Xiaofei Hu

Dr. Xiaofei Hu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2018 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
QSQiaoqiao Shi
Qiaoqiao Shi
JHJie Huang
Jie Huang
YSYaning Sun
Yaning Sun
RDRuiguang Deng
Ruiguang Deng
MTMan Teng
Man Teng
GZGaiping Zhang
Gaiping Zhang

23 February 2015 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
YWYao Wang
Yao Wang
RDRuiguang Deng
Ruiguang Deng
GZGaiping Zhang
Gaiping Zhang
QLQingmei Li
Qingmei Li
JYJifei Yang
Jifei Yang
XHXiaofei Hu
Xiaofei Hu

1 October 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MHMei Hu
Mei Hu
YWYao Wang
Yao Wang
JYJifei Yang
Jifei Yang
YSYaning Sun
Yaning Sun
GXGuangxu Xing
Guangxu Xing
GZGaiping Zhang
Gaiping Zhang

27 November 2015 in Journal of the Science of Food and Agriculture
Verified
Journal Article
Closed access
PDF file
YSYaning Sun
Yaning Sun
GXGuangxu Xing
Guangxu Xing
JYJifei Yang
Jifei Yang
FWFangyu Wang
Fangyu Wang
RDRuiguang Deng
Ruiguang Deng
YZYong Zhang
Yong Zhang

5 March 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
YSYaning Sun
Yaning Sun
JYJifei Yang
Jifei Yang
SYSuzhen Yang
Suzhen Yang
QSQingbo Sang
Qingbo Sang
MTMan Teng
Man Teng
GZGaiping Zhang
Gaiping Zhang
A colloidal gold-based immunochromatographic strip with a competitive format has been developed for the rapid, simultaneous, semi-quantitative and quantitative detection of several aminoglycoside residues in milk, including gentamicin sulfate (GM), neomycin sulfate (NEO) and kanamycin sulfate (KN). Three monoclonal antibodies against the three corresponding aminoglycosides were conjugated to colloidal gold particles and applied to the conjugate pads of the strip. The competitors [GM-bovine serum albumin (GM-BSA), NEO-BSA and KN-BSA conjugates] of GM, NEO and KN were immobilized onto a nitrocellulose (NC) membrane at three detection zones, T1, T2, and T3, respectively. The minimal cut-off values of the strip were 10 ng mL−1 for GM, and 100 ng mL−1 for NEO and KN, which are lower than the maximum residue levels (MRLs) established for aminoglycosides. The IC50 values of the strip were 0.737 ng mL−1, 8.971 ng mL−1 and 11.110 ng mL−1 for GM, NEO and KN respectively. In conclusion, the immunochromatographic lateral flow strip could be used for rapid, simultaneous, semi-quantitative and quantitative detection of GM, NEO and KN residues in milk.

20 January 2017 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
YWYao Wang
Yao Wang
ZLZhaozhou Li
Zhaozhou Li
YPYafeng Pei
Yafeng Pei
QLQingmei Li
Qingmei Li
YSYaning Sun
Yaning Sun
XHXiaofei Hu
Xiaofei Hu