Francisco Pinho

Prof. Dr. Francisco Pinho

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
VFVânia Figueira
Vânia Figueira
SSSandra Silva
Sandra Silva
Inês CostaInês Costa
Inês Costa
BCBruna Alexandra Ribeiro Campos
Bruna Alexandra Ribeiro Campos
JSJoão Pedro Da Costa Alves Salgado
João Pedro Da Costa Alves Salgado
FPFrancisco Pinho
Francisco Pinho
Wearables offer a promising solution for simultaneous posture monitoring and/or corrective feedback. The main objective was to identify, synthesise, and characterise the wearables used in the workplace to monitor and postural feedback to workers. The PRISMA-ScR guidelines were followed. Studies were included between 1 January 2000 and 22 March 2023 in Spanish, French, English, and Portuguese without geographical restriction. The databases selected for the research were PubMed®, Web of Science®, Scopus®, and Google Scholar®. Qualitative studies, theses, reviews, and meta-analyses were excluded. Twelve studies were included, involving a total of 304 workers, mostly health professionals (n = 8). The remaining studies covered workers in the industry (n = 2), in the construction (n = 1), and welders (n = 1). For assessment purposes, most studies used one (n = 5) or two sensors (n = 5) characterised as accelerometers (n = 7), sixaxial (n = 2) or nonaxialinertial measurement units (n = 3). The most common source of feedback was the sensor itself (n = 6) or smartphones (n = 4). Haptic feedback was the most prevalent (n = 6), followed by auditory (n = 5) and visual (n = 3). Most studies employed prototype wearables emphasising kinematic variables of human movement. Healthcare professionals were the primary focus of the study along with haptic feedback that proved to be the most common and effective method for correcting posture during work activities.

28 September 2017 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
FPFrancisco Pinho
Francisco Pinho
JCJoao Jose Cerqueira
Joao Jose Cerqueira
JCJosé Higino Correia
José Higino Correia
NSNuno Sousa
Nuno Sousa
Nuno DiasNuno Dias
Nuno Dias
The World Health Organisation has pointed that a successful health care delivery, requires effective medical devices as tools for prevention, diagnosis, treatment and rehabilitation. Several studies have concluded that longer monitoring periods and outpatient settings might increase diagnosis accuracy and success rate of treatment selection. The long-term monitoring of epileptic patients through electroencephalography (EEG) has been considered a powerful tool to improve the diagnosis, disease classification, and treatment of patients with such condition. This work presents the development of a wireless and wearable EEG acquisition platform suitable for both long-term and short-term monitoring in inpatient and outpatient settings. The developed platform features 32 passive dry electrodes, analogue-to-digital signal conversion with 24-bit resolution and a variable sampling frequency from 250 Hz to 1000 Hz per channel, embedded in a stand-alone module. A computer-on-module embedded system runs a Linux® operating system that rules the interface between two software frameworks, which interact to satisfy the real-time constraints of signal acquisition as well as parallel recording, processing and wireless data transmission. A textile structure was developed to accommodate all components. Platform performance was evaluated in terms of hardware, software and signal quality. The electrodes were characterised through electrochemical impedance spectroscopy and the operating system performance running an epileptic discrimination algorithm was evaluated. Signal quality was thoroughly assessed in two different approaches: playback of EEG reference signals and benchmarking with a clinical-grade EEG system in alpha-wave replacement and steady-state visual evoked potential paradigms. The proposed platform seems to efficiently monitor epileptic patients in both inpatient and outpatient settings and paves the way to new ambulatory clinical regimens as well as non-clinical EEG applications.

6 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Marta Sofia Nicolau Gonçalves de FreitasMarta Sofia Nicolau Gonçalves de Freitas
Marta Sofia Nicolau Gonçalves de Freitas
FPFrancisco Pinho
Francisco Pinho
LPLiliana Pinho
Liliana Pinho
SSSandra Silva
Sandra Silva
VFVânia Figueira
Vânia Figueira
ASAugusta Silva
Augusta Silva
Non-linear and dynamic systems analysis of human movement has recently become increasingly widespread with the intention of better reflecting how complexity affects the adaptability of motor systems, especially after a stroke. The main objective of this scoping review was to summarize the non-linear measures used in the analysis of kinetic, kinematic, and EMG data of human movement after stroke. PRISMA-ScR guidelines were followed, establishing the eligibility criteria, the population, the concept, and the contextual framework. The examined studies were published between 1 January 2013 and 12 April 2023, in English or Portuguese, and were indexed in the databases selected for this research: PubMed®, Web of Science®, Institute of Electrical and Electronics Engineers®, Science Direct® and Google Scholar®. In total, 14 of the 763 articles met the inclusion criteria. The non-linear measures identified included entropy (n = 11), fractal analysis (n = 1), the short-term local divergence exponent (n = 1), the maximum Floquet multiplier (n = 1), and the Lyapunov exponent (n = 1). These studies focused on different motor tasks: reaching to grasp (n = 2), reaching to point (n = 1), arm tracking (n = 2), elbow flexion (n = 5), elbow extension (n = 1), wrist and finger extension upward (lifting) (n = 1), knee extension (n = 1), and walking (n = 4). When studying the complexity of human movement in chronic post-stroke adults, entropy measures, particularly sample entropy, were preferred. Kinematic assessment was mainly performed using motion capture systems, with a focus on joint angles of the upper limbs.

14 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PCPaula Chaves
Paula Chaves
DSDaniela Simões
Daniela Simões
MPMaria Paço
Maria Paço
FPFrancisco Pinho
Francisco Pinho
JDJosé Alberto Duarte
José Alberto Duarte
Fernando RibeiroFernando Ribeiro
Fernando Ribeiro
This study aims to determine if a dose–response relationship exists between the pressure applied during deep friction massage (DFM) and the time to the onset of analgesia in an asymptomatic patellar tendon. For this purpose, pressures applied by physiotherapists during DFM (study 1) were characterized and then, based on these pressures, the effects of different DFM pressures on the time to the onset of analgesia were assessed (study 2). First, the mean pressure applied by 40 physiotherapists during a DFM session was assessed with a pressure sensor through an observational, cross-sectional and analytical study. Next, the effects of different pressure intensities (the median, the percentile 25 (P25), and the percentile 75 (P75) of the mean pressure obtained in study 1) were studied in a crossover trial enrolling 30 participants with an asymptomatic patellar tendon. A pressure sensor was used to register the pressures applied during DFM. Our main results indicated that the physiotherapists applied pressures with a wide variation ((mean pressure: 2.317 kg/cm2 (P25: 1.022 kg/cm2; P75: 4.161 kg/cm2)). It was also shown that higher pressures had shorter times to the onset of analgesia (pressure: 1 kg/m2, time to the onset of analgesia: 67.0 s (P25: 84.5 s; P75: 113.5 s); pressure: 2.3 kg/m2, time to the onset of analgesia: 59.0 s (P25: 73.5 s; P75: 87.3 s); pressure: 4.2 kg/m2, time to the onset of analgesia: 37.8 s (P25: 54.0 s; P75: 62.0 s)) (p ≤ 0.001). In conclusion, the mean DFM pressure obtained by the physiotherapists was 2.3 kg/cm2 (P25: 1.02 kg/cm2; P75: 4.16 kg/cm2). Higher pressures of DFM resulted in shorter times to the onset of analgesia.

15 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
SPSílvia Pires
Sílvia Pires
Marta Sofia Nicolau Gonçalves de FreitasMarta Sofia Nicolau Gonçalves de Freitas
Marta Sofia Nicolau Gonçalves de Freitas
FPFrancisco Pinho
Francisco Pinho
FBFernanda Soofia Brandão
Fernanda Soofia Brandão
Objective: We aimed to quantify the mechanical pressure required to reach the deep cervical and thoracolumbar fasciae, to examine its association with pressure pain threshold (PPT) and adipose tissue thickness, and to determine whether PPT and adipose tissue thickness can predict the mechanical pressure needed to reach the fascia. Methods: Forty-three subjects’ PPT, mechanical pressure and skinfold in the trapezius and lumbar regions were evaluated using an algometer, an ultrasound scanner, and an adipometer. The Wilcoxon test, Student’s t-test, and Pearson and Spearman’s correlation tests were used (p < 0.05). Results: The values of mechanical pressure in the cervical and lumbar regions were 6.06 ± 0.186 N/cm2 and 5.85 ± 5.280, 7.287 N/cm2, respectively. PPT values were 18.88 ± 0.917 N/cm2, and 46.46 ± 2.408 N/cm2, respectively (p < 0.001), and the adipose tissue thickness values in the cervical and lumbar regions were 0.88 ± 0.675 cm, 1.08 and 1.48 ± 0.069 cm (p < 0.001). There was no correlation between the variables in either region under study. Conclusions: The mechanical pressure required to reach the deep cervical and thoracolumbar fasciae was similar with an average value of approximately 6 N/cm2, suggesting a consistent mechanical response across these anatomical regions. Mechanosensitivity and subcutaneous adipose tissue thickness did not influence the mechanical pressure needed to access the deep fascial tissue.

11 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LPLiliana Pinho
Liliana Pinho
SSSandra Silva
Sandra Silva
Marta Sofia Nicolau Gonçalves de FreitasMarta Sofia Nicolau Gonçalves de Freitas
Marta Sofia Nicolau Gonçalves de Freitas
VFVânia Figueira
Vânia Figueira
FPFrancisco Pinho
Francisco Pinho
ASAugusta Silva
Augusta Silva
Assessment of muscle tone in a clinical setting is important for the physiotherapist to better analyse and establish appropriate treatments for CNS disorders. This study aims to review and summarise how to assess changes in tone in the context of adult rehabilitation. Secondarily, this study aimed to identify the central nervous system disorders, the respective variable/concept under study, and the testing procedures employed. PRISMA-ScR guidelines were followed using the “population”, “concept”, and “context” to define the eligibility criteria and to delineate the research question. PubMed®, Science Direct®, Web of Science™, and Google Scholar® databases were used to search the literature. The search included studies published between 2011 and March 2023 in Portuguese, English, French, and Spanish that assessed an adult population (>19 years) with CNS injury. Review articles, qualitative studies, conference proceedings, letters to the editor, and editorials were excluded. Initially, 1519 references were identified, of which eight met the eligibility criteria. The measurement instruments included the Modified Ashworth Scale (n = 5), the Modified Modified Ashworth Scale (n = 3), the BioTone™ system (n = 2), the Montreal Spasticity Measurement (n = 1), and the Tone Evaluation Scale (n = 1). The health conditions considered included stroke sequelae (n = 7), multiple sclerosis (n = 4), spinal cord injuries (n = 4), cerebral palsy (n = 2), brain tumour (n = 2), and traumatic brain injuries (n = 3). The concepts of spasticity (n = 7) and muscle tone (n = 2) were explored. Considering the variables spasticity and muscle tone in different CNS disorders, mainly stroke, subjective instruments were preferred compared to objective ones, with the Modified Ashworth Scale being highlighted.