Sedighe babaei Sedaghat

Dr. Sedighe babaei Sedaghat


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2026 in Results in Optics
Verified
Journal Article
Open access
HFHengameh Farokhi
Hengameh Farokhi
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat

31 March 2026 in Journal of Optics
Verified
Journal Article
Closed access
HFHengameh Farokhi
Hengameh Farokhi
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat

27 February 2026 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
HFHengameh Farrokhi
Hengameh Farrokhi
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat

1 January 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat
BGBahram.A Ganji
Bahram.A Ganji
This paper will focus on design, fabrication and characterization of a new MEMS capacitive microphone with the perforated diaphragm supported by Z-shape arms using SOI wafer. The aim is to fabricate a new microphone with the smallest size, simple and low cost. The novelty is making Z-shape arms around of diaphragm on SOI wafer using only a mask to decrease diaphragm stiffness and air damping and thus improve microphone performances. The fabricated structure has a diaphragm thickness of 5 µm, a diaphragm size of 0.3 mm × 0.3 mm, and an air gap of 1 µm. The results show that the pull-in voltage is 10.3 V, open circuit sensitivity of 2.46 mV/Pa, and resonance frequency of 60 kHz. The fabrication process uses minimal number of layers and masks due to using SOI wafer to reduce fabrication time and cost. The specific geometry of the proposed diaphragm causes the new fabricated microphone has low bias voltage, good sensitivity and smallest size compared with previous works.

1 January 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat
In this paper, a 0.29 V, 2 GHz CMOS low noise amplifier (LNA) intended for ultra low voltage and ultra low power applications is developed. The circuit is simulated in standard 0.18 m CMOS MOSIS. A two-stage architecture is then used to simultaneously optimize the gain and noise performance. Using forwardbody-biased, the proposed LNA can operate at 0.29 V supply voltage, successfully demonstrating the application potential of dynamic threshold voltage technology in the radio frequency region. The LNA provides a good gain of 26.25 dB, a noise figure of 2.202 dB, reverse isolation (S 12) of-59.04 dB, input return loss (S 11) of-122.66 dB and output return loss (S 22) of-11.61 dB, while consuming only 0.96mW dc power with an ultra low supply voltage of 0.29 V. To the best of authors' knowledge this is the lowest voltage supply and the lowest power consumption CMOS LNA design reported for 2 GHz to date.

1 January 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SSSedighe babaei Sedaghat
Sedighe babaei Sedaghat
HFHengameh Farrokhi
Hengameh Farrokhi
A compact metal-insulator-metal (MIM) plasmonic sensor based on a single Fano resonance is proposed and numerically optimized for high-performance refractive index (RI) sensing and blood plasma concentration (PC) detection. The sensing structure consists of a semicircular resonator coupled to a waveguide and a semi-elliptical cavity, forming a simplified configuration that supports Fano interference without relying on multi-resonator or multichannel architectures. Finite-difference time-domain (FDTD) simulations demonstrate a high RI sensitivity of 452.94 nm/RIU, a figure of merit of 50 RIU⁻¹, and an ultra-low detection limit of 2.21 × 10⁻⁵ RIU at a spectral resolution of 0.01 nm. Despite its structural simplicity, the proposed sensor achieves a modified figure of merit of 2.729, indicating competitive performance compared with recently reported Fano-based MIM sensors. The sensor exhibits a linear spectral response, enabling precise detection of small RI variations relevant to biomedical diagnostics. For blood plasma analysis, a direct sensing approach is employed, yielding a plasma concentration sensitivity of 0.2751 (nm•L)/g over a realistic concentration range, addressing limitations of previous studies based on impractical concentration assumptions. The proposed platform combines simplicity, linearity, and high sensitivity, making it a promising candidate for integrated lab-on-chip blood plasma biosensing applications.