Elizaveta Pavlova

Mrs. Elizaveta Pavlova


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
EPElizaveta Pavlova
Elizaveta Pavlova
INI E Nifant’eV
I E Nifant’eV
MMM E Minyaev
M E Minyaev
DBD V Bagrov
D V Bagrov
DKD V Klinov
D V Klinov
Electrospinning of biodegradable poly(ω-pentadecalactone) (PPDL) is poorly investigated. In the present work, PPDL homopolymers of different molecular weight were synthesized by ring-opening polymerization of ωPDL, and then electrospun. Mixtures of PPDL with hexafluoro-2-propanol (HFIP) and with HFIP-chloroform blend were used for electrospinning. Since PPDL is poorly soluble in HFIP at high concentrations, the PPDL-HFIP mixture was turbid and its electrospinning led to heterogeneous mats. Addition of 30% of chloroform to the PPDL-HFIP mixture turned it into a transparent solution. After electrospinning, the PPDL-HFIP-chloroform mixtures yielded mats, which consisted of flat and round fibers with a wrinkled surface. The flat fibers (ribbons) were observed more frequently when the PPDL sample with the highest molecular weight was electrospun. All the obtained electrospun mats demonstrated high elongation at break (from 150% to 350%). In our future research, these mats will be examined as biomaterials.

26 May 2023 in Micro
Verified
Journal Article
Open access
PDF file
AMAitsana Maslakova
Aitsana Maslakova
KPKirill Prusakov
Kirill Prusakov
ASAnastasia Sidorova
Anastasia Sidorova
EPElizaveta Pavlova
Elizaveta Pavlova
ARAlla Ramonova
Alla Ramonova
DBDmitry Bagrov
Dmitry Bagrov
Electrospun polymer membranes are regarded as prospective biosensor components due to their large specific surface area and diverse opportunities for chemical modifications. However, their intricate porous structure can impede diffusion and render some analyte-binding sites inaccessible. To overcome these diffusion limitations and improve analyte adsorption onto the polymer, a pressure-driven sample flow through the membrane can be employed. To date, the efficiency of pressure-driven analyte delivery into these membranes has not been quantified. Here, we compare forced flow and passive sample diffusion through poly(dioxanone) electrospun membranes. We examine two model analytes, BSA and interleukin-1 beta (IL1b), to address both non-specific and specific binding. Following exposure of the membranes to the test solutions, we measured the residual concentrations of the analytes using fluorometry and enzyme-linked immunosorbent assay (ELISA) techniques. The pressure-driven sample loading was superior to passive diffusion, with a 2.8–11.5-fold change for physical adsorption and a 2.4–3.4-fold difference for specific binding. Our data can be useful for the development of immunoassays and microfluidic devices.