In this study, a controllable mass‒frequency tuning method is presented using the etching of rib structures on a single-crystal PZT membrane. The rib structures were optimized to reduce the membrane mass while maintaining the stiffness; therefore, the center frequency could be increased to improve the low-frequency bandwidth of microphones. Additionally, this methodology could reduce the modulus and improve the sensitivity for the same resonant frequency, which typically indicates the maximum acoustic overload point (AOP). The PZT film was chosen because of its greater density; the simulation results showed that PZT could provide a greater frequency tuning (24.9%) compared to that of the AlN film (5.8%), and its large dielectric constant enabled the optimal design to have small electrodes at the maximum stress location while mitigating the sacrificial capacitance effect on electrical gain. An analytical model of rib-structure microphones was established and greatly reduced the computing time. The experimental results of the impedance tests revealed that the center frequencies of the six microphones shifted from 74.6 kHz to 106.3 kHz with rib-structure inner radii ranging from 0 μm to 340 μm; this result was in good agreement with the those of the analytical analysis and finite element modeling. While the center frequency greatly varied, the measured sensitivities at 1 kHz only varied within a small range from 22.3 mV/Pa to 25.7 mV/Pa; thus, the membrane stiffness minimally changed. Moreover, a single-crystal PZT film with a (100) crystal orientation and 0.24-degree full width at half maximum (FWHM) was used to enable differential sensing and a low possibility of undesirable polarization. Paired with a two-stage differential charge amplifier, a differential sensing microphone was experimentally demonstrated to improve the sensitivity from 25.7 mV/Pa to 36.1 mV/Pa and reduce the noise from −68.2 dBV to −82.8 dBV.
14 May 2024 in Journal of Microelectromechanical Systems
The demand for high-performance lead-free piezoelectric ultrasound transducers has grown significantly, driven by their applications in implantable, biocompatible medical devices and environmentally friendly consumer electronics. In this study, we present the design, fabrication, and characterization of arrays of lead-free (K, Na)NbO $_{3}$ (KNN)-based piezoelectric micromechanical ultrasonic transducers (PMUTs) with a center frequency of 4.7 MHz in liquid and 5.85 MHz in air. High-quality KNN thin film (FWHM of 0.32 $^{\circ}$ , $e_{\mathrm{31,}f}=$$-$ 12 C/m $^{2}$ , $\epsilon _{r}$$=$ 1200) was deposited via physical vapor deposition (PVD) and patterned using an optimized wet etching process with an oxide layer as a mask. Additionally, we obtained a $-$ 6 dB fractional bandwidth of 95.7% through optimizing layer stacks and transducers mutual acoustic impedance based on finite element model (FEM) and lumped element model (LEM) methods. We achieved high transmitting performance of 3.8 kPa/V at 3 cm away from a PMUT super-pixel (with an area of 0.278 mm $^{2}$ , consisting of $3\times 12$ PMUTs). The measured transducer performance is comparable to previous PMUTs based on PZT (lead-included) thin films and demonstrates the potential of KNN-based PMUTs in future advanced applications. 2024-0005
9 May 2024 in Journal of Microelectromechanical Systems
In this paper, we present air-coupled lead-zirconate-titanate (PZT) piezoelectric micromachined ultrasonic transducers (PMUTs) which demonstrate ultra-wide frequency tuning range via controllable in-plane stress generated by DC bias voltage. A PMUT designed to have a resonant frequency of $\sim$ 200kHz generates a 223kHz total frequency shift from 182.5kHz to 405.5kHz with $\pm$ 35V DC bias (corresponding to 97.8% variation referring to the resonant frequency without bias), and a 124kHz frequency shift from 188kHz to 312kHz with $\pm$ 10V DC bias (corresponding to 54.4% variation). The effects of DC bias tuning were further characterized by both impedance analyzer and laser Doppler vibrometer (LDV), the fluctuation of electromechanical coupling coefficient ( ${k}_{\mathbf{t}}^{\mathbf{2}}$ ) and the change of the direction of polarization of the piezoelectric layer were successfully observed. Frequency tuning along different curves of the hysteresis loop was studied, and given both reasonably good ${k}_{\mathbf{t}}^{\mathbf{2}}$ ( $>$ 5%) and frequency tuning sensitivity ( $>$ 10kHz/V), a 188.5kHz to 254kHz frequency tuning with 1 $\sim$ 6V DC bias is chosen from the best option of the hysteresis loop. Furthermore, characteristics of PMUTs with different top electrode thickness were studied and summarized, and thinner top electrode was considered as an optimization method to achieve better performance for PMUT under DC bias in terms of frequency tuning. PMUTs with various frequencies were evaluated, and measurement results show a smaller tuning range of PMUTs with higher resonant frequency than those with lower resonant frequency due to the different membrane modulus, and, therefore different contributions of intrinsic stress generated by DC bias to the overall membrane modulus. 2024-0036
1 October 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
This study presents a high-fill-factor piezoelectric micromachined ultrasonic transducer (PMUT) array fabricated via the cavity silicon-on-insulator (CSOI) process. The center frequency of the PMUT is 4.89 MHz in air and 3.5 MHz in a gel-type couplant, along with a −6 dB photoacoustic (PA) bandwidth of 146%. A miniaturized PA sensing system (4.6 mm × 2.0 mm × 5.2 mm) was developed by integrating the PMUT with a compact vertical-cavity surface-emitting laser (VCSEL). Simulation results reveal critical parameters for optimizing a PA system. The increase in laser excitation energy correspondingly improves the efficiency of PA signal generation, and spatial non-uniformity in optical energy distribution requires algorithmic compensation to prevent signal distortion. The small footprint of the PMUT minimizes phase differences, enabling distortion-free signal detection at close range, while its broad bandwidth ensures high-fidelity signal capture at an optimized center frequency. Guided by these findings, the VCSEL parameters were optimized to a 28 ns pulse width and an average output power of 63.6 μW. Comprehensive characterization, including electrical impedance, acoustic response, and PA bandwidth tests, demonstrated the consistency of the PMUT fabrication process, broadband capability and superiority of the PMUT in close-range sensing. Phantom-based testing showed that the system can acquire multi-depth phantom signals, and the cylindrical wave radiation analysis further highlighted the critical role of laser-PMUT spacing in maintaining signal integrity. This feasibility study validates the compact system as a promising platform for portable PA devices under ideal phantom and ex vivo conditions.
22 August 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Ultrasound propagation attenuation coefficient detection is a widely used technique for distinguishing different media types. Multifrequency ultrasound detection provides comprehensive information but requires ultrasonic transducers with a broad bandwidth. This study presents a piezoelectric micromachined ultrasonic transducer (PMUT) array that integrates multiple frequency elements with optimized spacing to achieve the fusion of multiple vibration modes, resulting in a −6 dB emission fractional bandwidth of 230% and pulse-echo fractional bandwidth up to 146%. This ultrawide bandwidth facilitates accurate pulse-echo signal reception across a broad frequency range while minimizing signal overlap caused by ringdown effects. Moreover, optimizing the PMUT array size relative to wavelength achieved a highly directional 5° acoustic beam, ensuring effective penetration through high attenuation or multilayered structures. Experimental results indicate that attenuation coefficients in ice and liquid correlate with their material composition and structural properties. These findings highlight the significant potential of the PMUT array for identifying and analyzing surface media, with promising applications in power supply systems, transportation, industrial production, and so on.
10 December 2025 in Microsystems & Nanoengineering
This paper demonstrated the feasibility of utilizing miniaturized piezoelectric micromachined ultrasonic transducer (PMUT) to form a symmetric V-shaped acoustic beam pattern, which enables the ability to synchronously transmit bidirectional ultrasonic signals, and offers a promising technology to address the frame rate limitations in traditional ultrasonic flowmeters based on time-of-flight (ToF). In contrast to the previous two-step flow rate monitoring scheme, where paired ultrasonic transducers are used as transmitter and receiver alternately to obtain the upstream and downstream ultrasound propagation time sequentially, we proposed one-step mid-air flow rate measurement with a remarkable frame rate through the V-shaped bidirectional beam generated by a 3.6 mm × 3.6 mm 5-channel ~250 kHz PZT PMUT phased array. By utilizing the grating lobe produced through optimized array pitch design and sequential control, this 5-channel PMUT array breaks the conventional design limitations typically associated with grating lobes, and generates the V-shaped beam with dual main lobes measured at 27° and 153°, enabling 1000 times of upstream and downstream ToF measurements in 1 s. Furthermore, installation geometry optimization was proposed to enhance the ToF resolution and adaptation to various pipe circumstances, where flow rate measurements in conventional straight pipe and optimized zigzag-shaped pipe with 150 mm sufficient ultrasound propagation length were investigated. The experiment results demonstrated the superior flow rate monitoring performance of our device and system, where large-range (0.5–35 L·min–1 or 0.045–3.177 m·s–1, airflow) and high-resolution (185 ns/(L·min–1) or 2032 ns/(m·s–1)) flow metering with significant linearity (0.997) was successfully obtained, revealing great potential in advanced flow monitoring application scenarios.