SungWoo YOUN

Dr. SungWoo YOUN

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
OKOhjoon Kwon
Ohjoon Kwon
DLDoyu Lee
Doyu Lee
WCWoohyun Chung
Woohyun Chung
DADanho Ahn
Danho Ahn
HBHeeSu Byun
HeeSu Byun
YSYannis K. Semertzidis
Yannis K. Semertzidis
The Center for Axion and Precision Physics Research at the Institute for Basic Science is searching for axion dark matter using ultralow temperature microwave resonators. We report the exclusion of the axion mass range 10.7126–10.7186  μeV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16–11.37  μeV with about 9 times larger coupling at 90% confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

25 November 2020 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JJJunu Jeong
Junu Jeong
SYSungWoo YOUN
SungWoo YOUN
SBSungjae Bae
Sungjae Bae
JKJihngeun Kim
Jihngeun Kim
TSTaehyeon Seong
Taehyeon Seong
YSYannis K. Semertzidis
Yannis K. Semertzidis
We present the first results of a search for invisible axion dark matter using a multiple-cell cavity haloscope. This cavity concept was proposed to provide a highly efficient approach to high-mass regions compared to the conventional multiple-cavity design, with larger detection volume, simpler detector setup, and a unique phase-matching mechanism. Searches with a double-cell cavity superseded previous reports for the axion-photon coupling over the mass range between 13.0 and 13.9  μeV. This result not only demonstrates the novelty of the cavity concept for high-mass axion searches, but also suggests it can make considerable contributions to the next-generation experiments.

19 October 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
CAC. M. Adair
C. M. Adair
KAK. Altenmüller
K. Altenmüller
VAV. Anastassopoulos
V. Anastassopoulos
SCS. Arguedas Cuendis
S. Arguedas Cuendis
JBJ. Baier
J. Baier
Konstantin ZioutasKonstantin Zioutas
Konstantin Zioutas
The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 μeV to 22.47 μeV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/ min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to gaγγ = 8 × 10−14 GeV−1 at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.

25 February 2022 in Science Advances
Verified
Journal Article
Open access
YSYannis K. Semertzidis
Yannis K. Semertzidis
SYSungWoo YOUN
SungWoo YOUN
The axion is a highly motivated elementary particle that could address two fundamental questions in physics—the strong charge-parity (CP) problem and the dark matter mystery. Experimental searches for this hypothetical particle started reaching theoretically interesting sensitivity levels, particularly in the micro–electron volt (gigahertz) region. They rely on microwave resonators in strong magnetic fields with signals read out by quantum noise limited amplifiers. Concurrently, there have been intensive experimental efforts to widen the search range by devising various techniques and to enhance sensitivities by implementing advanced technologies. These orthogonal approaches will enable us to explore most of the parameter space for axions and axion-like particles within the next decades, with the 1- to 25-gigahertz frequency range to be conquered well within the first decade. We review the experimental aspects of axion physics and discuss the past, present, and future of the direct search programs.

1 February 2018 in Physics Letters B
Verified
Journal Article
Open access
JJJunu Jeong
Junu Jeong
SYSungWoo YOUN
SungWoo YOUN
SASaebyeok Ahn
Saebyeok Ahn
JKJihn E. Kim
Jihn E. Kim
YSYannis K. Semertzidis
Yannis K. Semertzidis
In cavity-based axion dark matter search experiments exploring high mass regions, multiple-cavity design is considered to increase the detection volume within a given magnet bore. We introduce a new idea, referred to as multiple-cell cavity, which provides various benefits including a larger detection volume, simpler experimental setup, and easier phase-matching mechanism. We present the characteristics of this concept and demonstrate the experimental feasibility with an example of a double-cell cavity.Comment: 8 pages, 11 figure

12 August 2024 in Physical Review X
Verified
Journal Article
Open access
PDF file
SASaebyeok Ahn
Saebyeok Ahn
JKJinMyeong Kim
JinMyeong Kim
BIBoris I. Ivanov
Boris I. Ivanov
OKOhjoon Kwon
Ohjoon Kwon
HBHeeSu Byun
HeeSu Byun
YSYannis K. Semertzidis
Yannis K. Semertzidis
We report an extensive high-sensitivity search for axion dark matter above 1 GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025 GHz (4.24  μeV) to 1.185 GHz (4.91  μeV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12 T magnet with an aperture of 320 mm made of Nb3Sn and NbTi superconductors surrounding a 37 l ultralight-weight copper cavity is expected to convert Dine-Fischler-Srednicki-Zhitnitsky axions into approximately 102 microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40 mK, combined with quantum-noise-limited readout electronics, achieved a total system noise of about 200 mK or below, which corresponds to a background of roughly 4×103 photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion-photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly sensitive searches for axion dark matter above 1 GHz.