Taku Hatta

Dr. Taku Hatta


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
THTaku Hatta
Taku Hatta
HGHugo Giambini
Hugo Giambini
Kosuke UeharaKosuke Uehara
Kosuke Uehara
SOSeiji Okamoto
Seiji Okamoto
SCShigao Chen
Shigao Chen
KAKai-Nan An
Kai-Nan An

1 September 2018 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
KSKiyotsugu Shinagawa
Kiyotsugu Shinagawa
THTaku Hatta
Taku Hatta
NYNobuyuki Yamamoto
Nobuyuki Yamamoto
JKJun Kawakami
Jun Kawakami
YSYuki Shiota
Yuki Shiota
EIEiji Itoi
Eiji Itoi

Verified
Journal Article
Open access
PDF file
THTaku Hatta
Taku Hatta
RMRyosuke Mashiko
Ryosuke Mashiko
JKJun Kawakami
Jun Kawakami
GMGaku Matsuzawa
Gaku Matsuzawa
YOYohei Ogata
Yohei Ogata
WHWaku Hatta
Waku Hatta
Reverse total shoulder arthroplasty (rTSA) is increasingly being used as a reliable option for various shoulder disorders with deteriorated rotator cuff and glenohumeral joints. The stemless humerus component for shoulder arthroplasties is evolving with theoretical advantages, such as preservation of the humeral bone stock and decreased risk of periprosthetic fractures, as well as clinical research demonstrating less intraoperative blood loss, reduced surgical time, a lower rate of intraoperative fractures, and improved center of rotation restoration. In particular, for anatomical total shoulder arthroplasty (aTSA), the utilization of stemless humeral implants is gaining consensus in younger patients. The current systematic review of 14 clinical studies (637 shoulders) demonstrated the clinical outcomes of stemless rTSA. Regarding shoulder function, the mean Constant-Murley Score (CS) improved from 28.3 preoperatively to 62.8 postoperatively. The pooled overall complication and revision rates were 14.3% and 6.3%, respectively. In addition, recent studies have shown satisfactory outcomes with stemless rTSA relative to stemmed rTSA. Therefore, shoulder surgeons may consider adopting stemless rTSA, especially in patients with sufficient bone quality. However, further long-term studies comparing survivorship between stemless and stemmed rTSA are required to determine the gold standard for selecting stemless rTSA.

16 January 2016 in Journal of Hand Surgery (European Volume)
Verified
Journal Article
Closed access
HTH. Tanaka
H. Tanaka
THTaku Hatta
Taku Hatta
KSK. Sasajima
K. Sasajima
EIE. Itoi
E. Itoi
TAT. Aizawa
T. Aizawa
Few randomized trials have shown how the placement of a palmar locking plate affects outcomes. The purpose of this study was to compare clinical and radiological outcomes of fixation using locking plates with different concepts for placement relative to the watershed line in a prospective randomized trial. Sixty-four patients with a displaced distal radius fracture were divided into two groups according to the plates used for fixation: distal-type (AcuLocTM, Group A) and proximal-type (VariAxTM, Group V). Wrist function including the range of motion and grip strength was compared at 1, 2, 3 and 6 months postoperatively. Loss of reduction was assessed radiologically. Both groups demonstrated overall satisfactory function at 6 months with no significant difference found between the groups. Minimal loss of reduction was demonstrated in both groups. Internal fixation using the palmar locking plates with two different placements provided satisfactory outcomes at 6-month follow-up, but our results indicate that plates placed distal to the watershed line may delay recovery of wrist motion.

1 August 2017 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
TZTao Zhang
Tao Zhang
THTaku Hatta
Taku Hatta
ATAndrew R. Thoreson
Andrew R. Thoreson
CLCheng-Chang Lu
Cheng-Chang Lu
SSScott P. Steinmann
Scott P. Steinmann
chunfeng zhaochunfeng zhao
chunfeng zhao
Surgical repair is a common treatment for rotator cuff tear; however, the retear rate is high. A high degree of suture repair strength is important to ensure rotator cuff integrity for healing. The purpose of this study was to compare the mechanical performance of rotator cuffs repaired with a mesh suture versus traditional polydioxanone suture II and FiberWire sutures in a canine in vitro model. Seventy‐two canine shoulders were harvested. An infraspinatus tendon tear was created in each shoulder. Two suture techniques—simple interrupted sutures and two‐row suture bridge—were used to reconnect the infraspinatus tendon to the greater tuberosity, using three different suture types: Mesh suture, polydioxanone suture II, or FiberWire. Shoulders were loaded to failure under displacement control at a rate of 20 mm/min. Failure load was compared between suture types and techniques. Ultimate failure load was significantly higher in the specimens repaired with mesh suture than with polydioxanone suture II or FiberWire, regardless of suture technique. There was no significant difference in stiffness among the six groups, with the exception that FiberWire repairs were stiffer than polydioxanone suture II repairs with the simple interrupted technique. All specimens failed by suture pull‐out from the tendon. Based on our biomechanical findings, rotator cuff repair with the mesh suture might provide superior initial strength against failure compared with the traditional polydioxanone suture II or FiberWire sutures. Use of the mesh suture may provide increased initial fixation strength and decrease gap formation, which could result in improved healing and lower re‐tear rates following rotator cuff repair. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:987–992, 2018.

1 December 2020 in JSES International
Verified
Journal Article
Open access
LNLeonardo Hideto Nagaya
Leonardo Hideto Nagaya
NYNobuyuki Yamamoto
Nobuyuki Yamamoto
KSKiyotsugu Shinagawa
Kiyotsugu Shinagawa
THTaku Hatta
Taku Hatta
EIEiji Itoi
Eiji Itoi
Fragment-type glenoid bone loss is known to remodel after arthroscopic Bankart repair. To our knowledge, no studies have been reported about the morphologic changes of the erosion-type bone loss. To determine the morphologic changes of erosion-type glenoid bone loss after arthroscopic Bankart repair. Twenty-eight patients (mean age: 31 years) with traumatic anterior glenohumeral instability with an erosion-type glenoid bone loss <25% underwent arthroscopic Bankart repair. The minimum follow-up was 2 years. Pre- and postoperative bilateral computed tomography scans were performed in all patients. The width and surface area of the glenoid were measured by a software program and compared pre- and postoperatively. The recurrence rate was 7.1% (2 of 28 shoulders). The size of the bone loss was 7.2% ± 5.3% (mean ± standard deviation). The preoperative glenoid width and area were 24.9 ± 2.2 mm and 7.0 ± 0.8 cm2, respectively, and the postoperative ones (2 years after surgery) were 24.7 ± 2.2 mm and 6.8 ± 0.8 cm2, respectively. There were no significant differences between the pre- and postoperative glenoid width and area. Unlike the fragment-type bone loss, the erosion-type bone loss <25% did not show any morphologic changes of the glenoid at least 2 years after arthroscopic Bankart repair.