The high frequency and complexity of mandibular third molar (M3M) surgery have led several authors to the development of classification systems for better evaluation and management in oral surgery. This study compared the classifications of Juodzabalys and Daugela et al. (JD), Sammartino et al., Chang et al., Jhamb et al., Maglione et al., and Nemsi et al. to understand the concordance between the scores of M3M surgery. Two types of analysis were conducted: the relationship between the M3M and the inferior alveolar nerve (IAN), and the overall difficulty score based on the tooth’s angulation and its spatial position with the adjacent structure. The analysis of the classifications on the relationship between M3M and IAN resulted in a concordance of 26.1%. In the pairwise comparisons, the classifications of Nemsi et al. and Jhamb et al. showed the highest concordance of 59.5%. Analyzing the total scores difficulty, the JD et al., Chang et al., and Sammartino et al. classifications demonstrated a concordance level of 25.5%. A pairwise assessment revealed a higher concordance degree between the classifications of Sammartino et al. and Chang et al. (57.4%). The results highlight the limits in establishing a comprehensive and objective classification for the surgical difficulty of M3M, possibly attributed to variations in the methodology for computing total scores. An objective, automated, and non-operator-dependent classification method for assessing the surgical difficulty of M3M is still needed.
Background/Objectives: Autofluorescence (AF) is a widely used adjunctive tool in the detection of oral potentially malignant disorders (OPMDs) and malignant lesions, but its performance can be influenced by clinicians’ experiences. This study aimed to examine how AF influences diagnostic decision-making and performances of a novice clinician compared with those of an experienced examiner. Methods: A total of 80 patients with oral lesions participated in this cross-sectional study. Each underwent a standard oral examination (OE) followed by an assessment with the VELscope® System Vx (LED Medical Diagnostics Inc., Burnaby, BC, Canada), independently conducted by an expert clinician (E) and a postgraduate dentist (PD), both blinded to each other’s results. Biopsy and histopathological analysis provided the reference diagnosis. After every examination, lesions were categorized as either “Risk of Malignancy” (RM) or “No Risk of Malignancy” (NRM). Results: Based on OE, PD identified 39 RM lesions, while E 29. AF with VELscope® identified an additional 12 RM lesions for the PD and 7 for the E that were not suspected on OE alone. Combining OE with VELscope® improved sensitivity (PD: 90.9%; E: 95.4%) and negative predictive value (PD: 91.7%; E: 97.6%), while decreasing specificity (PD: 37.9%; E: 70.7%) and positive predictive value (PD: 35.7%; E: 55.3%) compared with OE alone. Conclusions: AF increases diagnostic sensitivity, particularly for less experienced clinicians, while offering moderate advantages for experts. Nevertheless, the corresponding decline in specificity emphasizes the need for cautious interpretation. AF should be incorporated as a complementary tool within structured diagnostic pathways, accompanied by adequate training, and cannot replace histopathological confirmation or clinical expertise.
Background: Rehabilitation of atrophic posterior jaws is often challenging due to anatomical limitations, frequently requiring bone augmentation procedures or the use of short implants. Expandable short implants are characterized by an expansion mechanism whose potential contribution to primary stability remains to be fully established. This ex vivo study compared the primary stability of expandable and conventional short implants in porcine rib bone of low and intermediate CBCT-defined density (corresponding approximately to Misch D4 and D3). Methods: A total of 68 implants were placed in 17 fresh porcine ribs, using a randomized complete block design: 34 expandable short implants (ESI; Pyramidion, Ø4.1 × 5 mm) and 34 conventional short implants (CSI; Osstem TS III, Ø4 × 7 mm), equally distributed between two CBCT-defined density strata (D3 and D4, operationally defined). Peak insertion torque (PIT), resonance frequency analysis (ISQ; before and after apical expansion for the ESI group), peak removal torque (PRT), and expansion torque (ESI group only) were recorded. Data were analyzed using a two-way ANOVA (implant group × bone density) with a Bonferroni-corrected significance threshold (α = 0.025) for the two primary outcomes, ISQ and PRT. Results: PIT did not differ significantly between groups in D3 bone, while CSI showed higher PIT in D4 bone (p = 0.0005). ISQ increased significantly following apical expansion in the ESI group (mean + 4.91, 95% CI 3.60 to 6.22; p = 0.0004), more markedly in D4 than D3 bone; final ISQ did not differ significantly between groups at either bone density. PRT was higher in the ESI group in both density strata (p = 0.0004 in D3 and p = 0.0003 in D4), with no significant implant group × bone density interaction. Incomplete apical expansion occurred in 3 of 34 ESI implants, all in D3 bone. Conclusions: In this ex vivo model, no statistically significant difference in final ISQ was detected between the expandable and conventional short implants, and removal torque was higher for the expandable implant across both bone densities; equivalence was not tested. These findings refer to the initial mechanical behaviour under the tested ex vivo conditions, without implying superiority over conventional implant designs; further studies are warranted.