To address the issue of accommodating large-scale wind power integration into the grid, a unit commitment model for power systems based on an improved binary particle swarm optimization algorithm is proposed, considering frequency constraints and demand response (DR). First, incentive-based DR and price-based DR are introduced to enhance the flexibility of the demand side. To ensure the system can provide frequency support, the unit commitment model incorporates constraints such as the rate of change of frequency, frequency nadir, steady-state frequency deviation, and fast frequency response. Next, for the unit commitment planning problem, the binary particle swarm optimization algorithm is employed to solve the mixed nonlinear programming model of unit commitment, thus obtaining the minimum operating cost. The results show that after considering DR, the load becomes smoother compared to the scenario without DR participation, the overall level of load power is lower, and the frequency meets the safety constraint requirements. The results indicate that a comparative analysis of unit commitment in power systems under different scenarios verifies that DR can promote rational allocation of electricity load by users, thereby improving the operational flexibility and economic efficiency of the power system. In addition, the frequency variation considering frequency safety constraints has also been significantly improved. The improved binary particle swarm optimization algorithm has promising application prospects in solving the accommodation problem brought by large-scale wind power integration.
The parallel operation of multiple LCL-type converters will result in a deviation of the resonant frequency and resonance phenomena. The occurrence of harmonic resonance can cause problems such as an increase in harmonic voltage and current. This can lead to the malfunction of relay protection and automatic devices, causing damage to system equipment. In severe cases, it can cause accidents and threaten the safe operation of the power system. A hybrid damping active disturbance rejection control (HD-ADRC) method is proposed in this paper to suppress the harmonic resonance of parallel LCL-type converters. First, a third-order linear disturbance rejection controller (LADRC) including the linear extended-state observer and the error-feedback control rate is designed based on LCL-type converter model analysis. The proposed method considers the resonance couplings caused by both internal and external disturbances as the total disturbance, thus improving the anti-disturbance capabilities as well as the operational stability of converters in parallel. Then, a hybrid damping control is proposed to reconstruct the damping characteristics of converters to suppress the parallel resonance spike and reduce the resonance frequency offset. And the parameter selection of the control system is optimized through a stability analysis of the tracking performance and anti-disturbance performance of the HD-ADRC controller. Finally, all the theoretical considerations are verified by simulation and experimental results based on the Matlab/Simulink 2018B and dSpace platform. The simulation and experimental results show that the PI controller gives a THD of 5.33%, which is reduced to 4.66% by employing the HD-LADRC, indicating an improved decoupling between the converters working in parallel with the proposed control scheme.