h 86% of these patients maintained the targeted aPTT. Treatment success at 7 h did not differ between the groups (p = 0.1000), whereas at 24 h argatroban showed significantly greater efficacy (p = 0.0021) than did heparin. Argatroban also worked better in maintaining adequate anticoagulation in the further course of the study. There was no significant difference in the occurrence of bleeding or thromboembolic complications between the treatment groups. In the case of heparin-resistant critically ill patients, argatroban showed greater efficacy than did an increased dose of heparin in achieving adequate anticoagulation at 24 h and in maintaining the targeted aPTT goal throughout the treatment phase.
17 May 2023 in International Journal of Laboratory Hematology