Ganesh Adluru

Ganesh Adluru


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2013 in Physics in Medicine & Biology
Verified
Journal Article
Open access
Sajan Goud LingalaSajan Goud Lingala
Sajan Goud Lingala
EDEdward DiBella
Edward DiBella
GAGanesh Adluru
Ganesh Adluru
CMChristopher McGann
Christopher McGann
MJMathews Jacob
Mathews Jacob
The clinical utility of myocardial perfusion MR imaging (MPI) is often restricted by the inability of current acquisition schemes to simultaneously achieve high spatio-temporal resolution, good volume coverage, and high signal to noise ratio. Moreover, many subjects often find it difficult to hold their breath for sufficiently long durations making it difficult to obtain reliable MPI data. Accelerated acquisition of free breathing MPI data can overcome some of these challenges. Recently, an algorithm termed as k - t SLR has been proposed to accelerate dynamic MRI by exploiting sparsity and low rank properties of dynamic MRI data. The main focus of this paper is to further improve k - t SLR and demonstrate its utility in considerably accelerating free breathing MPI. We extend its previous implementation to account for multi-coil radial MPI acquisitions. We perform k - t sampling experiments to compare different radial trajectories and determine the best sampling pattern. We also introduce a novel augmented Lagrangian framework to considerably improve the algorithm's convergence rate. The proposed algorithm is validated using free breathing rest and stress radial perfusion data sets from two normal subjects and one patient with ischemia. k - t SLR was observed to provide faithful reconstructions at high acceleration levels with minimal artifacts compared to existing MPI acceleration schemes such as spatio-temporal constrained reconstruction and k - t SPARSE/SENSE.

21 August 2021 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
JLJohnathan Le
Johnathan Le
YTYe Tian
Ye Tian
JMJason Mendes
Jason Mendes
BWBrent Wilson
Brent Wilson
MIMark Ibrahim
Mark Ibrahim
GAGanesh Adluru
Ganesh Adluru

11 February 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YTYe Tian
Ye Tian
JMJason Mendes
Jason Mendes
APApoorva Pedgaonkar
Apoorva Pedgaonkar
MIMark Ibrahim
Mark Ibrahim
LJLeif Jensen
Leif Jensen
GAGanesh Adluru
Ganesh Adluru
Dynamic contrast enhanced MRI of the heart typically acquires 2–4 short-axis (SA) slices to detect and characterize coronary artery disease. This acquisition scheme is limited by incomplete coverage of the left ventricle. We studied the feasibility of using radial simultaneous multi-slice (SMS) technique to achieve SA, 2-chamber and/or 4-chamber long-axis (2CH LA and/or 4CH LA) coverage with and without electrocardiography (ECG) gating using a motion-robust reconstruction framework. 12 subjects were scanned at rest and/or stress, free breathing, with or without ECG gating. Multiple sets of radial SMS k-space were acquired within each cardiac cycle, and each SMS set sampled 3 parallel slices that were either SA, 2CH LA, or 4CH LA slices. The radial data was interpolated onto Cartesian space using an SMS GRAPPA operator gridding method. Self-gating and respiratory states binning of the data were done. The binning information as well as a pixel tracking spatiotemporal constrained reconstruction method were applied to obtain motion-robust image reconstructions. Reconstructions with and without the pixel tracking method were compared for signal-to-noise ratio and contrast-to-noise ratio. Full coverage of the heart (at least 3 SA and 3 LA slices) during the first pass of contrast at every heartbeat was achieved by using the radial SMS acquisition. The proposed pixel tracking reconstruction improves the average SNR and CNR by 21% and 30% respectively, and reduces temporal blurring for both gated and ungated acquisitions. Acquiring simultaneous multi-slice SA, 2CH LA and/or 4CH LA myocardial perfusion images in every heartbeat is feasible in both gated and ungated acquisitions. This can add confidence when detecting and characterizing coronary artery disease by revealing ischemia in different views, and by providing apical coverage that is improved relative to SA slices alone. The proposed pixel tracking framework improves the reconstruction while adding little computational cost.

3 June 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
YTYe Tian
Ye Tian
JMJason Mendes
Jason Mendes
BWBrent Wilson
Brent Wilson
ARAlexander Ross
Alexander Ross
RRRavi Ranjan
Ravi Ranjan
GAGanesh Adluru
Ganesh Adluru

1 May 2021 in Medical Image Analysis
Verified
Journal Article
Closed access
SHSeyyedKazem HashemizadehKolowri
SeyyedKazem HashemizadehKolowri
RCRong-Rong Chen
Rong-Rong Chen
GAGanesh Adluru
Ganesh Adluru
DIDouglas Dean III
Douglas Dean III
EWElisabeth A. Wilde
Elisabeth A. Wilde
EDEdward DiBella
Edward DiBella

21 June 2022 in Medical Physics
Verified
Journal Article
Closed access
JLJohnathan V. Le
Johnathan V. Le
JMJason K. Mendes
Jason K. Mendes
NMNicholas McKibben
Nicholas McKibben
BWBrent D. Wilson
Brent D. Wilson
MIMark Ibrahim
Mark Ibrahim
GAGanesh Adluru
Ganesh Adluru