Richard Skifton

Dr. Richard Skifton

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
NKNiharika Karnik
Niharika Karnik
MAMohammad G. Abdo
Mohammad G. Abdo
CECarlos E. Estrada-Perez
Carlos E. Estrada-Perez
JYJun Soo Yoo
Jun Soo Yoo
JCJoshua J. Cogliati
Joshua J. Cogliati
KMKrithika Manohar
Krithika Manohar
The deployment of extensive sensor arrays in nuclear reactors is infeasible due to challenging operating conditions and inherent spatial limitations. Strategically placing sensors within defined spatial constraints is essential for the reconstruction of reactor flow fields and the creation of nuclear digital twins. We develop a data-driven technique that incorporates constraints into an optimization framework for sensor placement, with the primary objective of minimizing reconstruction errors under noisy sensor measurements. The proposed greedy algorithm optimizes sensor locations over high-dimensional grids, adhering to user-specified constraints. We demonstrate the efficacy of optimized sensors by exhaustively computing all feasible configurations for a low-dimensional dynamical system. To validate our methodology, we apply the algorithm to the Out-of-Pile Testing and Instrumentation Transient Water Irradiation System (OPTI-TWIST) prototype capsule. This capsule is electrically heated to emulate the neutronic effect of the nuclear fuel. The TWIST prototype that will eventually be inserted in the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory (INL), serves as a practical demonstration. The resulting sensor-based temperature reconstruction within OPTI-TWIST demonstrates minimized error, provides probabilistic bounds for noise-induced uncertainty, and establishes a foundation for communication between the digital twin and the experimental facility.

8 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
NKNiharika Karnik
Niharika Karnik
CWCongjian Wang
Congjian Wang
Palash Kumar BhowmikPalash Kumar Bhowmik
Palash Kumar Bhowmik
JCJoshua J. Cogliati
Joshua J. Cogliati
SPSilvino A Balderrama Prieto
Silvino A Balderrama Prieto
Mohammad G. AbdoMohammad G. Abdo
Mohammad G. Abdo
Nuclear power plants (NPPs) require continuous monitoring of various systems, structures, and components to ensure safe and efficient operations. The critical safety testing of new fuel compositions and the analysis of the effects of power transients on core temperatures can be achieved through modeling and simulations. They capture the dynamics of the physical phenomenon associated with failure modes and facilitate the creation of digital twins (DTs). Accurate reconstruction of fields of interest (e.g., temperature, pressure, velocity) from sensor measurements is crucial to establish a two-way communication between physical experiments and models. Sensor placement is highly constrained in most nuclear subsystems due to challenging operating conditions and inherent spatial limitations. This study develops optimized data-driven sensor placements for full-field reconstruction within reactor and steam generator subsystems of NPPs. Optimized constrained sensors reconstruct field of interest within a tri-structural isotropic (TRISO) fuel irradiation experiment, a lumped parameter model of a nuclear fuel test rod and a steam generator. The optimization procedure leverages reduced-order models of flow physics to provide a highly accurate full-field reconstruction of responses of interest, noise-induced uncertainty quantification and physically feasible sensor locations. Accurate sensor-based reconstructions establish a foundation for the digital twinning of subsystems, culminating in a comprehensive DT aggregate of an NPP.

15 December 2017 in Instrumentation Science & Technology
Verified
Journal Article
Closed access
RSRichard Skifton
Richard Skifton
JPJoe Palmer
Joe Palmer
PCPattrick Calderoni
Pattrick Calderoni
A detailed description is provided for the optimization of heat treatment and calibrating procedure for Idaho National Laboratory’s high temperature irradiation resistant thermocouples (HTIR-TC). Also discussed is the implication of the procedures on the overall performance of the HTIR-TC finished product; in particular, for the case of long lead sections that are typical of sensors deployed in nuclear reactors. The effect on the measurement accuracy of fluctuations of the reference temperature and localized heating along the sensor lead is also investigated. A calibration graphical user interface (GUI) and accompanying script is presented for unifying the calibration process. A fifth-order polynomial function was found to be best for fitting HTIR-TC calibration data. The performance of the HTIR-TCs subject to the optimized heat treatment and calibration procedures is shown to be robust and consistent with other TC industry standards. Electromotive force curves versus length of the TC are presented to clarify positioning of TCs in general and how its effect on the calibrated temperatures.

19 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KFKiyo T. Fujimoto
Kiyo T. Fujimoto
LHLance A. Hone
Lance A. Hone
KMKory D. Manning
Kory D. Manning
RSRobert D. Seifert
Robert D. Seifert
DEDavid Estrada
David Estrada
DEDavid Estrada
David Estrada
Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

1 December 2013
Verified
Report
Closed access
PDF file
PSPiyush Sabharwall
Piyush Sabharwall
RSRichard Skifton
Richard Skifton
CSCarl Stoots
Carl Stoots
EKEung Soo Kim
Eung Soo Kim
TCThomas Conder
Thomas Conder
Currently, computational fluid dynamics (CFD) is widely used in the nuclear thermal hydraulics field for design and safety analyses. To validate CFD codes, high quality multi dimensional flow field data are essential. The Matched Index of Refraction (MIR) Flow Facility at Idaho National Laboratory has a unique capability to contribute to the development of validated CFD codes through the use of Particle Image Velocimetry (PIV). The significance of the MIR facility is that it permits non intrusive velocity measurement techniques, such as PIV, through complex models without requiring probes and other instrumentation that disturb the flow. At the heart of any PIV calculation is the cross-correlation, which is used to estimate the displacement of particles in some small part of the image over the time span between two images. This image displacement is indicated by the location of the largest peak. In the MIR facility, uncertainty quantification is a challenging task due to the use of optical measurement techniques. Currently, this study is developing a reliable method to analyze uncertainty and sensitivity of the measured data and develop a computer code to automatically analyze the uncertainty/sensitivity of the measured data. The main objective of this study is to develop amore » well established uncertainty quantification method for the MIR Flow Facility, which consists of many complicated uncertainty factors. In this study, the uncertainty sources are resolved in depth by categorizing them into uncertainties from the MIR flow loop and PIV system (including particle motion, image distortion, and data processing). Then, each uncertainty source is mathematically modeled or adequately defined. Finally, this study will provide a method and procedure to quantify the experimental uncertainty in the MIR Flow Facility with sample test results. « less

9 May 2023 in Frontiers in Energy Research
Verified
Journal Article
Open access
RSRichard Skifton
Richard Skifton
This article presents an instability model for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Here the term instability defines the superposition of both drift and inhomogeneity of TC thermoelements occurring simultaneously. The HTIR-TC is an advanced thermocouple (TC) that uses the refractory metals niobium and molybdenum as sensing thermoelements for generating electromotive force (EMF) in a field of neutrons and at temperatures upward of 1,600°C. In the Advanced Gas Reactor (AGR) 5/6/7 tests conducted at Idaho National Laboratory’s Advanced Test Reactor (ATR), the HTIR-TCs showed low to moderate instability throughout the life of the test. The instability model reveals that HTIR-TCs can, when the operating temperature of the reactor fuel is normal, maintain performance throughout an 18-month refueling cycle typical of nuclear power plants, reflecting an instability of less than ±1%. The HTIR-TC is also qualified for incorporation into a test fixture during the testing of new fuels.