Qing Yuan

Dr. Qing Yuan


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Radiology
Verified
Journal Article
Closed access
DHDiego Hernando
Diego Hernando
RZRuiyang Zhao
Ruiyang Zhao
QYQing Yuan
Qing Yuan
MGMounes Aliyari Ghasabeh
Mounes Aliyari Ghasabeh
SRStefan Ruschke
Stefan Ruschke
SRScott B. Reeder
Scott B. Reeder
MRI-based R2* mapping enabled reproducible quantification of liver iron overload across four centers, three vendors, and three field strengths (1.5 T, 2.89 T, and 3.0 T). Background MRI is a standard of care tool to measure liver iron concentration (LIC). Compared with regulatory-approved R2 MRI, R2* MRI has superior speed and is available in most MRI scanners; howe...

3 August 2017 in JCI Insight
Verified
Journal Article
Open access
PDF file
YZYue Zhang
Yue Zhang
DUDurga Udayakumar
Durga Udayakumar
LCLing Cai
Ling Cai
ZHZeping Hu
Zeping Hu
PKPayal Kapur
Payal Kapur
IPIvan Pedrosa
Ivan Pedrosa
BACKGROUND. Dysregulated lipid and glucose metabolism in clear cell renal cell carcinoma (ccRCC) has been implicated in disease progression, and whole tumor tissue–based assessment of these changes is challenged by the tumor heterogeneity. We studied a noninvasive quantitative MRI method that predicts metabolic alterations in the whole tumor. METHODS. We applied Dixon-based MRI for in vivo quantification of lipid accumulation (fat fraction [FF]) in targeted regions of interest of 45 primary ccRCCs and correlated these MRI measures to mass spectrometry–based lipidomics and metabolomics of anatomically colocalized tissue samples isolated from the same tumor after surgery. RESULTS. In vivo tumor FF showed statistically significant ( P < 0.0001) positive correlation with histologic fat content (Spearman correlation coefficient, ρ = 0.79), spectrometric triglycerides (ρ = 0.56) and cholesterol (ρ = 0.47); it showed negative correlation with free fatty acids (ρ = –0.44) and phospholipids (ρ = –0.65). We observed both inter- and intratumoral heterogeneity in lipid accumulation within the same tumor grade, whereas most aggressive tumors (International Society of Urological Pathology [ISUP] grade 4) exhibited reduced lipid accumulation. Cellular metabolites in tumors were altered compared with adjacent renal parenchyma. CONCLUSION. Our results support the use of noninvasive quantitative Dixon-based MRI as a biomarker of reprogrammed lipid metabolism in ccRCC, which may serve as a predictor of tumor aggressiveness before surgical intervention. FUNDING. NIH R01CA154475 (YZ, MF, PK, IP), NIH P50CA196516 (IP, JB, RJD, JAC, PK), Welch Foundation I-1832 (JY), and NIH P01HL020948 (JGM).

24 August 2017 in Diagnostics
Verified
Journal Article
Open access
PDF file
HZHeling Zhou
Heling Zhou
RHRami Hallac
Rami Hallac
QYQing Yuan
Qing Yuan
YDYao Ding
Yao Ding
ZZZhongwei Zhang
Zhongwei Zhang
Ralph MasonRalph Mason
Ralph Mason
Hypoxia is associated with prostate tumor aggressiveness, local recurrence, and biochemical failure. Magnetic resonance imaging (MRI) offers insight into tumor pathophysiology and recent reports have related transverse relaxation rate (R2*) and longitudinal relaxation rate (R1) measurements to tumor hypoxia. We have investigated the inclusion of oxygen-enhanced MRI for multi-parametric evaluation of tumor malignancy. Multi-parametric MRI sequences at 3 Tesla were evaluated in 10 patients to investigate hypoxia in prostate cancer prior to radical prostatectomy. Blood oxygen level dependent (BOLD), tissue oxygen level dependent (TOLD), dynamic contrast enhanced (DCE), and diffusion weighted imaging MRI were intercorrelated and compared with the Gleason score. The apparent diffusion coefficient (ADC) was significantly lower in tumor than normal prostate. Baseline R2* (BOLD-contrast) was significantly higher in tumor than normal prostate. Upon the oxygen breathing challenge, R2* decreased significantly in the tumor tissue, suggesting improved vascular oxygenation, however changes in R1 were minimal. R2* of contralateral normal prostate decreased in most cases upon oxygen challenge, although the differences were not significant. Moderate correlation was found between ADC and Gleason score. ADC and R2* were correlated and trends were found between Gleason score and R2*, as well as maximum-intensity-projection and area-under-the-curve calculated from DCE. Tumor ADC and R2* have been associated with tumor hypoxia, and thus the correlations are of particular interest. A multi-parametric approach including oxygen-enhanced MRI is feasible and promises further insights into the pathophysiological information of tumor microenvironment.

25 April 2024 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
GSGregory Simchick
Gregory Simchick
RZRuiyang Zhao
Ruiyang Zhao
QYQing Yuan
Qing Yuan
MGMounes Aliyari Ghasabeh
Mounes Aliyari Ghasabeh
SRStefan Ruschke
Stefan Ruschke
DHDiego Hernando
Diego Hernando
Background: Recent multicenter, multivendor MRI‐based R2* vs. liver iron concentration (LIC) calibrations (i.e., MCMV calibrations) may facilitate broad clinical dissemination of R2*‐based LIC quantification. However, these calibrations are based on a centralized offline R2* reconstruction, and their applicability with vendor‐provided R2* maps is unclear.Purpose: To determine R2* ranges of agreement between the centralized and three MRI vendors' R2* reconstructions.Study Type: Prospective.Subjects: Two hundred and seven subjects (mean age 37.6 ± 19.6 years; 117 male) with known or suspected iron overload from four academic medical centers.Field Strength/Sequence: Standardized multiecho spoiled gradient echo sequence at 1.5 T and 3.0 T for R2* mapping and a multiple spin‐echo sequence at 1.5 T for LIC quantification. MRI vendors: GE Healthcare, Philips Healthcare, and Siemens Healthineers.Assessment: R2* maps were generated using both the centralized and vendor reconstructions, and ranges of agreement were determined. R2*‐LIC linear calibrations were determined for each site, field strength, and reconstruction and compared with the MCMV calibrations.Statistical Tests: Bland–Altman analysis to determine ranges of agreement. Linear regression, analysis of covariance F tests, and Tukey's multiple comparison testing to assess reproducibility of calibrations across sites and vendors. A P value <0.05 was considered significant.Results: The upper limits of R2* ranges of agreement were approximately 500, 375, and 330 s−1 for GE, Philips, and Siemens reconstructions, respectively, at 1.5 T and approximately 700 and 800 s−1 for GE and Philips, respectively, at 3.0 T. Within the R2* ranges of agreement, vendor R2*‐LIC calibrations demonstrated high reproducibility (no significant differences between slopes or intercepts; P ≥ 0.06) and agreed with the MCMV calibrations (overlapping 95% confidence intervals).Data Conclusion: Based on the determined upper limits, R2* measurements obtained from vendor‐provided R2* maps may be reliably and practically used to quantify LIC less than approximately 8–13 mg/g using the MCMV calibrations and similar acquisition parameters as this study.Evidence Level: 1Technical Efficacy: Stage 3

1 March 2008 in Asian Journal of Andrology
Verified
Journal Article
Open access
SCShao-Feng Cao
Shao-Feng Cao
LDLi Ding
Li Ding
QYQing Yuan
Qing Yuan
XGXin Guan
Xin Guan
XCXu Chen
Xu Chen
AJA publishes new findings in basic and clinical (including modern, traditional and epidemiological) research on Andrology.

31 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JGJacqueline Gallet
Jacqueline Gallet
ESElisabetta Sassaroli
Elisabetta Sassaroli
QYQing Yuan
Qing Yuan
AAAreej Aljabal
Areej Aljabal
MPMi-Ae Park
Mi-Ae Park
Ultrasound elastography has been available on most modern systems; however, the implementation of quality processes tends to be ad hoc. It is essential for a medical physicist to benchmark elastography measurements on each system and track them over time, especially after major software upgrades or repairs. This study aims to establish baseline data using phantoms and monitor them for quality assurance in elastography. In this paper, we utilized two phantoms: a set of cylinders, each with a composite material with varying Young’s moduli, and an anthropomorphic abdominal phantom containing a liver modeled to represent early-stage fibrosis. These phantoms were imaged using three ultrasound manufacturers’ elastography functions with either point or 2D elastography. The abdominal phantom was also imaged using magnetic resonance elastography (MRE) as it is recognized as the non-invasive gold standard for staging liver fibrosis. The scaling factor was determined based on the data acquired using MR and US elastography from the same vendor. The ultrasound elastography measurements showed inconsistency between different manufacturers, but within the same manufacturer, the measurements showed high repeatability. In conclusion, we have established baseline data for quality assurance procedures and specified the criteria for the acceptable range in liver fibrosis phantoms during routine testing.