Boel Hansson

Dr. Boel Hansson

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
BHBoel Hansson
Boel Hansson
KBKarin Markenroth Bloch
Karin Markenroth Bloch
TOTitti Owman
Titti Owman
MNMarkus Nilsson
Markus Nilsson
JLJimmy Lätt
Jimmy Lätt
IBIsabella M. Björkman‐Burtscher
Isabella M. Björkman‐Burtscher
Background: Ultrahigh‐field (UHF) MRI advances towards clinical use. Patient compliance is generally high, but few large‐scale studies have investigated the effects experienced in 7T MRI systems, especially considering peripheral nerve stimulation (PNS) and caregiving.Purpose: To evaluate the quantity, the intensity, and subjective experiences from short‐term effects, focusing on the levels of comfort and compliance of subjects.Study Type: Prospective.Population: In all, 954 consecutive MRIs in 801 subjects for 3 years.Field Strength: 7T.Assessment: After the 7T examination, a questionnaire was used to collect data.Statistical Tests: Descriptive statistics, Spearman's rank correlation, Mann–Whitney U‐test, and t‐test.Results: The majority (63%) of subjects agreed that the MRI experience was comfortable and 93% would be willing to undergo future 7T MRI as a patient (5% undecided) and 82% for research purposes (12% undecided). The most common short‐term effects experienced were dizziness (81%), inconsistent movement (68%), PNS (63%), headache (40%), nausea (32%), metallic taste (12%), and light flashes (8%). Of the subjects who reported having PNS (n = 603), 44% experienced PNS as “not uncomfortable at all,” 45% as “little or very little uncomfortable,” and 11% as “moderate to very much uncomfortable.” Scanner room temperature was experienced more comfortable before (78%) than during (58%) examinations, and the noise level was acceptable by 90% of subjects. Anxiety before the examination was reported by 43%. Patients differed from healthy volunteers regarding an experience of headache, metallic taste, dizziness, or anxiety. Room for improvement was pointed out after 117 examinations concerning given information (n = 73), communication and sound system (n = 35), or nursing care (n = 15).Data Conclusion: Subjectively reported effects occur in actively shielded 7T MRI and include physiological responses and individual psychological issues. Although leaving room for improvement, few subjects experienced these effects being so uncomfortable that they would lead to aversion to future UHF examinations.Level of Evidence: 1Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2020;52:1265–1276.

28 March 2019 in Bioelectromagnetics
Verified
Journal Article
Open access
PDF file
BHBoel Hansson
Boel Hansson
PHPeter Höglund
Peter Höglund
KBKarin Markenroth Bloch
Karin Markenroth Bloch
MNMarkus Nilsson
Markus Nilsson
JOJohan Olsrud
Johan Olsrud
IBIsabella M. Björkman‐Burtscher
Isabella M. Björkman‐Burtscher
The objective of this study was to evaluate occurrence and strength of short‐term effects experienced by study participants in an actively shielded (AS) 7 tesla (7 T) magnetic resonance (MR) scanner, to compare results with earlier reports on passively shielded (PS) 7 T MR scanners, and to outline possible healthcare strategies to improve patient compliance. Study participants (n = 124) completed a web‐based questionnaire directly after being examined in an AS 7 T MR (n = 154 examinations). Most frequently experienced short‐term effects were dizziness (84%) and inconsistent movement (70%), especially while moving into or out of the magnet. Peripheral nerve stimulation (PNS)—twitching—was experienced in 67% of research examinations and showed a dependence between strength of twitches and recorded predicted PNS values. Of the participants, 74% experienced noise levels as acceptable and the majority experienced body and room temperature as comfortable. Of the study participants, 95% felt well‐informed and felt they had had good contact with the staff before the examination. Willingness to undergo a future 7 T examination was high (>90%). Our study concludes short‐term effects are often experienced during examinations in an AS 7 T MR, leaving room for improvement in nursing care strategies to increase patient compliance. Bioelectromagnetics. 2019;9999:XX–XX. © 2019 The Authors. Bioelectromagnetics Published by Wiley Periodicals, Inc.

13 December 2019 in European Radiology
Verified
Journal Article
Open access
PDF file
BHBoel Hansson
Boel Hansson
JOJohan Olsrud
Johan Olsrud
JWJonna Wilén
Jonna Wilén
TOTitti Owman
Titti Owman
PHPeter Höglund
Peter Höglund
IBIsabella M. Björkman-Burtscher
Isabella M. Björkman-Burtscher
Objectives: The objectives were to survey MR safety incidents in Sweden during a 12-month period, to assess severity scores, and to evaluate the confidence of MR personnel in incident-reporting mechanisms. Method: Data were collected within a web-based questionnaire on safety in clinical MR environments with CT for comparison. Data reported MR and CT safety incidents (human injury, material damage, and close calls), incident severity, and confidence of participants in incident-reporting systems. Results: The study population consisted of 529 eligible participants. Participants reported 200 MR and 156 CT safety incidents. Among MR incidents, 16% were given the highest potential severity score. More MR workers (73%) than CT workers (50%) were confident in being aware of any incident occurring at their workplace. However, 69% MR workers (83% for CT) were not aware of reported incidents at their hospitals. Conclusion: Safety incidents resulting in human injury, material damage, and close calls in clinical MR environments do occur. According to national risk assessment recommendations, risk level is high. Results indicated that MR personnel tend to a false sense of security, as a high proportion of staff members were sure that they would have been aware of any incident occurring in their own department, while in reality, incidents did occur without their knowledge. We conclude that false sense of security exists for MR. Key Points: • Safety incidents in clinical MR environments still result in human injury and material damage. • Severity level of MR incidents—assessed using Swedish national risk assessment recommendations—is high. • Confidence of MR personnel in incident-reporting mechanisms is high, but reflects a false sense of security, as a high proportion of staff is unaware of reported incidents in the same workplace.

20 August 2022 in Seizure: European Journal of Epilepsy
Verified
Journal Article
Open access
AZAriadne Zampeli
Ariadne Zampeli
BHBoel Hansson
Boel Hansson
KBKarin Markenroth Bloch
Karin Markenroth Bloch
EEElisabet Englund
Elisabet Englund
KKKristina Källén
Kristina Källén
IBIsabella M. Björkman-Burtscher
Isabella M. Björkman-Burtscher
To analyze structural characteristics of malformations of cortical development (MCD) at 7T and 3T MRI. Twenty-five patients were examined with a 7T MRI-scanner in addition to 3T examinations performed for epilepsy evaluation. 7T sequences included a 3D-T1-weighted (T1w) MPRAGE, 3D-T2w FLAIR, and heavily T2w axial and coronal high-resolution (0.5 × 0.5 × 0.75-1.0 mm3) 2D-TSE sequences. Images were reviewed for 7T MRI imaging characteristics of MCD, visibility and frequency of identified lesions on 7T and on 3T (original reports and second reading). In 25 patients 112 lesions were identified (57 gray matter (GM) heterotopia, 37 focal cortical dysplasia (FCD), and 18 other MCD). Imaging characteristics of the 37 FCD were cortical thickening (n = 11); GM-WM border blurring (n = 30); GM signal intensity changes (n = 18); juxtacortical WM signal intensity changes (n = 18); and transmantle WM signal intensity changes (n = 11). None of the 7T MRI sequences was sufficient to detect all types of lesions. Heterotopia were in general isointense to normal GM. Structural associations between 36 heterotopia and overlaying cortex were observed, composed either of a direct connection, vessel-like structures, or GM-like bridges. FCD were mentioned in 30% (11 of 37) of the original reports at 3T, and in 57% (21 of 37) after second reading. FCD connections to subcortical heterotopia were clinically not reported at all. 7T MRI revealed subtle connections between heterotopia and previous unidentified pathology in overlaying cortex. These findings may be significant for the understanding of the anatomical seizure origin and propagation pathways.

10 April 2024 in Radiography
Verified
Journal Article
Open access
AGA. Glans
A. Glans
JWJ. Wilén
J. Wilén
BHBoel Hansson
Boel Hansson
ÅAÅ. Audulv
Å. Audulv
LLL. Lindgren
L. Lindgren
Acoustic noise from magnetic resonance imaging (MRI) can cause hearing loss and needs to be mitigated to ensure the safety of patients and personnel. Capturing MR personnel's insights is crucial for guiding the development and future applications of noise-reduction technology. This study aimed to explore how MR radiographers manage acoustic noise in clinical MR settings. Using a qualitative design, we conducted semi-structured individual interviews with fifteen MR radiographers from fifteen hospitals around Sweden. We focused on the clinical implications of participants' noise management, using an interpretive description approach. We also identified sociotechnical interactions between People, Environment, Tools, and Tasks (PETT) by adopting a Human Factors/Ergonomics framework. Interview data were analyzed inductively with thematic analysis (Braun and Clarke). The analysis generated three main themes regarding MR radiographers' noise management: (I) Navigating Occupational Noise: Risk Management and Adaptation; (II) Protecting the Patient and Serving the Exam, and (III) Establishing a Safe Healthcare Environment with Organizational Support. This study offers insights into radiographers' experiences of managing acoustic noise within MRI, and the associated challenges. Radiographers have adopted multiple strategies to protect patients and themselves from adverse noise-related effects. However, they require tools and support to manage this effectively, suggesting a need for organizations to adopt more proactive, holistic approaches to safety initiatives. The radiographers stressed the importance of a soundproofed work environment to minimize occupational adverse health effects and preserve work performance. They acknowledge noise as a common contributor to patient distress and discomfort. Providing options like earplugs, headphones, mold putty, software-optimized "quiet" sequences, and patient information were important tools. Fostering a safety culture requires proactive safety efforts and support from colleagues and management.

1 May 2022 in Radiography
Verified
Journal Article
Open access
BHBoel Hansson
Boel Hansson
MSM. Simic
M. Simic
JOJ. Olsrud
J. Olsrud
KBK. Markenroth Bloch
K. Markenroth Bloch
TOT. Owman
T. Owman
IBI.M. Björkman-Burtscher
I.M. Björkman-Burtscher
MR facilities must implement and maintain adequate screening and safety procedures to ensure safety during MR examinations. The aim of this study was to evaluate a multi-step MR safety screening process used at a 7T facility regarding incidence of different types of safety risks detected during the safety procedure. Subjects scheduled for an MR examination and having entered the 7T facility during 2016-2019 underwent a pre-defined multi-step MR safety screening process. Screening documentation of 1819 included subjects was reviewed, and risks identified during the different screening steps were compiled. These data were also related to documented decisions made by a 7T MR safety committee and reported MR safety incidents. Passive or active implants (n = 315) were identified in a screening form and/or an additional documented interview in 305 subjects. Additional information not previously self-reported by the subject, regarding implants necessitating safety decisions performed by the staff was revealed in the documented interview in 102 subjects (106 items). In total, the 7T MR safety committee documented a decision in 36 (2%) of the included subjects. All of these subjects were finally cleared for scanning. A multi-step screening process allows a thorough MR screening of subjects, avoiding safety incidents. Different steps in the process allow awareness to rise and items to be detected that were missed in earlier steps. Safety questions posed at a single timepoint during an MR screening process might not reveal all safety risks. Repetition and rephrasing of screening questions leads to increased detection of safety risks. This could be effectively mitigated by a multi-step screening process. A multi-disciplinary safety committee is efficient at short notice responding to unexpected safety issues.