Ta-Yuan Chang

Prof. Ta-Yuan Chang

Department of Occupational Safety and Health, China Medical University, Taichung, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2011 in Environmental Health
Verified
Journal Article
Open access
PDF file
TCTa-Yuan Chang
Ta-Yuan Chang
CLChiu-Shong Liu
Chiu-Shong Liu
KHKuei-Hung Huang
Kuei-Hung Huang
RCRen-Yin Chen
Ren-Yin Chen
JLJim-Shoung Lai
Jim-Shoung Lai
BBBo-Ying Bao
Bo-Ying Bao
The association between occupational noise exposure and hypertension is inconsistent because of an exposure bias caused by outer-ear measurements of noise levels among workers. This study used hearing loss values (HLVs) measured at 4 kHz and 6 kHz in both ears as a biomarker to investigate the chronic effects of noise exposure on hypertension in 790 aircraft-manufacturing workers.

1 October 2009 in Environmental Research
Verified
Journal Article
Closed access
TCTa-Yuan Chang
Ta-Yuan Chang
YLYu-An Lai
Yu-An Lai
HHHsiu-Hui Hsieh
Hsiu-Hui Hsieh
JLJim-Shoung Lai
Jim-Shoung Lai
CLChiu-Shong Liu
Chiu-Shong Liu

6 March 2013 in American Journal of Epidemiology
Verified
Journal Article
Open access
PDF file
TCTa-Yuan Chang
Ta-Yuan Chang
Bing-Fang HwangBing-Fang Hwang
Bing-Fang Hwang
CLChiu-Shong Liu
Chiu-Shong Liu
RCRen-Yin Chen
Ren-Yin Chen
VWVen-Shing Wang
Ven-Shing Wang
JLJim-Shoung Lai
Jim-Shoung Lai
The associations between occupational noise exposure and hypertension remain controversial because of the differences in study designs, exposure assessments, and confounding controls. This prospective study investigated the relationship between noise exposure and the 10-year risk of hypertension. A cohort of 578 male workers in Taiwan was followed from 1998 to 2008. All subjects were divided into high-, intermediate-, and low-exposure groups on the basis of noise exposure assessment. Cox regression models were used to estimate the relative risks of hypertension after adjustment for potential confounders. During the 7,805 person-years of follow-up, 141 hypertension cases were identified. Significant increases of 3.2 (95% confidence interval (CI): 0.2, 6.2) mm Hg in systolic blood pressure and 2.5 (95% CI: 0.1, 4.8) mm Hg in diastolic blood pressure between the baseline and follow-up measurements were observed in the high-exposure group. Participants exposed to ≥85 A-weighted decibels (dBA) had a 1.93-fold (95% CI: 1.15, 3.22) risk of hypertension compared with those exposed to <80 dBA. There was a significant exposure-response pattern (P = 0.016) between the risk of hypertension and the stratum of noise exposure. Prolonged exposure to noise levels ≥85 dBA may increase males’ systolic and diastolic blood pressure levels. This association may translate into a higher incidence of hypertension.

13 October 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
TWTang-Chuan Wang
Tang-Chuan Wang
TCTa-Yuan Chang
Ta-Yuan Chang
Richard Sydney TylerRichard Sydney Tyler
Richard Sydney Tyler
YLYing-Ju Lin
Ying-Ju Lin
WLWen-Miin Liang
Wen-Miin Liang
MTMing-Hsui Tsai
Ming-Hsui Tsai
Long-term noise exposure often results in noise induced hearing loss (NIHL). Tinnitus, the generation of phantom sounds, can also result from noise exposure, although understanding of its underlying mechanisms are limited. Recent studies, however, are shedding light on the neural processes involved in NIHL and tinnitus, leading to potential new and innovative treatments. This review focuses on the assessment of NIHL, available treatments, and development of new pharmacologic and non-pharmacologic treatments based on recent studies of central auditory plasticity and adaptive changes in hearing. We discuss the mechanisms and maladaptive plasticity of NIHL, neuronal aspects of tinnitus triggers, and mechanisms such as tinnitus-associated neural changes at the cochlear nucleus underlying the generation of tinnitus after noise-induced deafferentation. We include observations from recent studies, including our own studies on associated risks and emerging treatments for tinnitus. Increasing knowledge of neural plasticity and adaptive changes in the central auditory system suggest that NIHL is preventable and transient abnormalities may be reversable, although ongoing research in assessment and early detection of hearing difficulties is still urgently needed. Since no treatment can yet reverse noise-related damage completely, preventative strategies and increased awareness of hearing health are essential.

16 May 2014 in Environmental Health
Verified
Journal Article
Open access
PDF file
TCTa-Yuan Chang
Ta-Yuan Chang
RBRob Beelen
Rob Beelen
SLSu-Fei Li
Su-Fei Li
TCTzu-I Chen
Tzu-I Chen
YLYen-Ju Lin
Yen-Ju Lin
CLChiu-Shong Liu
Chiu-Shong Liu
Epidemiological studies have reported the association between hypertension and exposure to road traffic noise, but the association between noise frequency characteristics is not clear. This study investigated the association between exposure to different frequency components of road traffic noise and the prevalence of hypertension in central Taiwan.

1 February 2011 in Science of The Total Environment
Verified
Journal Article
Closed access
TCTa-Yuan Chang
Ta-Yuan Chang
CLChiu-Shong Liu
Chiu-Shong Liu
BBBo-Ying Bao
Bo-Ying Bao
SLSu-Fei Li
Su-Fei Li
TCTzu-I Chen
Tzu-I Chen
YLYen-Ju Lin
Yen-Ju Lin