Chu-Yu Lee

Dr. Chu-Yu Lee


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MPMichael Petronek
Michael Petronek
NTNahom Teferi
Nahom Teferi
CLChu-Yu Lee
Chu-Yu Lee
VMVincent A. Magnotta
Vincent A. Magnotta
BABryan Allen
Bryan Allen
Recently, the FDA-approved iron oxide nanoparticle, ferumoxytol, has been found to enhance the efficacy of pharmacological ascorbate (AscH−) in treating glioblastoma, as AscH− reduces the Fe3+ sites in the nanoparticle core. Given the iron oxidation state specificity of T2* relaxation mapping, this study aims to investigate the ability of T2* relaxation to monitor the reduction of ferumoxytol by AscH− with respect to its in vitro therapeutic enhancement. This study employed an in vitro glioblastoma MRI model system to investigate the chemical interaction of ferumoxytol with T2* mapping. Lipofectamine was utilized to facilitate ferumoxytol internalization and assess intracellular versus extracellular chemistry. In vitro T2* mapping successfully detected an AscH−-mediated reduction of ferumoxytol (25.6 ms versus 2.8 ms for FMX alone). The T2* relaxation technique identified the release of Fe2+ from ferumoxytol by AscH− in glioblastoma cells. However, the high iron content of ferumoxytol limited T2* ability to differentiate between the external and internal reduction of ferumoxytol by AscH− (ΔT2* = +839% for external FMX and +1112% for internal FMX reduction). Notably, the internalization of ferumoxytol significantly enhances its ability to promote AscH− toxicity (dose enhancement ratio for extracellular FMX = 1.16 versus 1.54 for intracellular FMX). These data provide valuable insights into the MR-based nanotheranostic application of ferumoxytol and AscH− therapy for glioblastoma management. Future developmental efforts, such as FMX surface modifications, may be warranted to enhance this approach further.

1 January 2022 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
CLChu-Yu Lee
Chu-Yu Lee
KBKevin M. Bennett
Kevin M. Bennett
JDJosef P. Debbins
Josef P. Debbins
ICIn-Young Choi
In-Young Choi
PLPhil Lee
Phil Lee

27 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JXJia Xu
Jia Xu
MVMichael Vaeggemose
Michael Vaeggemose
RSRolf F Schulte
Rolf F Schulte
BYBaolian Yang
Baolian Yang
CLChu-Yu Lee
Chu-Yu Lee
VMVincent A. Magnotta
Vincent A. Magnotta
Background/Objectives: Magnetic resonance spectroscopy (MRS) is a valuable tool for studying metabolic processes in vivo. While numerous quantification methods exist, the advanced method for accurate, robust, and efficient spectral fitting (AMARES) is among the most used. This study introduces pyAMARES, an open-source Python implementation of AMARES, addressing the need for a flexible, user-friendly, and versatile MRS quantification tool within the Python ecosystem. Methods: PyAMARES was developed as a Python library, implementing the AMARES algorithm with additional features such as multiprocessing capabilities and customizable objective functions. The software was validated against established AMARES implementations (OXSA and jMRUI) using both simulated and in vivo MRS data. Monte Carlo simulations were conducted to assess robustness and accuracy across various signal-to-noise ratios and parameter perturbations. Results: PyAMARES utilizes spreadsheet-based prior knowledge and fitting parameter settings, enhancing flexibility and ease of use. It demonstrated comparable performance to existing software in terms of accuracy, precision, and computational efficiency. In addition to conventional AMARES fitting, pyAMARES supports fitting without prior knowledge, frequency-selective AMARES, and metabolite residual removal from mobile macromolecule (MM) spectra. Utilizing multiple CPU cores significantly enhances the performance of pyAMARES. Conclusions: PyAMARES offers a robust, flexible, and user-friendly solution for MRS quantification within the Python ecosystem. Its open-source nature, comprehensive documentation, and integration with popular data science tools enhance reproducibility and collaboration in MRS research. PyAMARES bridges the gap between traditional MRS fitting methods and modern machine learning frameworks, potentially accelerating advancements in metabolic studies and clinical applications.

11 July 2024 in Tomography
Verified
Journal Article
Open access
PDF file
CLChu-Yu Lee
Chu-Yu Lee
DTDaniel R. Thedens
Daniel R. Thedens
OLOlivia Lullmann
Olivia Lullmann
ESEmily Steinbach
Emily Steinbach
MTMichelle Rossa Tamplin
Michelle Rossa Tamplin
VMVincent A. Magnotta
Vincent A. Magnotta
The MR transverse relaxation rate, R2*, has been widely used to detect iron and myelin content in tissue. However, it is also sensitive to macroscopic B0 inhomogeneities. One approach to correct for the B0 effect is to fit gradient-echo signals with the three-parameter model, a sinc function-weighted monoexponential decay. However, such three-parameter models are subject to increased noise sensitivity. To address this issue, this study presents a two-stage fitting procedure based on the three-parameter model to mitigate the B0 effect and reduce the noise sensitivity of R2* measurement in the mouse brain at 7T. MRI scans were performed on eight healthy mice. The gradient-echo signals were fitted with the two-stage fitting procedure to generate R2corr_t*. The signals were also fitted with the monoexponential and three-parameter models to generate R2nocorr* and R2corr*, respectively. Regions of interest (ROIs), including the corpus callosum, internal capsule, somatosensory cortex, caudo-putamen, thalamus, and lateral ventricle, were selected to evaluate the within-ROI mean and standard deviation (SD) of the R2* measurements. The results showed that the Akaike information criterion of the monoexponential model was significantly reduced by using the three-parameter model in the selected ROIs (p = 0.0039–0.0078). However, the within-ROI SD of R2corr* using the three-parameter model was significantly higher than that of the R2nocorr* in the internal capsule, caudo-putamen, and thalamus regions (p = 0.0039), a consequence partially due to the increased noise sensitivity of the three-parameter model. With the two-stage fitting procedure, the within-ROI SD of R2corr* was significantly reduced by 7.7–30.2% in all ROIs, except for the somatosensory cortex region with a fast in-plane variation of the B0 gradient field (p = 0.0039–0.0078). These results support the utilization of the two-stage fitting procedure to mitigate the B0 effect and reduce noise sensitivity for R2* measurement in the mouse brain.