Elizabeth B. Maghirang

Mrs. Elizabeth B. Maghirang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Fatima Rodriguez MacadaegFatima Rodriguez Macadaeg
Fatima Rodriguez Macadaeg
PAPaul R Armstrong
Paul R Armstrong
EMElizabeth B. Maghirang
Elizabeth B. Maghirang
ESErin Scully
Erin Scully
DBDaniel L. Brabec
Daniel L. Brabec
DSDelfin C. Suministrado
Delfin C. Suministrado
A recent study showed the potential of the DA Perten 7200 NIR Spectrometer in detecting chlorpyrifos-methyl pesticide residue in rough, brown, and milled rice. However, this instrument is still lab-based and generally suited for point-of-sale testing. To provide a field-deployable version of this technique, an existing light emitting diode (LED)-based instrument that provides discrete NIR wavelength illumination and reflectance spectra over the range of 850–1550 nm was tested. Spectra were collected from rough, brown, and milled rice at different pesticide concentrations and analyzed for quantitative and qualitative measurement using partial least squares regression (PLS) and discriminant analysis (DA). Simulations for two LED-based instruments were also evaluated using corresponding segments of spectra from the DA7200 to represent LED illumination. For the simulation of the existing LED-based instrument (LEDPrototype1) fitted with 850, 910, 940, 970, 1070, 1200, 1300, 1450, and 1550 nm LED wavelengths, resulting R2 ranged from 0.52 to 0.71, and the correct classification was 70.4% to 100%. The simulation of a second LED instrument (LEDPrototype2) fitted with 980, 1050, 1200, 1300, 1450, 1550, 1600, and 1650 nm LED wavelengths showed R2 of 0.59 to 0.82 and correct classifications of 66% to 100%. These LED wavelengths were selected based on the significant wavelength regions from the PLS regression coefficients of DA7200 and the commercial availability of LED wavelengths. Results showed that it is possible to use a multi-spectral LED-based instrument to detect varying levels of chlorpyrifos-methyl pesticide residue in rough, brown, and milled rice.

3 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Fatima Rodriguez MacadaegFatima Rodriguez Macadaeg
Fatima Rodriguez Macadaeg
PAPaul R Armstrong
Paul R Armstrong
EMElizabeth B. Maghirang
Elizabeth B. Maghirang
ESErin Scully
Erin Scully
DBDaniel L. Brabec
Daniel L. Brabec
DSDelfin C. Suministrado
Delfin C. Suministrado
A recent study showed the potential of DA Perten 7200 NIR Spectrometer in detecting chlorpyrifos-methyl pesticide residue in rough, brown, and milled rice. However, this instrument is still lab-based and generally suited for point-of-sale testing in many countries. To provide a field deployable version of this technique, an existing light emitting diode (LED)-based instrument which provide discrete NIR wavelength illumination and reflectance spectra over the range of 850-1550 nm was tested. Spectra were collected from rough, brown, and milled rice at different pesticide concentrations and analysed for quantitative and qualitative measurement using partial least squares regression (PLS) and discriminant analysis (DA). Simulations for LED-based instruments were also evaluated using segments of spectra from the DA7200 to represent LED illumination. For the simulation of the existing LED-based instrument (LEDPrototype1) using their wavelengths range yielded 70.4% to 100% correct classification. Simulation of a second LED instrument, LEDPrototype2, with spectral segments selected based on significant wavelength regions from PLS regressions coefficients obtained from the DA7200 showed improved performance with R2 of 0.59 to 0.82 and correct classifications of 71.3 to 100%. An actual LED based instrument with this capability could provide a quick screening tool to determine if MRLs are exceeded.