Christoph Groden

Prof. Dr. Christoph Groden


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2013 in Journal of Neuroimaging
Verified
Journal Article
Closed access
PDF file
AFAlex Förster
Alex Förster
INIngo Nölte
Ingo Nölte
HWHolger Wenz
Holger Wenz
MAMansour Al‐Zghloul
Mansour Al‐Zghloul
HKHans U. Kerl
Hans U. Kerl
CGChristoph Groden
Christoph Groden

15 February 2008 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
INIngo Nölte
Ingo Nölte
LGLars Gerigk
Lars Gerigk
MBMarc A. Brockmann
Marc A. Brockmann
AKAndre Kemmling
Andre Kemmling
CGChristoph Groden
Christoph Groden

26 May 2015 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
HWH. Wenz
H. Wenz
RWR. Wenz
R. Wenz
GEG. Ehrlich
G. Ehrlich
CGChristoph Groden
Christoph Groden
KSK. Schmieder
K. Schmieder
JFJ. Fontana
J. Fontana

1 April 2003
Verified
Journal Article
Closed access
CGChristoph Groden
Christoph Groden
CHChristian Hagel
Christian Hagel
GDGuenter Delling
Guenter Delling
HZHermann Zeumer
Hermann Zeumer

2 December 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
AYAlbert J Yoo
Albert J Yoo
SGSerdar Geyik
Serdar Geyik
MFMichael T Froehler
Michael T Froehler
CMChristoph Johannes Maurer
Christoph Johannes Maurer
TKTareq Kass-Hout
Tareq Kass-Hout
RGRishi Gupta
Rishi Gupta
Background Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. Objective To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. Methods Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b–3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a −10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0–2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). Results From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12–20). In the primary analysis population (n=107), eTICI 2b–3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority P<0.0001; post hoc superiority P<0.0001). First pass eTICI 2b–3 was observed in 73.8% (79/107), with first pass eTICI 2b67–3 in 69.2% (74/107) and eTICI 2c–3 in 48.6% (52/107). Median number of passes was 1 (IQR 1–2). Final eTICI 2b–3 rate was 99.1% (106/107); final eTICI 2b67–3 rate was 91.6% (98/107); final eTICI 2c–3 rate was 72.9% (78/107). Good outcome (90-day mRS score 0–2) was seen in 65.1% (69/106). Mortality was 9.4% (13/138) with sICH in 5.0% (7/139). Conclusions The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. Trial registration number NCT04514562.

15 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
AKAnna Klempka
Anna Klempka
ASAlexander Schröder
Alexander Schröder
PNPhilipp Neumayer
Philipp Neumayer
CGChristoph Groden
Christoph Groden
SCSven Clausen
Sven Clausen
SHSvetlana Hetjens
Svetlana Hetjens
This study provides an objective comparison of cranial computed tomography (CT) imaging quality and radiation dose between photon counting detectors (PCCTs) and energy-integrated detectors (EIDs). We retrospectively analyzed 158 CT scans from 76 patients, employing both detector types on the same individuals to ensure a consistent comparison. Our analysis focused on the Computed Tomography Dose Index and the Dose-Length Product together with the contrast-to-noise ratio and the signal-to-noise ratio for brain gray and white matter. We utilized standardized imaging protocols and consistent patient positioning to minimize variables. PCCT showed a potential for higher image quality and lower radiation doses, as highlighted by this study, thus achieving diagnostic clarity with reduced radiation exposure, underlining its significance in patient care, particularly for patients requiring multiple scans. The results demonstrated that while both systems were effective, PCCT offered enhanced imaging and patient safety in neuroradiological evaluations.