A great challenge for 21 cm intensity mapping experiments is the strong foreground radiation which is orders of magnitude brighter than the 21 cm signal. Removal of the foreground takes advantage of the fact that its frequency spectrum is smooth while the redshifted 21 cm signal spectrum is stochastic. However, a complication is the non-smoothness of the instrument response. This paper describes the electromagnetic simulation of the Tianlai cylinder array, a pathfinder for 21 cm intensity mapping experiments. Due to the vast scales involved, a direct simulation requires a large amount of computing resources. We have made the simulation practical by using a combination of methods: first simulate a single feed, then an array of feed units, finally with the feed array and a cylindrical reflector together, obtain the response for a single cylinder. We studied its radiation pattern, bandpass response and the effects of mutual coupling between feed units, and compared the results with observation. Many features seen in the measurement result are reproduced well in the simulation, especially the oscillatory features which are associated with the standing waves on the reflector. The mutual coupling between feed units is quantified with S -parameters, which decrease as the distance between the two feeds increases. Based on the simulated S -parameters, we estimate the correlated noise which has been seen in the visibility data, and the results show very good agreement with the data in both magnitude and frequency structures. These results provide useful insights on the problem of 21 cm signal extraction for real instruments.
The redshifted 21 cm line signal is a powerful probe of the cosmic dawn and the epoch of reionization. The global spectrum can potentially be detected with a single antenna and spectrometer. However, this measurement requires an extremely accurate calibration of the instrument to facilitate the separation of the 21 cm signal from the much brighter foregrounds and possible variations in the instrument response. Understanding how the measurement errors propagate in a realistic instrument system and affect system calibration is the focus of this work. We simulate a 21 cm global spectrum observation based on the noise wave calibration scheme. We focus on how measurement errors in reflection coefficients affect the noise temperature and how typical errors impact the recovery of the 21 cm signal, especially in the frequency domain. Results show that for our example set up, a typical vector network analyzer (VNA) measurement error in the magnitude of the reflection coefficients of the antenna, receiver, and open cable, which are 0.001, 0.001, and 0.002 (linear), respectively, would result in a 200 mK deviation on the detected signal, and a typical measurement error of , , or in the respective phases would cause a 40 mK deviation. The VNA measurement error can greatly affect the result of a 21 cm global spectrum experiment using this calibration technique, and such a feature could be mistaken for or be combined with the 21 cm signal.
15 December 2025 in Research in Astronomy and Astrophysics
The Tianlai Cylinder Pathfinder Array consists of three adjacent cylindrical reflectors fixed on the ground, each 40 m long and 15 m wide, with the cylinder axis oriented along the North–South (N–S) direction. Dual linear polarization feeds are distributed along the focus line, parallel to the cylinder axis. Measurement of the primary beam profile of these cylindrical reflectors is difficult, as they are too large to be placed in an anechoic chamber. While the beam profile along the East–West (E–W) direction can be measured with the transit observations of bright astronomical radio sources, the beam profile along the N–S direction remains very uncertain. We present a preliminary measurement of the beam profile of the Tianlai cylindrical antenna along both the N–S direction and E–W direction in the frequency range of 700–800 MHz, using a calibrator source carried by an unmanned aerial vehicle (UAV) flying in the far field. The beam profile of the Tianlai cylindrical antenna is determined from the analysis of the auto-correlation signals from the cylinder array correlator, taking into account the emitter antenna beam profile, itself measured with a dipole antenna on the ground. The accuracy of the UAV-based determination of the cylinder beam profiles is validated by comparing the results with the one derived from bright astronomical source transits, and with simulated beams.
The redshifted 21 cm line signal is a powerful probe of the cosmic dawn and the epoch of reionisation. The global spectrum can potentially be detected with a single antenna and spectrometer. However, this measurement requires an extremely accurate calibration of the instrument to facilitate the separation of the 21 cm signal from the much brighter foregrounds and possible variations in the instrument response. Understanding how the measurement errors propagate in a realistic instrument system and affect system calibration is the focus of this work. We simulate a 21 cm global spectrum observation based on the noise wave calibration scheme. We focus on how measurement errors in reflection coefficients affect the noise temperature, and how typical errors impact on the recovery of the 21 cm signal, especially in the frequency domain. Results show that for our example set up, a typical VNA measurement error in the magnitude of the reflection coefficients of the antenna, receiver, open cable which are 0.001, 0.001, 0.002 (linear) respectively would result in a 200 mK deviation on the detected signal, and a typical measurement error of 0.48∘, 0.78∘, 0.15∘ in the respective phases would cause a 40 mK deviation. The VNA measurement error can greatly affect the result of a 21 cm global spectrum experiment using this calibration technique, and such a feature could be mistaken for or be combined with the 21 cm signal.
The Tianlai Pathfinder is designed to demonstrate the feasibility of using a wide field of view radio interferometers to map the density of neutral hydrogen in the Universe after the Epoch of Reionizaton. This approach, called 21~cm intensity-mapping, promises an inexpensive means for surveying the large-scale structure of the cosmos. The Tianlai Pathfinder presently consists of an array of three, 15~m $\times$ 40~m cylinder telescopes and an array of sixteen, 6~m diameter dish antennas located in a radio-quiet part of western China. The two types of arrays were chosen to determine the advantages and disadvantages of each approach. The primary goal of the Pathfinder is to make 3D maps by surveying neutral hydrogen over large areas of the sky %$20,000 {\rm deg}^2$ in two different redshift ranges: first at $1.03 > z > 0.78$ ($700 - 800$~MHz) and later at $0.21 > z > 0.12$ ($1170 - 1270$~MHz). The most significant challenge to $21$~cm intensity-mapping is the removal of strong foreground radiation that dwarfs the cosmological signal. It requires exquisite knowledge of the instrumental response, i.e. calibration. In this paper, we provide an overview of the status of the Pathfinder and discuss the details of some of the analysis that we have carried out to measure the beam function of both arrays. We compare electromagnetic simulations of the arrays to measurements, discuss measurements of the gain and phase stability of the instrument, and provide a brief overview of the data processing pipeline.
The redshifted 21 cm line, arising from neutral hydrogen, offers a unique probe into the intergalactic medium and the first stars and galaxies formed in the early universe. However, detecting this signal is a challenging task because of artificial radio-frequency interference (RFI) and systematic errors such as ground effects. The interior of the Antarctic continent provides an excellent location to make such observations, with minimal RFI and relatively stable foreground signals. Moreover, a flat plateau in central Antarctica, with an ice cap over 2000 m deep, will show less ground reflection of radio waves, reducing the signal complexity in the area around the probing antenna. It may be advantageous to perform cosmological 21 cm experiments in Antarctica, and a 21 cm Antarctic global spectrum experiment can potentially be deployed on the Antarctic ice cap. We have performed preliminary instrumental design, system calibration, and implementation of such an instrument optimized for extreme cold and capable of long-term autonomous operation. This system shows the ability to effectively detect the 21~cm signal, confirming Antarctica as an excellent observational site for radio cosmology.