Xun Ma

Dr. Xun Ma

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
XQXiaodan Qiu
Xiaodan Qiu
YLYitong Liu
Yitong Liu
TZTing Zhao
Ting Zhao
LZLimin Zuo
Limin Zuo
XMXun Ma
Xun Ma
Guangzhi ShanGuangzhi Shan
Guangzhi Shan

28 November 2025 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
QJQingying Jia
Qingying Jia
XQXiaodan Qiu
Xiaodan Qiu
XZXuejia Zhao
Xuejia Zhao
HLHuiyi Liu
Huiyi Liu
YGYongsheng Gu
Yongsheng Gu
Guangzhi ShanGuangzhi Shan
Guangzhi Shan

27 February 2026 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
XMXun Ma
Xun Ma
LSLianlian Shan
Lianlian Shan
SZShuangpeng Zhu
Shuangpeng Zhu
ZZZihan Zhu
Zihan Zhu
SLShuyu Lu
Shuyu Lu
LYLihui Yin
Lihui Yin
Background/Objectives: Transmission Raman spectroscopy (TRS) is widely used for non-destructive quantification of solid dosage forms, yet most applications involve high-dose formulations (>5% w/w active pharmaceutical ingredient (API)). This study addresses the underexplored area of low-dose drug analysis by developing a TRS method for dimdazenil capsules containing only ~1.5% w/w API—a concentration rarely reported in the current TRS literature. Methods: A partial least squares (PLS) model was built using TRS spectra of dimdazenil capsules, with sample variability introduced via a design of experiments (DoE) approach. Model performance was validated against reference high-performance liquid chromatography (HPLC) data from independent samples and three commercial batches, incorporating specificity checks and greenness assessment via AGREEprep. Results: The TRS method achieved reliable variation assessment with acceptable accuracy, showing relative errors below 5.0% across all validation sets despite a minor systematic bias of ~−2.87%. Analysis required no sample preparation and took less than 150 s per capsule. Specificity was ensured by the unique 1628 cm−1 band of dimdazenil, with no interference from excipients confirmed by spectral examination and multivariate statistical methods. The method scored 0.86 on AGREEprep, highlighting its environmental superiority over HPLC. Conclusions: This work demonstrates that TRS can be reliably extended to low-dose solid dosage forms (~1.5% w/w), a concentration range rarely addressed in the existing TRS literature. This significantly broadens its applicability in pharmaceutical quality control and supports its potential integration into continuous manufacturing for challenging low-concentration products.