We measure the thermoelectric response of Corbino structures in the quantum Hall effect regime and compare it with a theoretical analysis. The measured thermoelectric voltages are qualitatively and quantitatively simulated based upon the independent measurement of the conductivity, indicating that they originate predominantly from the electron diffusion. In contrast to earlier Hall-bar experiments, electron-phonon interaction does not lead to a phonon-drag contribution. This implies a description of the Onsager coefficients on the basis of a single transmission function, from which both thermovoltage and conductivity can be predicted with a single fitting parameter. Furthermore, it lets us predict a figure of merit for the efficiency of thermoelectric cooling, which becomes very large for partially filled Landau levels and high magnetic fields.
We analyze the thermoelectric cooling properties of a Corbino device in the quantum Hall regime on the basis of experimental data of electrical conductance. We focus on the cooling power and the coefficient of performance within and beyond linear response. Thermovoltage measurements in this device reported by Real et al., [ Phys. Rev. Appl. 14, 034019 (2020)] indicated that the transport takes place in the diffusive regime, without signatures of effects due to the electron-phonon interaction in a wide range of temperatures and filling factors. In this regime, the heat and charge currents by electrons can be described by a single transmission function. We infer this function from experimental data of conductance measurements and we calculate the cooling power and the coefficient of performance for a wide range of filling factors and temperatures, as functions of the thermal and electrical biases. We predict an interesting cooling performance in several parameter regimes.
29 October 2025 in Measurement Science and Technology
The AC quantum voltmeter (QVM) has been extended with a sampling method that removes the gaps unavoidably linked to the transitions in the Programmable Josephson Voltage Standard. The method has been validated to the level of 2.4 parts in 10 8 at 1 kHz and an RMS amplitude of 1 V. The AC QVM using seamless sampling can then measure multitone signals, and we reached a relative agreement of 10 −7 VV −1 ( k = 1) for a multitone signal from a Josephson arbitrary waveform synthesizer with an amplitude at the level of 100 mV. The noise level in the frequency spectrum of the reconstructed signal was below −120 dBc highlighting the potential of the seamless sampling method. Successful calibrations of conventional generators are also demonstrated.
We present an experimental technique to generate and measure a temperature bias in the quantum Hall effect of GaAs/AlGaAs Corbino samples. The bias is generated by injecting an electric current at a central resistive heater, and the resulting radial temperature drop is determined by conductance measurements at internal and external concentric rings. The experimental results agree with the predictions of numerical simulations of the heat flow through the substrate. We also compare these results with previous predictions based on the thermoelectric response of these devices.
We present an experimental technique to generate and measure a temperature bias in the quantum Hall effect of GaAs/AlGaAs Corbino samples. The bias is generated by injecting an electrical current at a central resistive heater and the resulting radial temperature drop is determined by conductance measurements at internal and external concentric rings. The experimental results agree with the predictions of numerical simulations of the heat flow through the substrate. We also compare these results with previous predictions based on the thermoelectric response of these devices
25 February 2026 in IEEE Transactions on Applied Superconductivity
Microwave SQUID multiplexers (μMUX) have become a key technology for the readout of large arrays of low-temperature detectors, particularly in cosmic microwave background experiments. A critical element of this technique is the flux-ramp modulation signal, whose noise, especially at low frequencies, directly limits the readout performance. This work proposes and experimentally demonstrates the use of a Josephson Arbitrary Waveform Synthesizer (JAWS) as a low-noise, high precision source for generating the sawtooth-shaped flux-ramp signal required in μMUX readout systems. The JAWS, based on the AC Josephson effect, provides intrinsically quantized and spectrally pure waveforms with excellent signal-to-noise ratio. The operation of a 9000-junction JAWS array is characterized and integrated with a cryogenic μMUX device and a custom SDR-based readout system. With this setup, the noise floor level around the harmonic typically used for phase demodulation of the SQUID signal to recover the detector signal was −104dBc/Hz, and the signal-to-noise ratio of this harmonic was 73dB. These results demonstrate the feasibility of using JAWS-based waveform synthesis for μMUX flux-ramp generation.