Fernando Freitas Portella

Prof. Dr. Fernando Freitas Portella


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2015 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
FCFabrício Mezzomo Collares
Fabrício Mezzomo Collares
FPFernando Freitas Portella
Fernando Freitas Portella
SRS. B. Rodrigues
S. B. Rodrigues
RCRoger Keller Celeste
Roger Keller Celeste
VLVicente Leitune
Vicente Leitune
SSS. M. W. Samuel
S. M. W. Samuel

1 October 2019 in International Journal of Medical Informatics
Verified
Journal Article
Closed access
RTRodrigo Alves Tubelo
Rodrigo Alves Tubelo
FPFernando Freitas Portella
Fernando Freitas Portella
MGMarco Antônio Gelain
Marco Antônio Gelain
MOMônica Maria Celestina de Oliveira
Mônica Maria Celestina de Oliveira
AOAna Emília Figueiredo de Oliveira
Ana Emília Figueiredo de Oliveira
MPMaria Eugênia Bresolin Pinto
Maria Eugênia Bresolin Pinto

1 October 2011 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
VLVicente Leitune
Vicente Leitune
FPFernando Freitas Portella
Fernando Freitas Portella
PBPriscila Veit Bohn
Priscila Veit Bohn
FCFabrício Mezzomo Collares
Fabrício Mezzomo Collares
SSSusana Maria Werner Samuel
Susana Maria Werner Samuel
The aim of this study was to evaluate the influence of applying 2% chlorhexidine for 30 seconds after phosphoric acid conditioning of dentin on the immediate and long-term bond strengths in deciduous teeth. The occlusal enamel was removed from 40 human sound deciduous molars, which were exfoliated by natural means, and the dentin was conditioned with 37% phosphoric acid for 15 seconds and washed with running water. The specimens were divided into two groups of 20 teeth. The test group received an application of 2% chlorhexidine for 30 seconds prior to a three-step etch-and-rinse adhesive system, whereas the control group received only the adhesive system. Three cylindrical restorations were made with a composite resin for each tooth. Ten teeth in each group were submitted to a microshear bond strength test after 24 hours, while the remaining teeth were stored in distilled water at 37 °C for 6 months before testing the microshear bond strength. The test group had a higher bond strength than did the control group after 6 months of storage. No statistical differences were found when groups with the same dentin treatment were compared at different times. Short applications of chlorhexidine at low concentrations prevent hybrid layer degradation and positively affect bond strength over time.

1 December 2013 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
FCFabrício Mezzomo Collares
Fabrício Mezzomo Collares
MKMariana Klein
Mariana Klein
PSPaula Dapper Santos
Paula Dapper Santos
FPFernando Freitas Portella
Fernando Freitas Portella
FOFabricio Ogliari
Fabricio Ogliari
SSSusana Maria Werner Samuel
Susana Maria Werner Samuel
Key words: Tungsten; Ytterbium; Barium; Root canal filling materials

11 November 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LTLucas Henrique Telles
Lucas Henrique Telles
FPFernando Freitas Portella
Fernando Freitas Portella
ERElken Gomes Rivaldo
Elken Gomes Rivaldo
To compare the longevity and marginal bone loss of narrow-diameter (≤3.3-mm) versus standard-diameter implants supporting single crowns. The MEDLINE (via PubMed), Scopus, and SciELO databases were searched for relevant publications. In addition, the scientific references provided by each of the implant companies that appeared in the search were reviewed. Intervention studies comparing longevity and bone loss between narrow-diameter and standard-diameter implants were included. The search was limited to in vivo studies in humans. The query returned 1931 results, of which 4 met the inclusion criteria. The implant success rate ranged from 93.8% to 100% over a maximum follow-up of 3 years, with no difference between narrow- and standard-diameter implants. Meta-analysis of all included studies showed greater bone loss in narrow-diameter implants as compared with standard ones; however, when analysis was restricted to randomized trials, no such difference was present. The meta-analysis showed no difference in longevity between narrow implants and standard implants when supporting single crowns. However, narrow-diameter implants may be associated with greater marginal bone loss. These findings should be regarded cautiously due to the short follow-up duration and methodological heterogeneity of the primary studies.

14 March 2013 in Gerodontology
Verified
Journal Article
Closed access
PDF file
FPFernando Freitas Portella
Fernando Freitas Portella
ARAline W. Rocha
Aline W. Rocha
DHDaniel C. Haddad
Daniel C. Haddad
CFCarmem B.B. Fortes
Carmem B.B. Fortes
FHFernando N. Hugo
Fernando N. Hugo
SSSusana M.W. Samuel
Susana M.W. Samuel