Philipp Hoegen-Saßmannshausen

Dr. Philipp Hoegen-Saßmannshausen


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2024 in Cancers
Verified
Journal Article
Open access
PDF file
MVMaria Vinsensia
Maria Vinsensia
RSRiccarda Schaub
Riccarda Schaub
EMEva Meixner
Eva Meixner
PHPhilipp Hoegen-Saßmannshausen
Philipp Hoegen-Saßmannshausen
NANathalie Arians
Nathalie Arians
JHJuliane Hörner-Rieber
Juliane Hörner-Rieber
Our study aims to identify the risk factors and dosimetry characteristics associated with capsular contracture. Methods: We retrospectively analyzed 118 women with breast cancer who underwent PMRT following an IBR between 2010 and 2022. Patients were treated with PMRT of 50.0–50.4 Gy in 25–28 fractions. Capsular contracture was categorized according to the Baker Classification for Reconstructed Breasts. Results: After a median follow-up of 22 months, the incidence of clinically relevant capsular contracture (Baker III–IV) was 22.9%. Overall, capsular contracture (Baker I–IV) occurred in 56 patients (47.5%) after a median of 9 months after PMRT. The rate of reconstruction failure/implant loss was 25.4%. In the univariate analysis, postoperative complications (prolonged pain, prolonged wound healing, seroma and swelling) and regional nodal involvement were associated with higher rates of capsular contracture (p = 0.017, OR: 2.5, 95% CI: 1.2–5.3 and p = 0.031, respectively). None of the analyzed dosimetric factors or the implant position were associated with a higher risk for capsular contracture. Conclusion: Postoperative complications and regional nodal involvement were associated with an increased risk of capsular contracture following breast reconstruction and PMRT, while none of the analyzed dosimetric factors were linked to a higher incidence. Additional studies are needed to identify further potential risk factors.

27 March 2022 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
PHPhilipp Hoegen-Saßmannshausen
Philipp Hoegen-Saßmannshausen
KZK. S. Zhang
K. S. Zhang
ETE. Tonndorf-Martini
E. Tonndorf-Martini
Fabian WeykampFabian Weykamp
Fabian Weykamp
SRSebastian Regnery
Sebastian Regnery
JHJuliane Hörner-Rieber
Juliane Hörner-Rieber
Background: Stereotactic body radiotherapy (SBRT) is an established local treatment method for patients with hepatic oligometastasis or oligoprogression. Liver metastases often occur in close proximity to radiosensitive organs at risk (OARs). This limits the possibility to apply sufficiently high doses needed for optimal local control. Online MR-guided radiotherapy (oMRgRT) is expected to hold potential to improve hepatic SBRT by offering superior soft-tissue contrast for enhanced target identification as well as the benefit of gating and daily real-time adaptive treatment. The MAESTRO trial therefore aims to assess the potential advantages of adaptive, gated MR-guided SBRT compared to conventional SBRT at a standard linac using an ITV (internal target volume) approach. Methods: This trial is conducted as a prospective, randomized, three-armed phase II study in 82 patients with hepatic metastases (solid malignant tumor, 1–3 hepatic metastases confirmed by magnetic resonance imaging (MRI), maximum diameter of each metastasis ≤ 5 cm (in case of 3 metastases: sum of diameters ≤ 12 cm), age ≥ 18 years, Karnofsky Performance Score ≥ 60%). If a biologically effective dose (BED) ≥ 100 Gy (α/β = 10 Gy) is feasible based on ITV-based planning, patients will be randomized to either MRgRT or ITV-based SBRT. If a lesion cannot be treated with a BED ≥ 100 Gy, the patient will be treated with MRgRT at the highest possible dose. Primary endpoint is the non-inferiority of MRgRT at the MRIdian Linac® system compared to ITV-based SBRT regarding hepatobiliary and gastrointestinal toxicity CTCAE III or higher. Secondary outcomes investigated are local, locoregional (intrahepatic) and distant tumor control, progression-free survival, overall survival, possible increase of BED using MRgRT if the BED is limited with ITV-based SBRT, treatment-related toxicity, quality of life, dosimetric parameters of radiotherapy plans as well as morphological and functional changes in MRI. Potential prognostic biomarkers will also be evaluated. Discussion: MRgRT is known to be both highly cost- and labor-intensive. The MAESTRO trial aims to provide randomized, higher-level evidence for the dosimetric and possible consecutive clinical benefit of MR-guided, on-table adaptive and gated SBRT for dose escalation in critically located hepatic metastases adjacent to radiosensitive OARs. Trial registration: The study has been prospectively registered on August 30th, 2021: Clinicaltrials.gov, “Magnetic Resonance-guided Adaptive Stereotactic Body Radiotherapy for Hepatic Metastases (MAESTRO)”, NCT05027711.

1 March 2019 in Cancers
Verified
Journal Article
Open access
PDF file
RSRami Ateyah El Shafie
Rami Ateyah El Shafie
ETEric Tonndorf-Martini
Eric Tonndorf-Martini
DSDaniela Schmitt
Daniela Schmitt
DWDorothea Weber
Dorothea Weber
ACAylin Celik
Aylin Celik
SRStefan Rieken
Stefan Rieken
Background: Pre-operative radiosurgery (SRS) preceding the resection of brain metastases promises to circumvent limitations of post-operative cavity SRS. It minimizes uncertainties regarding delineation and safety margins and could reduce dose exposure of the healthy brain (HB). Methods: We performed a systematic treatment plan comparison on 24 patients who received post-operative radiosurgery of the resection cavity at our institution. Comparative treatment plans were calculated for hypofractionated stereotactic radiotherapy (7 × 5 Gray (Gy)) in a hypothetical pre-operative (pre-op) and two post-operative scenarios, either with (extended field, post-op-E) or without the surgical tract (involved field, post-op-I). Detailed volumetric comparison of the resulting target volumes was performed, as well as dosimetric comparison focusing on targets and the HB. Results: The resection cavity was significantly smaller and different in morphology from the pre-operative lesion, yielding a low Dice Similarity Coefficient (DSC) of 53% (p = 0.019). Post-op-I and post-op-E targets showed high similarity (DSC = 93%), and including the surgical tract moderately enlarged resulting median target size (18.58 ccm vs. 22.89 ccm, p < 0.001). Dosimetric analysis favored the pre-operative treatment setting since it significantly decreased relevant dose exposure of the HB (Median volume receiving 28 Gy: 6.79 vs. 10.79 for pre-op vs. post-op-E, p < 0.001). Dosimetrically, pre-operative SRS is a promising alternative to post-operative cavity irradiation that could furthermore offer practical benefits regarding delineation and treatment planning. Comparative trials are required to evaluate potential clinical advantages of this approach.

8 December 2022 in Cancers
Verified
Journal Article
Open access
PDF file
Fabian WeykampFabian Weykamp
Fabian Weykamp
EKEfthimios Katsigiannopulos
Efthimios Katsigiannopulos
LPLars Piskorski
Lars Piskorski
SRSebastian Regnery
Sebastian Regnery
PHPhilipp Hoegen-Saßmannshausen
Philipp Hoegen-Saßmannshausen
JHJuliane Hörner-Rieber
Juliane Hörner-Rieber
(1) Background: To assess dosimetry benefits of stereotactic magnetic resonance (MR)-guided online adaptive radiotherapy (SMART) of liver metastases. (2) Methods: This is a subgroup analysis of an ongoing prospective registry including patients with liver metastases. Patients were treated at the MRIdian Linac between February 2020 and April 2022. The baseline plan was recalculated based on the updated anatomy of the day to generate the predicted plan. This predicted plan could then be re-optimized to create an adapted plan. (3) Results: Twenty-three patients received 30 SMART treatment series of in total 36 liver metastases. Most common primary tumors were colorectal- and pancreatic carcinoma (26.1% respectively). Most frequent fractionation scheme (46.6%) was 50 Gy in five fractions. The adapted plan was significantly superior compared to the predicted plan in regard to planning-target-volume (PTV) coverage, PTV overdosing, and organs-at-risk (OAR) dose constraints violations (91.5 vs. 38.0%, 6 vs. 19% and 0.6 vs. 10.0%; each p < 0.001). Plan adaptation significantly increased median BEDD95 by 3.2 Gy (p < 0.001). Mean total duration of SMART was 72.4 min. (4) Conclusions: SMART offers individualized ablative irradiation of liver metastases tailored to the daily anatomy with significant superior tumor coverage and improved sparing of OAR.

17 May 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Fabian WeykampFabian Weykamp
Fabian Weykamp
PHPhilipp Hoegen-Saßmannshausen
Philipp Hoegen-Saßmannshausen
SRSebastian Regnery
Sebastian Regnery
EKEfthimios Katsigiannopulos
Efthimios Katsigiannopulos
CRC. Katharina Renkamp
C. Katharina Renkamp
JHJuliane Hörner-Rieber
Juliane Hörner-Rieber
(1) Background: Magnetic-resonance (MR)-guided stereotactic body radiotherapy (SBRT) allows for ablative, non-invasive treatment of liver metastases. However, long-term clinical outcome data are missing. (2) Methods: Patients received MR-guided SBRT with a MRIdian Linac between January 2019 and October 2021 and were part of an ongoing prospective observational registry. Local hepatic control (LHC), distant hepatic control (DHC), progression free survival (PFS) and overall survival (OS) were estimated with the Kaplan–Meier method. Toxicity was documented according to CTCAE (v.5.0). (3) Results: Forty patients were treated for a total of 54 liver metastases (56% with online plan adaptation). Median prescribed dose was 50 Gy in five fractions equal to a biologically effective dose (BED) (alpha/beta = 10 Gy) of 100 Gy. At 1 and 2 years, LHC was 98% and 75%, DHC was 34% and 15%, PFS was 21% and 5% and OS was 83% and 57%. Two-year LHC was higher in case of BED > 100 Gy (100% vs. 57%; log-rank p = 0.04). Acute grade 1 and 2 toxicity (mostly nausea) occurred in 26% and 7% of the patients, with no grade ≥ 3 event. (4) Conclusions: To our knowledge, this is the largest cohort of MR-guided liver SBRT. Long-term local control was promising and underscores the aim of achieving >100 Gy BED. Nonetheless, distant tumor control remains challenging.

18 January 2024 in Cancers
Verified
Journal Article
Open access
PDF file
AWAlexandra Walter
Alexandra Walter
PHPhilipp Hoegen-Saßmannshausen
Philipp Hoegen-Saßmannshausen
GSGoran Stanic
Goran Stanic
JRJoao Pedro Rodrigues
Joao Pedro Rodrigues
SASebastian Adeberg
Sebastian Adeberg
KGKristina Giske
Kristina Giske
The delineation of the clinical target volumes (CTVs) for radiation therapy is time-consuming, requires intensive training and shows high inter-observer variability. Supervised deep-learning methods depend heavily on consistent training data; thus, State-of-the-Art research focuses on making CTV labels more homogeneous and strictly bounding them to current standards. International consensus expert guidelines standardize CTV delineation by conditioning the extension of the clinical target volume on the surrounding anatomical structures. Training strategies that directly follow the construction rules given in the expert guidelines or the possibility of quantifying the conformance of manually drawn contours to the guidelines are still missing. Seventy-one anatomical structures that are relevant to CTV delineation in head- and neck-cancer patients, according to the expert guidelines, were segmented on 104 computed tomography scans, to assess the possibility of automating their segmentation by State-of-the-Art deep learning methods. All 71 anatomical structures were subdivided into three subsets of non-overlapping structures, and a 3D nnU-Net model with five-fold cross-validation was trained for each subset, to automatically segment the structures on planning computed tomography scans. We report the DICE, Hausdorff distance and surface DICE for 71 + 5 anatomical structures, for most of which no previous segmentation accuracies have been reported. For those structures for which prediction values have been reported, our segmentation accuracy matched or exceeded the reported values. The predictions from our models were always better than those predicted by the TotalSegmentator. The sDICE with 2 mm margin was larger than 80% for almost all the structures. Individual structures with decreased segmentation accuracy are analyzed and discussed with respect to their impact on the CTV delineation following the expert guidelines. No deviation is expected to affect the rule-based automation of the CTV delineation.