Victor de Haan

Dr. Victor de Haan

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2007 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
VHVictor de Haan
Victor de Haan
JPJeroen Plomp
Jeroen Plomp
WBWim G. Bouwman
Wim G. Bouwman
MTMartin Trinker
Martin Trinker
MRM. Theo Rekveldt
M. Theo Rekveldt
AWAd A. van Well
Ad A. van Well

9 June 2020 in Physical Review D
Verified
Journal Article
Closed access
PDF file
SPS. R. Parnell
S. R. Parnell
AWA. A. van Well
A. A. van Well
JPJ. Plomp
J. Plomp
RDR. M. Dalgliesh
R. M. Dalgliesh
NSN.-J. Steinke
N.-J. Steinke
VHVictor de Haan
Victor de Haan
Various theories beyond the Standard Model predict new particles with masses in the sub-eV range with very weak couplings to ordinary matter which can possess spin-dependent couplings to electrons and nucleons. We report null results of a search for possible exotic spin-dependent couplings of the neutron which could be induced by the exchange of light weakly coupled bosons or spin-gravity coupling conducted using a spin-echo neutron spectrometer. We constrain the products gA2 and gAgV of the axial vector coupling of the neutron to the matter of the Earth through the exchange of a weakly coupled vector boson for force ranges between the metre scale and the radius of the Earth. We also constrain the constants in some theories of exotic spin-gravity couplings.

13 January 2025 in Physical Review Research
Verified
Journal Article
Open access
NGNiels Geerits
Niels Geerits
Stephan SponarStephan Sponar
Stephan Sponar
KSKyle E. Steffen
Kyle E. Steffen
WSWilliam Michael Snow
William Michael Snow
SPSteven R. Parnell
Steven R. Parnell
VHVictor de Haan
Victor de Haan
A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect.

5 March 2025 in Physical Review Letters
Verified
Journal Article
Closed access
SMS. McKay
S. McKay
VHVictor de Haan
Victor de Haan
JLJ. Leiner
J. Leiner
SPS. R. Parnell
S. R. Parnell
RDR. M. Dalgliesh
R. M. Dalgliesh
RPR. Pynn
R. Pynn
The Goos-Hänchen (GH) shift describes a phenomenon in which a specularly reflected beam is translated along the reflecting surface such that the incident and reflected rays no longer intersect at the surface. Using a neutron spin-echo technique and a specially designed magnetic multilayer mirror, we have measured the relative phase between the reflected up and down neutron spin states in total reflection. The relative GH shift calculated from this phase shows a strong resonant enhancement at a particular incident neutron wave vector, which is due to a waveguiding effect in one of the magnetic layers. Calculations based on the observed phase difference between the neutron states indicate a propagation distance along the waveguide layer of 0.65 mm for the spin-down state, which we identify with the magnitude of the giant GH shift. The existence of a physical GH shift is confirmed by the observation of neutron absorption in the waveguide layer. We propose ways in which our experimental method may be exploited for neutron quantum-enhanced sensing of thin magnetic layers.

23 March 2010 in Physical Review B
Verified
Journal Article
Closed access
VHVictor de Haan
Victor de Haan
JPJeroen Plomp
Jeroen Plomp
MRM. Theo Rekveldt
M. Theo Rekveldt
AWAd A. van Well
Ad A. van Well
RDRobert M. Dalgliesh
Robert M. Dalgliesh
RHRuud Hendrikx
Ruud Hendrikx
Based on the application of coherence theory to neutron scattering a description is given of the propagation of neutrons or x-rays through a reflectometer. Important coherence effects at the sample position are discussed. Further, an outline is given how to determine the measured count rate in a detector on the basis of this method including neutron-polarization effects. It is shown in what way the Born approximation and distorted-wave Born approximation can be used within this theory. An outline is given of the phase-object approximation, describing the specular and diffuse scattering from a surface with large surface structure, extending over the existing capabilities of the distorted-wave Born approximation. The incorporation of neutron-polarization effects enables the detailed discussion of neutron spin-echo coding techniques applied to reflectometry.

5 October 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
VHVictor de Haan
Victor de Haan
RSR. Santbergen
R. Santbergen
MTM. Tijssen
M. Tijssen
Miro ZemanMiro Zeman
Miro Zeman
A study is presented giving the response of three types of fiber-optic interferometers by which a standing wave through an object is investigated. The three types are a Sagnac, Mach–Zehnder and Michelson–Morley interferometer. The response of the Mach–Zehnder interferometer is similar to the Sagnac interferometer. However, the Sagnac interferometer is much harder to study because of the fact that one input port and output port coincide. Further, the Mach–Zehnder interferometer has the advantage that the output ports are symmetric, reducing the systematic effects. Examples of standing wave light absorption in several simple objects are given. Attention is drawn to the influence of standing waves in fiber-optic interferometers with weak-absorbing layers incorporated. A method is described for how these can be theoretically analyzed and experimentally measured. Further experiments are needed for a thorough comparison between theory and experiment.