Hyeon-gyo Chae

Ms. Hyeon-gyo Chae

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2024 in Machines
Verified
Journal Article
Open access
PDF file
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
Interest in electric propulsion ships has garnered attention to reduce ship exhaust emissions. This has sparked extensive research on inverters. While two-level voltage source inverters are commonly utilized in small- and medium-sized ships owing to their simple structure and cost-effectiveness, they have limitations, such as high switching losses and reduced output performance. To address these issues, a model predictive control technique based on virtual voltage vectors is proposed in this study. Conventional two-level voltage source inverters are restricted to using only eight voltage vectors, which limits their output performance. By incorporating virtual voltage vectors, similar performance to multilevel converters can be achieved. The proposed technique involves a pre-voltage selection method that enhances output performance without increasing computational load. Through simulation and experiments, improved output current THD and current error were observed under various load conditions. This showcases the potential for enhancing the efficiency and performance of electric propulsion ships.

Verified
Journal Article
Open access
PDF file
SJSEOHEE JANG
SEOHEE JANG
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
Wind-assisted propulsion using Flettner rotors has gained attention as the shipping sector faces stricter decarbonization regulations. This study compares conventional Fixed Speed Control with Adaptive Speed Control for a 100 m coastal vessel. The proposed Adaptive Speed Control selectively activates the rotor based on relative wind conditions and adjusts rotor speed according to the surge-direction projection of Magnus force. A simulation framework based on the MMG maneuvering model evaluates path-following performance, fuel consumption, and annual performance indicators. Results show that Adaptive Speed Control achieves 18.84% reduction in fuel consumption, corresponding to annual savings of 212.02 tons of fuel, USD 190,823 in OPEX, and 679.76 tons of CO2 emissions. Selective rotor operation reduces the Fatigue Damage Index by approximately 89%, resulting in 84.48% reduction in annual maintenance costs. Unwanted lateral forces and yaw disturbances are mitigated, improving path-following and maneuvering stability. These findings demonstrate that situationally aware Adaptive Speed Control improves energy efficiency and operational characteristics of Flettner-rotor-assisted propulsion systems while maintaining maneuvering performance, providing practical guidance for wind-assisted ship operation under realistic coastal conditions.

15 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Euicheol ShinEuicheol Shin
Euicheol Shin
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
Electric propulsion ships have garnered significant attention for addressing the environmental impact associated with conventional shipping vessels. Their performance critically depends on the inverters that control propulsion motors. This study aims to enhance inverter control by addressing the limitations of conventional model predictive control (MPC), particularly its high current errors and total harmonic distortion (THD) owing to the limited switching frequency. Herein, a discontinuous MPC is proposed that is capable of reducing the switching losses by implementing discontinuous switching during high current periods. This approach employs zero-voltage vectors that are selected based on the polarity of the offset voltage to prevent unnecessary switching losses. Experimental results indicate that the proposed approach reduces the current error by up to 45%, THD by up to 30%, and switching losses by 15–25%. Therefore, this study demonstrates the potential of the proposed control strategy to improve the efficiency and reliability of electric propulsion systems, thereby contributing to the advancement of inverter control technology and development of eco-friendly shipping vessels.

Verified
Journal Article
Open access
PDF file
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
Wave energy converters (WECs) have significant potential to meet the increasing energy demands and using an oscillating water column (OWC) is one of the most reliable ways to implement them. The OWC has a simple structure and excellent durability. However, control of the power take-off (PTO) system is difficult due to variability in the input wave energy. In particular, the design and control of the PTO system are complex, as the average-to-peak ratio of the output generation is large. Owing to the nature of the OWC, if the energy above the rating cannot be controlled, the power generated is inevitably reduced due to the decrease in operating time. We propose a method to reduce the angular speed of the turbine by dividing the section according to the input energy and correspondingly changing the torque coefficient, thereby increasing the operating time of the OWC. The control methods for the PTO system of OWC are verified through a 30 kW full-scale experimental device to be installed in a real sea area. The full-scale experimental device consists of an inverter that simulates the mechanical torque of an OWC based on the aerodynamic simulation of an impulse turbine, an induction motor, a permanent magnet synchronous generator, an AC/DC converter, and a battery for the energy storage system. The performance of conventional control methods and the proposed method are compared based on the results of numerical simulations and experiments. We show that the fluctuation in the turbine angular velocity in the proposed method is significantly reduced compared with that in the conventional control methods under regular and irregular wave conditions.

Verified
Journal Article
Open access
PDF file
SJSEOHEE JANG
SEOHEE JANG
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
This paper presents a controller-hardware-in-the-loop simulation (C-HILS) framework for validating models, evaluating control performance, and assessing the thermal lifetime of a tens-of-kilowatt inverter. The real inverter and the C-HILS platform were operated in parallel, and accuracy was quantified using phase-current root mean square error, voltage spectral analysis, and total harmonic distortion (THD). Across a wide range of SVPWM and DPWM cases, deviations remained within 2–5%, confirming close agreement between experiment and simulation. Using the validated C-HILS system, sampling frequency and output power were swept while comparing current tracking, THD, average switching frequency, semiconductor losses, and efficiency. SVPWM achieved lower THD, whereas DPWM reduced average switching frequency and switching losses, improving efficiency. C-HILS waveforms were then applied to a Foster thermal network to reconstruct the junction–temperature trajectory; Tj(t), and ΔTj and Tj,min were mapped to lifetime using the Bayerer model. For a representative cyclic mission, ΔTj decreased from approximately 25.6 °C with SVPWM to about 17.5 °C with DPWM, increasing the estimated lifetime from approximately 1.36 years to 9.14 years. These results demonstrate that the proposed C-HILS framework provides a unified pre-prototype tool for model verification, control strategy comparison, and quantitative thermal reliability assessment of shipboard propulsion inverters.

Verified
Journal Article
Open access
PDF file
HCHyeon-gyo Chae
Hyeon-gyo Chae
chan rohchan roh
chan roh
The accelerated global transition toward eco-friendly mobility has necessitated robust decarbonization measures across the maritime sector, with battery-powered electric propulsion ships emerging as a promising alternative. Accordingly, the applicability of silicon carbide (SiC)-based technology to propulsion inverters, a key component of such vessels, is currently under investigation. Although life cycle assessment (LCA) studies comparing conventional silicon (Si)-based and SiC-based inverters have been conducted previously, these analyses neglect realistic operating profiles and load fluctuations, limiting their applicability. Furthermore, life cycle cost assessment (LCCA) integrating real-world operating conditions has rarely been addressed. To address these gaps, this study conducted a comparative LCA and LCCA of Si IGBT and SiC MOSFET inverters for marine electric propulsion systems across three vessel types: a cruise ship, a passenger and car ship, and a recreational boat, incorporating real-world load profiles to evaluate global warming potential (GWP), fossil depletion (FD), and cumulative energy demand (CED). The static LCA results showed negligible differences between inverter types, contributing less than 1% to total impacts. The dynamic LCA demonstrated that SiC MOSFET inverters reduced environmental impacts by approximately 57%, 52%, and 34% for cruise ships, passenger and car ships, and recreational boats, respectively. Despite a 40% higher initial investment cost, SiC inverters achieved payback periods well within vessel lifetimes across all vessel types. These findings support SiC inverters as a sustainable and economically viable solution for ship electrification.