A novel 4-to-2 photonic crystal encoder is proposed by modulating the intensity of four input optical signals, and four distinct output states are achieved. Nonlinear rods are employed to couple input waves into resonant cavities, directing the light to the desired output waveguides. The proposed design, with a footprint of 114 µm2, demonstrates efficient encoding operation at a wavelength of 1550 nm and is highly suitable for integrated photonics applications. A comprehensive comparative analysis revealed that the proposed 4-to-2 encoder exhibits a time response 176 fs faster than previously presented encoders. Furthermore, the contrast ratio of the designed structure is as high as 13.78 dB to distinguish between logic 0 and 1. These advancements hold significant potential for enhancing the performance of compact, high-speed digital circuits.
We propose a novel twelve-channel Dense Wavelength Division Multiplexing (DWDM) demultiplexer, using the two-dimensional photonic crystal (2D PC) with square resonant cavity (SRC) of ITU-T G.694.1 standard. The DWDM demultiplexer consists of an input waveguide, SRC, and output waveguide. The SRC in the proposed demultiplexer consists of square resonator and microcavity. The microcavity center rod radius () is proportional to refractive index. The refractive index property of the rods filters the wavelengths of odd and even channels. The proposed microcavity can filter twelve ITU-T G.694.1 standard wavelengths with 0.2 nm/25 GHz channel spacing between the wavelengths. From the simulation, we optimize the rod radius and wavelength with linear regression analysis. From the regression analysis, we can achieve 95% of accuracy with an average quality factor of 7890, the uniform spectral line-width of 0.2 nm, the transmission efficiency of 90%, crosstalk of −42 dB, and footprint of about 784 μm2.
A two-dimensional photonic crystal biosensor is theoretically demonstrated and investigated based on refractive index sensing. It detects the chikungunya virus (CHIKV) in the various blood components with high sensitivity of 421.5 nm/RIU. Simulation and various analyses are done with both normal and infected blood constituents (uric acid, platelets and plasma) to detect CHIKV. The sensor operates within the wavelength range of 1230–1560 nm. The important optical parameters such as sensitivity and quality factor are analyzed and numerical investigations are done with the finite difference time domain method. The sensor is built with a circular array of holes etched on a silicon slab in a hexagonal lattice pattern. A nanohole resonant sensing cavity is placed at the center of two waveguides, enhancing the light–matter interaction of the analyte and trapping the optical mode at the nanohole of the sensor. When the sensor is completely submerged in blood constituents infected with CHIKV (plasma, platelets and uric acid), the resonating modes undergo a shift as the refractive index of each analyte is unique. The sensor has a very high sensitivity of 421.5 nm RIU−1, and a good quality factor of 229.68 for the different blood constituents is obtained. A maximum transmission of 89.25% with a detection limit of 0.01 are obtained and reported in this work.