Róża Wajer

Mrs. Róża Wajer

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
RWRóża Wajer
Róża Wajer
AWAdrian Wajer
Adrian Wajer
VKVeronica Kiian
Veronica Kiian
AKAnna Kloska
Anna Kloska
ZSZbigniew Serafin
Zbigniew Serafin
Background/Objectives: Periapical lesions (PLs) are frequently detected in dental radiology. Accurate diagnosis of these lesions is essential for proper treatment planning. Imaging techniques such as orthopantomogram (OPG) and cone-beam CT (CBCT) imaging are used to identify PLs. The aim of this study was to assess the diagnostic accuracy of artificial intelligence (AI) software Diagnocat for PL detection in OPG and CBCT images. Methods: The study included 49 patients, totaling 1223 teeth. Both OPG and CBCT images were analyzed by AI software and by three experienced clinicians. All the images were obtained in one patient cohort, and findings were compared to the consensus of human readers using CBCT. The AI’s diagnostic accuracy was compared to a reference method, calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and F1 score. Results: The AI’s sensitivity for OPG images was 33.33% with an F1 score of 32.73%. For CBCT images, the AI’s sensitivity was 77.78% with an F1 score of 84.00%. The AI’s specificity was over 98% for both OPG and CBCT images. Conclusions: The AI demonstrated high sensitivity and high specificity in detecting PLs in CBCT images but lower sensitivity in OPG images.

Verified
Journal Article
Open access
PDF file
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
Julien IssaJulien Issa
Julien Issa
RWRóża Wajer
Róża Wajer
AWAdrian Wajer
Adrian Wajer
ZSZbigniew Serafin
Zbigniew Serafin
Background/Objectives: The aim of this study was to assess the diagnostic accuracy of the AI-driven platform Diagnocat for evaluating endodontic treatment outcomes using cone beam computed tomography (CBCT) images. Methods: A total of 55 consecutive patients (15 males and 40 females, aged 12–70 years) referred for CBCT imaging were included. CBCT images were analyzed using Diagnocat’s AI platform, which assessed parameters such as the probability of filling, adequate obturation, adequate density, overfilling, voids in filling, short filling, and root canal number. The images were also evaluated by two experienced human readers. Diagnostic accuracy metrics (accuracy, precision, recall, and F1 score) were assessed and compared to the readers’ consensus, which served as the reference standard. Results: The AI platform demonstrated high diagnostic accuracy for most parameters, with perfect scores for the probability of filling (accuracy, precision, recall, F1 = 100%). Adequate obturation showed moderate performance (accuracy = 84.1%, precision = 66.7%, recall = 92.3%, and F1 = 77.4%). Adequate density (accuracy = 95.5%, precision, recall, and F1 = 97.2%), overfilling (accuracy = 95.5%, precision = 86.7%, recall = 100%, and F1 = 92.9%), and short fillings (accuracy = 95.5%, precision = 100%, recall = 86.7%, and F1 = 92.9%) also exhibited strong performance. The performance of AI for voids in filling detection (accuracy = 88.6%, precision = 88.9%, recall = 66.7%, and F1 = 76.2%) highlighted areas for improvement. Conclusions: The AI platform Diagnocat showed high diagnostic accuracy in evaluating endodontic treatment outcomes using CBCT images, indicating its potential as a valuable tool in dental radiology.

17 June 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
RWRóża Wajer
Róża Wajer
AWAdrian Wajer
Adrian Wajer
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
JWJustyna Wilamowska
Justyna Wilamowska
ZSZbigniew Serafin
Zbigniew Serafin
Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Methods: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with the ClariCT.AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. Results: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p < 0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p < 0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. Conclusions: AI-based noise reduction using ClariCT.AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.

Verified
Journal Article
Open access
PDF file
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
RWRóża Wajer
Róża Wajer
AWAdrian Wajer
Adrian Wajer
KKKarol Kalka
Karol Kalka
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
ZSZbigniew Serafin
Zbigniew Serafin
Background/Objectives: The purpose of this preliminary study was to evaluate the diagnostic performance of an AI-driven platform, Diagnocat (Diagnocat Ltd., San Francisco, CA, USA), for assessing endodontic treatment outcomes using panoramic radiographs (PANs). Materials and Methods: The study included 55 PAN images of 55 patients (15 males and 40 females, aged 12–70) who underwent imaging at a private dental center. All images were acquired using a Hyperion X9 PRO digital cephalometer and were evaluated using Diagnocat, a cloud-based AI platform. The AI system assessed the following endodontic treatment features: filling probability, obturation adequacy, density, overfilling, voids in filling, and short filling. Two human observers independently evaluated the images, and their consensus served as the reference standard. The diagnostic accuracy metrics were calculated. Results: The AI system demonstrated high accuracy (90.72%) and a strong F1 score (95.12%) in detecting the probability of endodontic filling. However, the system showed variable performance in other categories, with lower accuracy metrics and unacceptable F1 scores for short filling and voids in filling assessments (8.33% and 14.29%, respectively). The accuracy for detecting adequate obturation and density was 55.81% and 62.79%, respectively. Conclusions: The AI-based system showed very high accuracy in identifying endodontically treated teeth but exhibited variable diagnostic accuracy for other qualitative features of endodontic treatment.

29 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RWRóża Wajer
Róża Wajer
AWAdrian Wajer
Adrian Wajer
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
JWJustyna Wilamowska
Justyna Wilamowska
ZSZbigniew Serafin
Zbigniew Serafin
Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Methods: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with ClariCT. AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. Results: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p<0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p<0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. Conclusion: AI-based noise reduction using ClariCT. AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.

29 October 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
RWRóża Wajer
Róża Wajer
OKOskar Komisarek
Oskar Komisarek
Marta Dyszkiewicz KonwinskaMarta Dyszkiewicz Konwinska
Marta Dyszkiewicz Konwinska
AWAdrian Wajer
Adrian Wajer
ZSZbigniew Serafin
Zbigniew Serafin
Background/Objectives: To assess the impact of a vendor-agnostic deep learning model (DLM) on image quality parameters and noise reduction in dental cone-beam computed tomography (CBCT) reconstructions. Methods: This retrospective study was conducted on CBCT scans of 93 patients (41 males and 52 females, mean age 41.2 years, SD 15.8 years) from a single center using the inclusion criteria of standard radiation dose protocol images. Objective and subjective image quality was assessed in three predefined landmarks through contrast-to-noise ratio (CNR) measurements and visual assessment using a 5-point scale by three experienced readers. The inter-reader reliability and repeatability were calculated. Results: Eighty patients (30 males and 50 females; mean age 41.5 years, SD 15.94 years) were included in this study. The CNR in DLM reconstructions was significantly greater than in native reconstructions, and the mean CNR in regions of interest 1-3 (ROI1-3) in DLM images was 11.12 ± 9.29, while in the case of native reconstructions, it was 7.64 ± 4.33 (p < 0.001). The noise level in native reconstructions was significantly higher than in the DLM reconstructions, and the mean noise level in ROI1-3 in native images was 45.83 ± 25.89, while in the case of DLM reconstructions, it was 35.61 ± 24.28 (p < 0.05). Subjective image quality assessment revealed no statistically significant differences between native and DLM reconstructions. Conclusions: The use of deep learning-based image reconstruction algorithms for CBCT imaging of the oral cavity can improve image quality by enhancing the CNR and lowering the noise.