Aleena Azam

Dr. Aleena Azam

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2024 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
AAAleena Azam
Aleena Azam
SKSorel Kurbegovic
Sorel Kurbegovic
ECEsben Andreas Carlsen
Esben Andreas Carlsen
TAThomas Lund Andersen
Thomas Lund Andersen
VLVibeke André Larsen
Vibeke André Larsen
Andreas KjaerAndreas Kjaer
Andreas Kjaer
Background: Treatment of patients with low-grade and high-grade gliomas is highly variable due to the large difference in survival expectancy. New non-invasive tools are needed for risk stratification prior to treatment. The urokinase plasminogen activator receptor (uPAR) is expressed in several cancers, associated with poor prognosis and may be non-invasively imaged using uPAR-PET. We aimed to investigate the uptake of the uPAR-PET tracer [68Ga]Ga-NOTA-AE105 in primary gliomas and establish its prognostic value regarding overall survival (OS), and progression-free survival (PFS). Additionally, we analyzed the proportion of uPAR-PET positive tumors to estimate the potential number of candidates for future uPAR-PRRT. Methods: In a prospective phase II clinical trial, 24 patients suspected of primary glioma underwent a dynamic 60-min PET/MRI following the administration of approximately 200 MBq (range: 83–222 MBq) [68Ga]Ga-NOTA-AE105. Lesions were considered uPAR positive if the tumor-to-background ratio, calculated as the ratio of TumorSUVmax-to-Normal-BrainSUVmean tumor-SUVmax-to-background-SUVmean, was ≥ 2.0. The patients were followed over time to assess OS and PFS and stratified into high and low uPAR expression groups based on TumorSUVmax. Results: Of the 24 patients, 16 (67%) were diagnosed with WHO grade 4 gliomas, 6 (25%) with grade 3, and 2 (8%) with grade 2. Two-thirds of all patients (67%) presented with uPAR positive lesions and 94% grade 4 gliomas. At median follow up of 18.8 (2.1–45.6) months, 19 patients had disease progression and 14 had died. uPAR expression dichotomized into high and low, revealed significant worse prognosis for the high uPAR group for OS and PFS with HR of 14.3 (95% CI, 1.8-112.3; P = 0.011), and HR of 26.5 (95% CI, 3.3–214.0; P = 0.0021), respectively. uPAR expression as a continuous variable was associated with worse prognosis for OS and PFS with HR of 2.7 (95% CI, 1.5–4.8; P = 0.0012), and HR of 2.5 (95% CI, 1.5–4.2; P = 0.00073), respectively. Conclusions: The majority of glioma patients and almost all with grade 4 gliomas displayed uPAR positive lesions underlining the feasibility of 68Ga-NOTA-AE105 PET/MRI in gliomas. High uPAR expression is significantly correlated with worse survival outcomes for patients. Additionally, the high proportion of uPAR positive gliomas underscores the potential of uPAR-targeted radionuclide therapy in these patients. Trail Registration: EudraCT No: 2016-002417-21; the Scientific Ethics Committee: H-16,035,303; the Danish Data Protection Agency: 2012-58-0004; clinical trials registry: NCT02945826, 26Oct2016, URL: https://classic.clinicaltrials.gov/ct2/show/NCT02945826.

3 June 2025 in Neurosurgery
Verified
Journal Article
Open access
JSJane Skjøth-Rasmussen
Jane Skjøth-Rasmussen
AAAleena Azam
Aleena Azam
KJKarina Juhl
Karina Juhl
SGSara Ginsborg
Sara Ginsborg
MSMartin Kryspin Sørensen
Martin Kryspin Sørensen
Andreas KjaerAndreas Kjaer
Andreas Kjaer
BACKGROUND AND OBJECTIVES: Glioblastoma is an aggressive form of brain cancer for which surgery is the keystone in treatment before oncological treatment. Improving surgical resection without jeopardizing the outcome is eminent, and a fluorescent drug to aid surgical outcome is warranted. To evaluate the safety and the efficacy of a novel urokinase-type Plasminogen Activator Receptor-targeting near-infrared optical imaging agent, ICG-Glu-Glu-AE105 (FG001), in patients with malignant glioma (glioblastoma). METHODS: First-in-human phase I dose escalation and time elaboration study in 35 patients undergoing surgery for glioblastoma. The tumor-to-background ratio (TBR) was measured on near-infrared images as an objective measure of image contrast. Biopsies were taken during surgery from areas with and without fluorescence (FG001) and compared with pathology as reference. Efficacy was evaluated as sensitivity and specificity of FG001 to detect tumor tissue. The study was conducted with close safety monitoring. RESULTS: Administration of FG001 at a dose of 36 mg, 12 to 17 hours before surgery, resulted in optimal image contrast between tumor and normal brain tissue, with a mean TBR of 3.6. A high sensitivity (79%) and specificity (100%) for the detection of tumor tissue was found. Safety monitoring during the study identified only a few related adverse events, all of which were of mild grade. CONCLUSION: FG001 was found to be safe and well tolerated in the patients included in the study. The optimal dose of FG001 was selected on the basis of videos taken during the surgery and the measured TBR values. A dose of 36 mg administered 16 hours (mean) before the surgery showed the best contrast (TBR values) and optimal visualization of the tumor delineation. Histology demonstrated good sensitivity of FG001.

22 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
NONanna Overbeck
Nanna Overbeck
SASahar Ahangari
Sahar Ahangari
MCMaurizio Conti
Maurizio Conti
VPVladimir Panin
Vladimir Panin
AAAleena Azam
Aleena Azam
TAThomas Lund Andersen
Thomas Lund Andersen
Incorrect scatter scaling of positron emission tomography (PET) images can lead to halo artifacts, quantitative bias, or reconstruction failure. Tail-fitted scatter scaling (TFSS) possesses performance limitations in multiple cases. This study aims to investigate a novel method for scatter scaling: maximum-likelihood scatter scaling (MLSS) in scenarios where TFSS tends to induce artifacts or are observed to cause reconstruction abortion. [68Ga]Ga-RGD PET scans of nine patients were included in cohort 1 in the scope of investigating the reduction of halo artifacts relative to the scatter estimation method. PET scans of 30 patients administrated with [68Ga]Ga-uPAR were included in cohort 2, used for an evaluation of the robustness of MLSS in cases where TFSS-integrated reconstructions are observed to fail. A visual inspection of MLSS-corrected images scored higher than TFSS-corrected reconstructions of cohort 1. The quantitative investigation near the bladder showed a relative difference in tracer uptake of up to 94.7%. A reconstruction of scans included in cohort 2 resulted in failure in 23 cases when TFSS was used. The lesion uptake values of cohort 2 showed no significant difference. MLSS is suggested as an alternative scatter-scaling method relative to TFSS with the aim of reducing halo artifacts and a robust reconstruction process.