Lihua Lei

Dr. Lihua Lei


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2015 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Closed access
GFGuofang Fan
Guofang Fan
RORegis Orobtchouk
Regis Orobtchouk
BHBing Han
Bing Han
YLyuan li
yuan li
CHChunguang Hu
Chunguang Hu
QWQi Wang
Qi Wang
Optical waveguides on three material platforms of silicon-on-insulator (SOI), amorphous silicon (a-Si:H) and silicon nitride are analyzed for realization of an optical compact link compatible with CMOS technology. The three material properties are presented. The optical components on the three potential material platforms are put together for a comparison, in which, straight, bent waveguides, and multimode-interference beam splitters for an optical link are designed, fabricated, and measured. The comparison results of simulation and measurement show that a-Si:H has a similar performances with SOI material but lower cost and good feasibility of photonic integration on silicon.

20 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
QZQilin Zeng
Qilin Zeng
ZZZhengyi Zhao
Zhengyi Zhao
XXXianming Xiong
Xianming Xiong
HDHao Du
Hao Du
WZWentao Zhang
Wentao Zhang
LLLihua Lei
Lihua Lei
In this study, a subnanometer heterodyne interference signal processing algorithm with a dynamic filter is proposed. The algorithm can effectively reduce the measurement error caused by the noise introduced in the optical path and circuit. Because of the low signal−to−noise ratio of the measurement signal, a dynamic filter with variable coefficients is designed. The role of the bi−quadrature lock−in amplifier algorithm in the problem of different amplitudes among the measurement signal, reference signal, and uncertainty of the frequency difference of the dual−frequency laser is analyzed. With the aid of the heterodyne interferometry platform, the error in the solution results of the proposed algorithm and the conventional algorithm is compared. The results indicate that the maximum deviation of the phase increment of the algorithm does not exceed 6 mrad, the single−cycle phase difference can be subdivided by 1024, and the system resolution reaches 0.15 nm.

17 September 2022 in Photonics
Verified
Journal Article
Open access
PDF file
ZWZiruo Wu
Ziruo Wu
YXYingfan Xiong
Yingfan Xiong
LLLihua Lei
Lihua Lei
WTWen Tan
Wen Tan
ZTZhaohui Tang
Zhaohui Tang
TLTongbao Li
Tongbao Li
Atomic force microscope (AFM) is commonly used for three-dimensional characterization of the surface morphology of structures at nanoscale, but the “Inflation effect” of the tip is an important factor affecting the accuracy. A tip characterizer has the advantages of in situ measurement, higher accuracy of probe inversion results, and relatively simple fabrication process. In this paper, we developed a rectangular tip characterizer based on multilayer film deposition technology with protruding critical dimension parts and grooves parts. And the tip characterization is highly consistent across the line widths and grooves, and still performs well even in the sub-5 nm line width tip characterizer. This indicates that tip characterizers produced by this method can synergistically meet the combined requirements of standard rectangular structure, very small line edge roughness, very small geometry dimension, and traceable measurements.

30 October 2014 in Sensors
Verified
Journal Article
Open access
PDF file
JWJunjie Wu
Junjie Wu
LLLihua Lei
Lihua Lei
Xin CHENGXin CHENG
Xin CHENG
XCXiaoyu Cai
Xiaoyu Cai
YLyuan li
yuan li
THTao Han
Tao Han
For the dimensional measurement and characterization of microsized and nanosized components, a three-dimensional microdisplacement sensing system was developed using the piezoresistive effect in silicon. The sensor was fabricated using microelectromechanical system bulk-silicon technology, and it was validated using the finite element method. A precise data acquisition circuit with an accuracy of 20 μV was designed to obtain weak voltage signals. By calibration, the sensing system was shown to have a sensitivity of 17.29 mV/μm and 4.59 mV/μm in the axial and lateral directions, respectively; the nonlinearity in these directions was 0.8% and 1.0% full scale, respectively. A full range of 4.6 μm was achieved in the axial direction. Results of a resolution test indicated that the sensing system had a resolution of 5 nm in the axial direction and 10 nm in the lateral direction.

17 November 2023 in Photonics
Verified
Journal Article
Open access
PDF file
YXYingfan Xiong
Yingfan Xiong
JGJinming Gou
Jinming Gou
ZTZhaohui Tang
Zhaohui Tang
GXGuangxu Xiao
Guangxu Xiao
LLLihua Lei
Lihua Lei
Xinbin ChengXinbin Cheng
Xinbin Cheng
The characterization of scanning tip morphology is crucial for accurate linewidth measurements. Conventional rectangular characterizers are affected by lateral distortion caused by the nonlinearities in AFM scanning, leading to errors between the actual characterization results and the true values. In this study, we innovatively developed self-traceable two-dimensional nano-gratings using chromium atomic deposition technology and extreme ultraviolet interference lithography. We used this structure as a characterizer for conducting scanning tip characterizations.This paper analyzed the periodic stability of the grating sample during scanning and corrected the lateral distortion of atomic force microscopy (AFM) at scan scales of 0.5 µm and 1 µm based on its self-traceable characteristics. Additionally, we extracted the angle information of the scanning tip in the X direction and Y direction within a scan scale of 0.5 µm. The results demonstrate that the two-dimensional grating sample exhibited excellent periodic stability during scanning. The characterization errors for the tip’s X direction and Y direction angles are within ±2°, showing high consistency. This study highlights that self-traceable two-dimensional grating samples have the capability for in situ bidirectional characterization of tip information, providing a creative solution for the development of new-style tip characterizers.

25 August 2023 in Applied Optics
Verified
Journal Article
Closed access
TJTao Jin
Tao Jin
GLGuanglin Li
Guanglin Li
LLLihua Lei
Lihua Lei
Eye movement research is an established methodology and widely used in fundamental research fields such as psychology or neuroscience. Most research is performed in controlled environments with screen-based eye trackers, but demand for a wearable requirement is on the rise. Yet, a state of the art wearable eye tracking system thus far has not been feasible for subjects with refractive errors; therefore, a trial frame is proposed for researching the eye movement of people with or without refractive errors. Two iris cameras and several infrared radiation LEDs were fixed behind the frame for recording eye images. The images were sent to a host computer using 2.4G wireless, which was also fixed on the frame. The entire electronic system in the trial frame was driven using a battery. Eye position in the images was recognized and segmented by a model that was trained through machine learning. Then the pupil and blinks were detected from the segmented eye area using ellipse fitting and the eye aspect ratio. Experiments showed that the correct rate of pupil and blink detections were 97.24% and 96.14%, respectively. (c) 2023 Optica Publishing Group