Reverse total shoulder arthroplasty (rTSA) is increasingly being used as a reliable option for various shoulder disorders with deteriorated rotator cuff and glenohumeral joints. The stemless humerus component for shoulder arthroplasties is evolving with theoretical advantages, such as preservation of the humeral bone stock and decreased risk of periprosthetic fractures, as well as clinical research demonstrating less intraoperative blood loss, reduced surgical time, a lower rate of intraoperative fractures, and improved center of rotation restoration. In particular, for anatomical total shoulder arthroplasty (aTSA), the utilization of stemless humeral implants is gaining consensus in younger patients. The current systematic review of 14 clinical studies (637 shoulders) demonstrated the clinical outcomes of stemless rTSA. Regarding shoulder function, the mean Constant-Murley Score (CS) improved from 28.3 preoperatively to 62.8 postoperatively. The pooled overall complication and revision rates were 14.3% and 6.3%, respectively. In addition, recent studies have shown satisfactory outcomes with stemless rTSA relative to stemmed rTSA. Therefore, shoulder surgeons may consider adopting stemless rTSA, especially in patients with sufficient bone quality. However, further long-term studies comparing survivorship between stemless and stemmed rTSA are required to determine the gold standard for selecting stemless rTSA.
16 January 2016 in Journal of Hand Surgery (European Volume)
Few randomized trials have shown how the placement of a palmar locking plate affects outcomes. The purpose of this study was to compare clinical and radiological outcomes of fixation using locking plates with different concepts for placement relative to the watershed line in a prospective randomized trial. Sixty-four patients with a displaced distal radius fracture were divided into two groups according to the plates used for fixation: distal-type (AcuLocTM, Group A) and proximal-type (VariAxTM, Group V). Wrist function including the range of motion and grip strength was compared at 1, 2, 3 and 6 months postoperatively. Loss of reduction was assessed radiologically. Both groups demonstrated overall satisfactory function at 6 months with no significant difference found between the groups. Minimal loss of reduction was demonstrated in both groups. Internal fixation using the palmar locking plates with two different placements provided satisfactory outcomes at 6-month follow-up, but our results indicate that plates placed distal to the watershed line may delay recovery of wrist motion.
Fragment-type glenoid bone loss is known to remodel after arthroscopic Bankart repair. To our knowledge, no studies have been reported about the morphologic changes of the erosion-type bone loss. To determine the morphologic changes of erosion-type glenoid bone loss after arthroscopic Bankart repair. Twenty-eight patients (mean age: 31 years) with traumatic anterior glenohumeral instability with an erosion-type glenoid bone loss <25% underwent arthroscopic Bankart repair. The minimum follow-up was 2 years. Pre- and postoperative bilateral computed tomography scans were performed in all patients. The width and surface area of the glenoid were measured by a software program and compared pre- and postoperatively. The recurrence rate was 7.1% (2 of 28 shoulders). The size of the bone loss was 7.2% ± 5.3% (mean ± standard deviation). The preoperative glenoid width and area were 24.9 ± 2.2 mm and 7.0 ± 0.8 cm2, respectively, and the postoperative ones (2 years after surgery) were 24.7 ± 2.2 mm and 6.8 ± 0.8 cm2, respectively. There were no significant differences between the pre- and postoperative glenoid width and area. Unlike the fragment-type bone loss, the erosion-type bone loss <25% did not show any morphologic changes of the glenoid at least 2 years after arthroscopic Bankart repair.