Jie Qin

Jie Qin


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JSJingwei Sheng
Jingwei Sheng
SWShuangai Wan
Shuangai Wan
YSYifan Sun
Yifan Sun
RDRongshe Dou
Rongshe Dou
YGYuhao Guo
Yuhao Guo
JGJia-Hong Gao
Jia-Hong Gao
In recent years, substantial progress has been made in developing a new generation of magnetoencephalography (MEG) with a spin-exchange relaxation free (SERF)-based atomic magnetometer (AM). An AM employs alkali atoms to detect weak magnetic fields. A compact AM array with high sensitivity is crucial to the design; however, most proposed compact AMs are potassium (K)- or rubidium (Rb)-based with single beam configurations. In the present study, a pump-probe two beam configuration with a Cesium (Cs)-based AM (Cs-AM) is introduced to detect human neuronal magnetic fields. The length of the vapor cell is 4 mm, which can fully satisfy the need of designing a compact sensor array. Compared with state-of-the-art compact AMs, our new Cs-AM has two advantages. First, it can be operated in a SERF regime, requiring much lower heating temperature, which benefits the sensor with a closer distance to scalp due to ease of thermal insulation and less electric heating noise interference. Second, the two-beam configuration in the design can achieve higher sensitivity. It is free of magnetic modulation, which is necessary in one-beam AMs; however, such modulation may cause other interference in multi-channel circumstances. In the frequency band between 10 Hz and 30 Hz, the noise level of the proposed Cs-AM is approximately 10 f T/Hz1/2, which is comparable with state-of-the-art K- or Rb-based compact AMs. The performance of the Cs-AM was verified by measuring human auditory evoked fields (AEFs) in reference to commercial superconducting quantum interference device (SQUID) channels. By using a Cs-AM, we observed a clear peak in AEFs around 100 ms (M100) with a much larger amplitude compared with that of a SQUID, and the temporal profiles of the two devices were in good agreement. The results indicate the possibility of using the compact Cs-AM for MEG recordings, and the current Cs-AM has the potential to be designed for multi-sensor arrays and gradiometers for future neuroscience studies.

22 January 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
YGYuhao Guo
Yuhao Guo
SWShuangai Wan
Shuangai Wan
XSXiaoguang Sun
Xiaoguang Sun
JQJie Qin
Jie Qin
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64  mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1  pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

17 June 2019 in Physical Review A
Verified
Journal Article
Closed access
PDF file
YCYue Chang
Yue Chang
YGYu-Hao Guo
Yu-Hao Guo
JQJie Qin
Jie Qin
Alkali-metal-vapor magnetometers, using coherent precession of polarized atomic spins for magnetic-field measurement, have become one of the most sensitive magnetic-field detectors. Their application areas range from practical uses such as NMR signal detection to fundamental physics research such as searches for permanent electric dipole moments. One of the main noise sources of atomic magnetometers comes from the light shift that depends on the frequency of the pump laser. In this work, we theoretically study the light shift, taking into account the relaxation due to the optical pumping and the collision between alkali-metal atoms and between alkali-metal atoms and the buffer gas. Starting from a full master equation containing both the ground and excited states, we adiabatically eliminate the excited states and obtain an effective master equation in the ground-state subspace that shows an intuitive picture and dramatically accelerates the numerical simulation. Solving this effective master equation, we find that in the light-narrowing regime, where the linewidth is reduced while the coherent precession signal is enhanced, the frequency dependence of the light shift is largely reduced, which agrees with experimental observations in cesium magnetometers. Since this effective master equation is general and is easily solved, it can be applied to an extensive parameter regime, and also to study other physical problems in alkali-metal-vapor magnetometers, such as heading errors.

18 December 2021 in arXiv
Verified
Preprint
Open access
PDF file
YCYue Chang
Yue Chang
YGYu-Hao Guo
Yu-Hao Guo
SWShuang-Ai Wan
Shuang-Ai Wan
JQJie Qin
Jie Qin
The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to the RF driving magnetic field. Thus, one can design the configuration of the magnetometer and make it work in the smaller-heading-error regime. To suppress the heading error, our studies suggest to sum up the output precession frequencies from atomic cells pumped by two lasers with opposite helicities and probed by lasers propagating in orthogonal directions (one parallel and another perpendicular to the RF field), instead of utilizing probe lasers propagating in the same directions. Due to the nuclear Zeeman effect, the average precession frequencies in the latter case can have a non-negligible angular dependence, while in the former case the nuclear-Zeeman-effect induced heading error can be largely compensated and the residue is within 1Hz. Furthermore, for practical use, we propose to simply utilize a small magnetic field parallel/antiparallel to the pump laser. By tuning the magnitude of this auxiliary field, the heading error can be flattened around different angles, which can improve the accuracy when the magnetometer works around a certain orientation angle.

18 June 2019 in arXiv
Verified
Preprint
Open access
PDF file
YCYue Chang
Yue Chang
YGYu-Hao Guo
Yu-Hao Guo
JQJie Qin
Jie Qin
Alkali-metal-vapor magnetometers, using coherent precession of polarized atomic spins for magnetic field measurement, have become one of the most sensitive magnetic field detectors. Their application areas range from practical uses such as detections of NMR signals to fundamental physics research such as searches for permanent electric dipole moments. One of the main noise sources of atomic magnetometers comes from the light shift that depends on the frequency of the pump laser. In this work, we theoretically study the light shift, taking into account the relaxation due to the optical pumping and the collision between alkali atoms and between alkali atoms and the buffer gas. Starting from a full master equation containing both the ground and excited states, we adiabatically eliminate the excited states and obtain an effective master equation in the ground-state subspace that shows an intuitive picture and dramatically accelerates the numerical simulation. Solving this effective master equation, we find that in the light-narrowing regime, where the line width is reduced while the coherent precession signal is enhanced, the frequency-dependence of the light shift is largely reduced, which agrees with experimental observations in cesium magnetometers. Since this effective master equation is general and is easily solved, it can be applied to an extensive parameter regime, and also to study other physical problems in alkali-metal-vapor magnetometers, such as heading errors.