Chunxing Wang

Dr. Chunxing Wang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2017 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ZZZhijie Zhang
Zhijie Zhang
CWChunxing Wang
Chunxing Wang
LZLiren Zhang
Liren Zhang
QMQingtian Meng
Qingtian Meng
YZYuemin Zhang
Yuemin Zhang
YXYuanda Xu
Yuanda Xu
In recent years, high demands on food safety technology have made precision and accurate detection technology an urgent research topic. This paper presents a novel biochemical system prototype for colony counting of Escherichia coli using a nano-probe associated with adenosine triphosphate (ATP). The novelty of this system is that the magnetic nanoparticle microbeads are modified with specific antibodies as a probe to capture and enrich the E. coli (Escherichia coli) via the specific connection between antigen and antibody. An experimental test-prototype has been developed in which the light is emitted by an ATP bioluminescence mechanism, the light signal is transformed into an electric signal through a photoelectric multiplier tube, and the quantity of E. coli can be rapidly detected indirectly by a signal processing module. For a testing period of less than twenty minutes, the detectable bacteria concentration range reaches 102–108 CFU mL−1. Under optimal testing conditions, the limit of detection (LOD) is only 3.0 × 102 CFU mL−1. The data measured in independent experiments show that the maximum fluctuation value of the SNR (signal to noise ratio) is below 6.98% which demonstrates that the prototype has excellent reliability and repeatability. The signal processing module consists of a high-precision chopper amplifier with differential magnification up to 3010 times and a SNR less than 50 dB. Furthermore, the linear correlation coefficient of the prototype is 0.964. It can be seen that the system performance is significant.

14 July 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ZSZhen Sun
Zhen Sun
JGJia Guo
Jia Guo
WWWenbo Wan
Wenbo Wan
CWChunxing Wang
Chunxing Wang
Bacterial contamination is an important factor causing food security issues. Among the bacteria, Escherichia coli is one of the main pathogens of food-borne microorganisms. However, traditional bacterial detection approaches cannot meet the requirements of real-time and on-site detection. Thus, it is of great significance to develop a rapid and accurate detection of bacteria in food to ensure food safety and safeguard human health. The pathogen heat-treatment module was designed in this paper based on the techniques including nanoprobe, pathogen heat-treatment, graphene transparent electrode (GTE), and adenosine triphosphate (ATP) bioluminescence technology. The system mainly consists of two parts: one is the optical detection unit; the other is the data processing unit. And it can quickly and automatically detect the number of bacterial colonies in food such as milk etc. The system uses not only the probe to capture and enrich E. coli by antigen-antibody interaction but also the heat treatment to increase the amount of ATP released from bacterial cells within five minutes. To enhance the detecting accuracy and sensitivity, the electric field generated by GTE is adopted in the system to enrich ATP. Compared to the other conventional methods, the linear correlation coefficient of the system can be reached 0.975, and the system meets the design requirements. Under the optimal experimental conditions, the detection can be completed within 25 min, and the detectable concentration of bacteria is in the range of 3.1 × 101–106 CFU/mL. This system satisfies the demands of a fast and on-site inspection.

27 October 2012 in European Food Research and Technology
Verified
Journal Article
Closed access
PDF file
CWChunxing Wang
Chunxing Wang
BZBin Zhang
Bin Zhang
XZXiaomei Zhuang
Xiaomei Zhuang

25 August 2017 in Information
Verified
Journal Article
Open access
PDF file
CWChunxing Wang
Chunxing Wang
TZTeng Zhang
Teng Zhang
WWWenbo Wan
Wenbo Wan
XHXiaoyue Han
Xiaoyue Han
MXMeiling Xu
Meiling Xu
The just noticeable distortion (JND) model plays an important role in measuring the visual visibility for spread transform dither modulation (STDM) watermarking. However, the existing JND model characterizes the suprathreshold distortions with an equal saliency level. Visual saliency (VS) has been widely studied by psychologists and computer scientists during the last decade, where the distortions are more likely to be noticeable to any viewer. With this consideration, we proposed a novel STDM watermarking method for a monochrome image by exploiting a visual saliency-based JND model. In our proposed JND model, a simple VS model is employed as a feature to reflect the importance of a local region and compute the final JND map. Extensive experiments performed on the classic image databases demonstrate that the proposed watermarking scheme works better in terms of the robustness than other related methods.

20 July 2018 in Information
Verified
Journal Article
Open access
PDF file
CWChunxing Wang
Chunxing Wang
XHXiaoyue Han
Xiaoyue Han
WWWenbo Wan
Wenbo Wan
JLJing Li
Jing Li
JSJiande Sun
Jiande Sun
MXMeiling Xu
Meiling Xu
It has been known that human visual systems (HVSs) can be applied to describe the underlying masking properties for the image processing. In general, HVS can only perceive small changes in a scene when they are greater than the just noticeable distortion (JND) threshold. Recently, the cognitive resources of huma visual attention mechanisms are limited, which can not concentrate on all stimuli. To be specific, only more important stimuli will react from the mechanisms. When it comes to visual attention mechanisms, we need to introduce the visual saliency to model the human perception more accurately. In this paper, we presents a new wavelet-based JND estimation method that takes into account the interrelationship between visual saliency and JND threshold. In the experimental part, we verify it from both subjective and objective aspects. In addition, the experimental results show that extracting the saliency map of the image in the discrete wavelet transform (DWT) domain and then modulating its JND threshold is better than the non-modulated JND effect.

17 March 2009 in Chinese Physics B
Verified
Journal Article
Closed access
YDYue Da-Guang
Yue Da-Guang
ZXZheng Xiao-Yun
Zheng Xiao-Yun
LHLiu Hao
Liu Hao
CWChunxing Wang
Chunxing Wang
MQMeng Qing-Tian
Meng Qing-Tian