Michael Lee Farrell

Dr. Michael Lee Farrell

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in medRxiv
Verified
Preprint
Open access
PDF file
NSNikhil Shri Sahajpal
Nikhil Shri Sahajpal
AMAshis Kumar Mondal
Ashis Kumar Mondal
SASudha Ananth
Sudha Ananth
ANAllan Njau
Allan Njau
Pankaj AhluwaliaPankaj Ahluwalia
Pankaj Ahluwalia
RKRavindra Kolhe
Ravindra Kolhe
Background: The adoption of saliva as a specimen type for SARS-CoV-2 mass surveillance can significantly increase population compliance with decreased exposure risk for healthcare workers. However, studies evaluating the clinical performance of saliva compared to nasopharyngeal swab (NPS) samples have demonstrated conflicting results regardless of the collection being in healthcare or community settings. Further, pooled testing with saliva remains a challenge owing to the ambiguous sensitivity, limit of detection (LoD), and processing challenges. To overcome these limitations, SalivaAll protocol was developed and validated as a cost-effective measure that must be used on saliva collected in health care or community settings with pooling utility for SARS-CoV-2 mass surveillance. Methods: The study evaluated 429 matched NPS and saliva samples collected from 344 individuals in either healthcare or community setting. In phase I (protocol U), 240 matched NPS, and saliva samples were tested for SARS-CoV-2 detection by RT-PCR. In phase II (SalivaAll protocol), 189 matched NPS and saliva samples were tested, with an additional sample homogenization step for saliva before RNA extraction, followed by RT-PCR. Eighty-five saliva samples were evaluated with both protocols (U and SalivaAll). Subsequently, adopting SalivaAll protocol, a five-sample pooling strategy was evaluated for saliva samples based on FDA recommendations. Results: In phase I, 28.3% (68/240) samples tested positive for SARS-CoV-2 from either saliva, NPS, or both. The detection rate was lower in saliva compared to NPS samples (50.0% vs. 89.7%). In phase II, 50.2% (95/189) samples tested positive for SARS-CoV-2 from either saliva, NPS, or both. The detection rate for SARS-CoV-2 was higher in saliva compared to NPS testing (97.8% vs. 78.9%). Of the 85 saliva samples evaluated by both protocols, 57.6% (49) tested positive for SARS-CoV-2 with either protocol U, SalivaAll, or both. The detection rate was 100% for samples tested with SalivaAll, whereas it was 36.7% with protocol U. Also, the LoD with SalivaAll protocol was 20 copies/ml. The pooled testing approach demonstrated a 95% positive and 100% negative percent agreement. Conclusion: This single-site study demonstrated the variability of results reported in the literature for saliva samples, and found that the discrepancies are explained by processing challenges associated with saliva samples. We have optimized a protocol for saliva samples that results in higher sensitivity compared to NPS samples and also breaks the barrier to using pooled saliva testing for SARS-CoV-2. Summary: SalivaAll is a very sensitive (LoD 20 copies/ml) cost-effective test validated on saliva collected in health care and community settings with pooling utility and submitted for FDA Emergency Use Authorization.

5 November 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
SKSoohwan Kim
Soohwan Kim
NBNoah Baughman
Noah Baughman
MBMohamed Badawy
Mohamed Badawy
MAMargaret Armstrong
Margaret Armstrong
KWKristina Wayne
Kristina Wayne
MFMichael Lee Farrell
Michael Lee Farrell

21 September 2024 in Viruses
Verified
Journal Article
Open access
PDF file
MFMichael Lee Farrell
Michael Lee Farrell
ABAnton V Bryksin
Anton V Bryksin
EREmily Ryan
Emily Ryan
JLJessica Lin
Jessica Lin
NDNaima Djeddar
Naima Djeddar
MSMichael P Shannon
Michael P Shannon
At the beginning of the COVID-19 pandemic, the Georgia Institute of Technology made the decision to keep the university doors open for on-campus attendance. To manage COVID-19 infection rates, internal resources were applied to develop and implement a mass asymptomatic surveillance program. The objective was to identify infections early for proper follow-on verification testing, contact tracing, and quarantine/isolation as needed. Program success depended on frequent and voluntary sample collection from over 40,000 students, faculty, and staff personnel. At that time, the nasopharyngeal (NP) swab, not saliva, was the main accepted sample type for COVID-19 testing. However, due to collection discomfort and the inability to be self-collected, the NP swab was not feasible for voluntary and frequent self-collection. Therefore, saliva was selected as the clinical sample type and validated. A saliva collection kit and a sample processing and analysis workflow were developed. The results of a clinical sample-type comparison study between co-collected and matched NP swabs and saliva samples showed 96.7% positive agreement and 100% negative agreement. During the Fall 2020 and Spring 2021 semesters, 319,988 samples were collected and tested. The program resulted in maintaining a low overall mean positivity rate of 0.78% and 0.54% for the Fall 2020 and Spring 2021 semesters, respectively. For this high-throughput asymptomatic COVID-19 screening application, saliva was an exceptionally good sample type.