Ahmed I Masoud

Dr. Ahmed I Masoud

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
BABashair A. Alsaud
Bashair A. Alsaud
MHMaher Saeed Hajjaj
Maher Saeed Hajjaj
AMAhmed I Masoud
Ahmed I Masoud
ENEnsanya A. Abou Neel
Ensanya A. Abou Neel
DADalia Abdullah Abuelenain
Dalia Abdullah Abuelenain
ALAmal Linjawi
Amal Linjawi
Background: We aim to evaluate the effect of surface conditioning, bonding agents and composite types on surface roughness (SR) and shear bond strength (SBS) of clear aligner composite attachments bonded to ceramics. Methods: One hundred and eighty IPS e.max CAD specimens were prepared. For SR, 60 specimens were divided according to surface conditioning (n = 15) into four groups: control, 9.6% hydrofluoric acid (HFA), 37% phosphoric acid (PhA), air abrasion (AA). SR was measured using a Profilometer and Atomic Force Microscopy. For SBS, 120 specimens were divided according to conditioning methods (n = 40) (9.6% HFA and 37% PhA or AA), then according to bonding agents (n = 20) (Assure universal bond (AUB) or Single bond universal (SBU)) and then according to composite type (n = 10): Filtek™ Z350 and Filtek™ Z350 XT flowable composite. SBS was measured using Instron testing machine. Descriptive and group comparison were calculated (p < 0.05). Results: AA had the highest SR, while the control had the lowest SR (p < 0.05). HFA had the highest, but insignificant SBS, followed by AA (p > 0.05). AUB had higher SBS than SBU (p < 0.001). Filtek™ Z350 produced higher SBS than Filtek™ Z350 XT flowable composite (p < 0.01). Conclusion: The combination of AA, AUB, and Filtek Z350 produced the highest SBS, followed by HFA, AUB, and Filtek Z350.

15 May 2019 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
AMAhmed I Masoud
Ahmed I Masoud
PPPallavi P. Patwari
Pallavi P. Patwari
PAPranshu A. Adavadkar
Pranshu A. Adavadkar
HAHenry Arantes
Henry Arantes
CPChang Park
Chang Park
DCDavid. W. Carley
David. W. Carley
Study Objectives:Polysomnography (PSG) is considered the gold standard in the diagnosis of sleep apnea. In pediatric patients, because of limited availability and access to laboratory-based PSG, th...

1 November 2014 in The Angle Orthodontist
Verified
Journal Article
Closed access
AMAhmed I Masoud
Ahmed I Masoud
TTT. Peter Tsay
T. Peter Tsay
EBEllen BeGole
Ellen BeGole
ABAna K. Bedran-Russo
Ana K. Bedran-Russo
Objectives: To compare the following over a period of 8 weeks: (1) force decay between thermoplastic (TP) and thermoset (TS) elastomeric chains; (2) force decay between light (200-g) and heavy (350-g) initial forces; and (3) force decay between direct chains and chain loops (stretched from one pin around the second pin and back to the first pin). Materials and Methods: TP and TS chains were obtained from American Orthodontics™ (AOTP, AOTS) and ORMCO™ (OrTP, OrTS). Each of the four chain groups was subdivided into four subgroups with 10 specimens per subgroup: (1) direct chains light force, (2) direct chains heavy force, (3) chain loops light force, and (4) chain loops heavy force. The experiment was performed in artificial saliva (pH of 6.75) at 37°C. Results: A significant difference was found between TP and TS chains, with an average mean difference of around 20% more force decay found in the TP chains ( P < .001, α = .05). There was no significant difference between direct chains and chain loops except in OrTP, in which direct chains showed more force decay. There was also no significant difference in force decay identified when using light vs heavy forces. Conclusions: TS chains decayed less than TP chains, and chain loop retraction was beneficial only when using OrTP chains. Contrary to the interchangeable use of TP and TS chains in the published literature and in clinical practice, this study demonstrates that they perform differently under stress and that a clear distinction should be made between the two.

19 September 2016 in Cranio®
Verified
Journal Article
Closed access
AMAhmed I Masoud
Ahmed I Masoud
GJGregory W. Jackson
Gregory W. Jackson
DCDavid W. Carley
David W. Carley
Dentists can be the first professionals to recognize a patient's potential sleep problem since they typically have more frequent contact with their patients than do physicians. It is important that dentists have a reasonable understanding of sleep disorders and how to assess their patients if they suspect such a problem so that a timely referral can be made or treatment can be provided as appropriate. To review the key literature relevant to sleep-disordered breathing (SDB) characteristics and diagnosis, including history, examination, and investigation with an emphasis on radiographic airway analyses. The authors present a concise explanation of SDB conditions and an outline for thorough patient examination and evaluation, including radiographic airway analyses. Limited two-dimensional and three-dimensional norms exist for adult patients with no SDB and even less so for children. Much more research is needed, particularly in the pediatric population.

1 December 2018 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
AAAbdurahman H. Alwadei
Abdurahman H. Alwadei
MGMaria Therese S. Galang-Boquiren
Maria Therese S. Galang-Boquiren
BKBudi Kusnoto
Budi Kusnoto
MVMaria Grace Costa Viana
Maria Grace Costa Viana
ELEdward Y. Lin
Edward Y. Lin
AMAhmed I Masoud
Ahmed I Masoud

5 August 2020 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
AMAhmed I Masoud
Ahmed I Masoud
AAAbdurahman H. Alwadei
Abdurahman H. Alwadei
LGLena F. Gowharji
Lena F. Gowharji
CPChang G. Park
Chang G. Park
DCDavid W. Carley
David W. Carley