Sangyun Cho

Prof. Dr. Sangyun Cho


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
WJWoo Jae Jeon
Woo Jae Jeon
SCSangyun Cho
Sangyun Cho
SBSeong Jin Baek
Seong Jin Baek
KKKyoung Hun Kim
Kyoung Hun Kim
The relatively recently developed I-gel (Intersurgical Ltd., Workingham, England) is a supraglottic airway device designed for single-use that, unlike conventional LMAs, does not require an inflatable cuff. In addition, the I-gel, much like the Proseal LMA (PLMA), has a gastric drainage tube associated with an upper tube for decompression of the stomach, thereby avoiding acid reflux and decreasing the risk of pulmonary absorption. The purpose of this study was to compare PLMA and I-gel devices in patients undergoing gynecological laparoscopy based on sealing pressure before and during pneumoperitoneum, insertion time, and gas exchange. Following Institutional Review Board approval and written informed consent, 30 adult patients were randomly allocated to one of two groups (the PLMA or I-gel group). In each case, insertion time and number of attempts were recorded. After successful insertion, airway leak pressure was measured. Successful insertion and mechanical ventilation with both supraglottic airway devices was achieved on the first attempt in all 30 patients, and there were no significant differences with respect to insertion time. Likewise, leak pressure did not vary significantly either between or within groups after CO(2) insufflation. In addition, differences between leak volume and leak fraction between groups were not significant. The results of our study indicate that the I-gel is a reasonable alternative to the PLMA for controlled ventilation during laparoscopic gynecologic surgery.

1 October 2019 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
JRJae Hyung Ryu
Jae Hyung Ryu
JSJae Hang Shim
Jae Hang Shim
JYJong Hoon Yeom
Jong Hoon Yeom
WSWoon Geon Shin
Woon Geon Shin
SCSangyun Cho
Sangyun Cho
WJWoo Jae Jeon
Woo Jae Jeon
Background: Ultrasound-guided greater occipital nerve (GON) block has been frequently used to treat various types of headaches, and botulinum toxin has recently begun to be used in patients with headache. Our study presents the longterm effect of botulinum toxin on GON block using ultrasound in patients with chronic headache in occipital area. Methods: Patients with occipital headache were divided into two groups (bupivacaine: BUP group [n = 27], botulinum toxin: BTX group [n = 27]), and ultrasound-guided GON block was performed at the C2 level. GON was detected with ultrasound and distance from GON to midline, from the skin surface to GON, and size of GON were measured in both groups. Visual analogue scale (VAS) scores and Likert scale were assessed at pretreatment and at 1, 4, 8, and 24 weeks after treatment in both groups. Results: The distance from GON to midline was 18.9 ± 4.4 mm (right) and 17.3 ± 3.8 mm (left). The depth from the skin was 12.9 ± 1.5 mm (right) and 13.4 ± 1.6 mm (left). GON size was 3.1 mm on both sides. The VAS score and patient satisfaction score (Likert scale) in 4, 8, and 24 weeks after injection were superior for the BTX than the BUP group. Conclusions: Ultrasound-guided GON block using BTX is effective in reducing short-term and long-term pain in patients with chronic headache in the occipital area.

1 January 2011 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
WJWoo Jae Jeon
Woo Jae Jeon
SCSangyun Cho
Sangyun Cho
MBMi Rang Bang
Mi Rang Bang
SKSo-Young Ko
So-Young Ko
Several publications have reported the successful, safe use of Laryngeal Mask Airway (LMA)-Classic devices in patients undergoing laparoscopic surgery. However, there have been no studies that have examined the application of volume-controlled ventilation (VCV) or pressure-controlled ventilation (PCV) using a LMA during gynecological laparoscopy. The aim of this study is to compare how the VCV and PCV modes and using a LMA affect the pulmonary mechanics, the gas exchange and the cardiovascular responses in patients who are undergoing gynecological laparoscopy. Sixty female patients were randomly allocated to one of two groups, (the VCV or PCV groups). In the VCV group, baseline ventilation of the lung was performed with volume-controlled ventilation and a tidal volume of 10 ml/kg ideal body weight (IBW). In the PCV group, baseline ventilation of the lung using pressure-controlled ventilation was initiated with a peak airway pressure that provided a tidal volume of 10 ml/kg IBW and an upper limit of 35 cmH(2)O. The end-tidal CO(2), the peak airway pressures (P(peak)), the compliance, the airway resistance and the arterial oxygen saturation were recorded at T1: 5 minutes after insertion of the laryngeal airway, and at T2 and T3: 5 and 15 minutes, respectively, after CO(2) insufflation. The P(peak) at 5 minutes and 15 minutes after CO(2) insufflation were significantly increased compared to the baseline values in both groups. Also, at 5 minutes and 15 minutes after CO(2) insufflation, there were significant differences of the P(peak) between the two groups. The compliance decreased in both groups after creating the pneumopertoneim (P < 0.05). Our results demonstrate that PCV may be an effective method of ventilation during gynecological laparoscopy, and it ensures oxygenation while minimizing the increases of the peak airway pressure after CO(2) insufflation.

1 January 2011 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
WJWoo Jae Jeon
Woo Jae Jeon
KKKyoung Hun Kim
Kyoung Hun Kim
JYJong Hoon Yeom
Jong Hoon Yeom
MBMi Rang Bang
Mi Rang Bang
JHJin-Bum Hong
Jin-Bum Hong
SCSangyun Cho
Sangyun Cho
The Glidescope® videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computer-generated numbers. Tracheal intubation was attempted by an anesthesiologist with extensive experience using these two devices. The operator recorded ease of visualization of glottic structures based on the classification described by Cormack and Lehane. Number of failures, number of attempts and their duration, total intubation time, and events during the whole procedure were recorded. The duration of one attempt was defined as the time elapsed between picking up the endotracheal tube and verification of tracheal intubation with visualization of three expiratory carbon dioxide waveforms. TTI was defined as the sum of the duration of all intubation attempts (as many as three), excluding preoxygenation procedures. TTI was significantly shorter for the Glidescope® compared to the McGrath® laryngoscope (40.5 vs. 53.3 s, respectively, P < 0.05). However, glottic views obtained at intubation were similar between the two groups. Number of intubation attempts was not significantly different between the two groups (1.03 ± 0.19 vs 1.10 ± 0.32, respectively) (mean ± SD). Study results demonstrated that the Glidescope reduced total intubation time in comparison with the McGrath, in terms of TTI in patients with normal airways.

17 April 2013 in Anaesthesia
Verified
Journal Article
Open access
PDF file
WJW. J. Jeon
W. J. Jeon
JSJ. H. Shim
J. H. Shim
SCSangyun Cho
Sangyun Cho
SBS. J. Baek
S. J. Baek
Summary: The GlideScope ® videolaryngoscope is widely used in the management of the difficult airway. However, passing the tracheal tube through the vocal cords can be awkward, and the use of a stylet to guide insertion is recommended. This randomised controlled trial evaluated a forceps‐guided tube exchanger as an alternative to the stylet to aid intubation with the GlideScope in patients undergoing anaesthesia, with a simulated difficult airway created by the application of a semi‐rigid cervical collar. Data were analysed from 178 patients randomly assigned to undergo intubation using either the stylet (n = 88) or a forceps‐guided tube exchanger (n = 90). All intubations were completed successfully, with first attempt rates of 93.2% using the stylet and 94.4% using the exchanger (p = 0.597). The mean ( SD ) intubation time was 67.8 (28.7) s in the stylet group and 66.1 (15.5) s in the forceps‐guided tube exchanger group (p = 0.11). The frequency of sore throat 1 h after extubation was 34.1% in the stylet group and 2.2% in the tube exchanger group (p < 0.001); 24 h after extubation the corresponding figures were 40.0% and 11.1% (p < 0.001). Using a forceps‐guided tube exchanger may offer an advantage over a stylet in guiding tracheal intubation when the GlideScope is used.

26 September 2017 in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
Verified
Journal Article
Open access
PDF file
JYJong H. Yeom
Jong H. Yeom
MOMi K. Oh
Mi K. Oh
WSWoo J. Shin
Woo J. Shin
DADae W. Ahn
Dae W. Ahn
WJWoo J. Jeon
Woo J. Jeon
SCSangyun Cho
Sangyun Cho
The GlideScope® video laryngoscope (GVL) is widely used for nasotracheal intubation in dental and facial plastic surgery. The angle of the Magill forceps is different from that of the GVL blade, which suggests that the Magill forceps are not the ideal forceps for use with the GVL. The purpose of this study was to compare the effectiveness of the Magill forceps vs vascular forceps for nasotracheal intubation using the GVL.