Mark D. Bain

Dr. Mark D. Bain


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2017 in Neurosurgery
Verified
Journal Article
Closed access
PDF file
MLMin Lang
Min Lang
NMNina Z. Moore
Nina Z. Moore
PRPeter A Rasmussen
Peter A Rasmussen
MBMark D. Bain
Mark D. Bain
BACKGROUND: The guideline for treating unruptured brain arteriovenous malformations (ubAVMs) remains controversial. A Randomized Trial of Unruptured Brain Arteriovenous Malformations (ARUBA) reported lower risk of stroke or death with conservative management compared to interventional treatment. There were numerous limitations to the study, including short follow-up period and disproportionate number of patients treated with surgery and embolization. OBJECTIVE: To evaluate whether treatment of ARUBA-eligible patients have acceptable outcomes at our institution. METHODS: Retrospective analysis was performed on 673 patients with brain AVMs treated at our institution between 2001 and 2014. One hundred five patients were ARUBA eligible and included in the study. Patients were divided into the microsurgery or Gamma Knife Radiosurgery (GKS; Elekta, Stockholm, Sweden) arm depending on their final treatment. Mean follow-up period was 43 mo (range 4-136 mo). Primary outcome was stroke or death. RESULTS: A total of 8 (7.6%) patients had a stroke or died. The overall risk of stroke or death was 11.4% (5 of 44 patients) for the microsurgery arm and 4.9% (3 of 61 patients) for the GKS arm. The annual rates of stroke or death were 2.1%, 4.0%, and 1.2% for the entire patient cohort, microsurgery arm, and GKS arm, respectively. AVM obliteration rates at the end of the follow-up period were 95.5% and 47.5% for the microsurgery and GKS arms, respectively. CONCLUSION: We report a lower overall risk of stroke or death in our ARUBA-eligible patients following treatment than ARUBA. Our results suggest that microsurgery and GKS may be appropriate treatments for patients with ubAVM.

1 January 2016 in Stroke
Verified
Journal Article
Closed access
SJSeby John
Seby John
KWKevin M. Walsh
Kevin M. Walsh
FHFerdinand K. Hui
Ferdinand K. Hui
SSSophia Sundararajan
Sophia Sundararajan
SSScott Silverman
Scott Silverman
MBMark D. Bain
Mark D. Bain

1 June 2023 in Journal of Neurosurgery
Verified
Journal Article
Closed access
PDF file
AKAhmed Kashkoush
Ahmed Kashkoush
MEMohamed E. El-Abtah
Mohamed E. El-Abtah
SSShaarada Srivatsa
Shaarada Srivatsa
ADAnsh Desai
Ansh Desai
MDMark Davison
Mark Davison
MBMark D. Bain
Mark D. Bain
OBJECTIVE: Woven EndoBridge (WEB) intrasaccular flow disruptors and stent-assisted coiling (SAC) are viable endovascular treatment options for wide-neck bifurcation intracranial aneurysms (WNBAs). Data directly comparing these two treatment options are limited. The authors aimed to compare radiographic occlusion rates and complication profiles between patients who received WEB and those who received SAC for WNBAs. METHODS: Retrospective review of a prospectively maintained cerebrovascular procedural database was performed at a single academic medical center between 2017 and 2021. Patients were included if they underwent WEB embolization or SAC of an unruptured WNBA. SAC patients were propensity matched to WEB-embolized patients on the basis of aneurysm morphology. Complete and adequate (complete occlusion or residual neck remnant) occlusion rates at last angiographic follow-up, as well as periprocedural complications, were compared between the two groups. A cost comparison was performed for a typical 5-mm WNBA treated with WEB versus SAC by using manufacturer-suggested retail prices. RESULTS: Thirty-five WEB and 70 SAC patients were included. Aneurysm width, neck size, and dome-to-neck ratio were comparable between groups. Follow-up duration was significantly longer in the SAC group (median [interquartile range] 545 [202–834] days vs 228 [177–494] days, p < 0.001, Mann-Whitney U-test). Complete (66% of WEB patients vs 69% of SAC patients) and adequate (94% WEB vs 91% SAC) occlusion rates were similar between groups at the last available angiographic follow-up (p = 0.744, chi-square test). Complete occlusion rates were comparable on Cox regression analysis after correction for follow-up duration (hazard ratio 1.5, 95% CI 0.8–3.1). Average time to residual aneurysm or neck formation was not statistically different between treatment groups (613 days for SAC patients vs 347 days for WEB patients, p = 0.225, log-rank test). Periprocedural complications trended higher in the SAC group (0% WEB vs 9% SAC, p = 0.175, Fisher exact test), although this finding was not significant. The equipment costs for a typical SAC case were estimated at $18,950, whereas the costs for a typical WEB device case were estimated at $18,630. CONCLUSIONS: Midterm complete and adequate occlusion rates were similar between patients treated with WEB and those treated with SAC. Given these comparable outcomes, there may be equipoise in treatment options for WNBAs.

1 September 2017 in World Neurosurgery
Verified
Journal Article
Closed access
MLMin Lang
Min Lang
NMNina Z. Moore
Nina Z. Moore
AWAlex M. Witek
Alex M. Witek
VKVarun R. Kshettry
Varun R. Kshettry
MBMark D. Bain
Mark D. Bain

14 June 2022 in Operative Neurosurgery
Verified
Journal Article
Closed access
RARebecca L. Achey
Rebecca L. Achey
PSPranay Soni
Pranay Soni
AKAhmed Kashkoush
Ahmed Kashkoush
MDMark Davison
Mark Davison
EKEfstathios Kondylis
Efstathios Kondylis
MBMark D. Bain
Mark D. Bain
BACKGROUND: Minimally invasive surgery (MIS) for intracranial pathology minimizes surgical morbidity but can come at the cost of operator ergonomics and technical surgical success. Here, the authors present a case series to report the first use of a novel 15-mm tubular retraction system with integrated lighting and visualization capabilities for MIS access to intracranial lesions. OBJECTIVE: To demonstrate feasibility and effectiveness of the 15-mm Aurora Surgiscope (Integra Lifesciences) for intracranial MIS approaches. METHODS: The 15-mm Aurora Surgiscope facilitated MIS approach to gain access to intraparenchymal pathologies. The device consists of a tubular access system with integrated light source and a reusable control unit that modifies video parameters. The port was inserted along a preplanned trajectory through a mini-craniotomy. Bimanual access allowed the surgeon to comfortably dissect/resect lesional tissue using high-quality video. RESULTS: Four patients are presented. In cases 1 and 2, the authors evacuated acute intracerebral hemorrhages. Both had <15 cc hemorrhage with improved or stable neurological examination. In case 3, the authors performed gross total resection of a cerebellar pilocytic astrocytoma. In case 4, the authors resected a mesial posterior temporal cavernoma. No perioperative/technical complications were noted. CONCLUSION: The Aurora Surgiscope system is a novel integrated tubular retraction, lighting, and visualization system that allows access to a wide variety of pathologies using a MIS approach. The Surgiscope allows the surgeon to use bimanual dexterity through a small access port while limiting the need for additional equipment such as microscope, exoscope, or endoscope.

15 December 2020 in Operative Neurosurgery
Verified
Journal Article
Open access
PDF file
DCDaniel D Cavalcanti
Daniel D Cavalcanti
NDNader Delavari
Nader Delavari
HRHoward A Riina
Howard A Riina
E(Endovascular Neurosurgery Research Group (ENRG)
Endovascular Neurosurgery Research Group (ENRG)
AAAdam Arthur
Adam Arthur
JWJonathan White
Jonathan White
Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.