Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK
Associate Professor in Electronics and Nanotechnology
Dr. Shakil Ahmed Awan
Wolfson Nanomaterials and Devices Laboratory, School of Computing, Electronics and Mathematics, Faculty of Science and Engineering, University of Plymouth, Plymouth PL4 8AA, UK
Associate Professor in Electronics and Nanotechnology
The authors have between them more than 60 years of experience in making electrical measurements in National Measurement Laboratories. These laboratories are the source of measurement standards and techniques for science and engineering and are dedicated to maintaining the international system of units (SI) by establishing and disseminating the values of measurement standards with the lowest possible uncertainty. Careful attention to detail is required in designing measurement systems that eliminate electrical interference and are as simple and as close to first principles as possible. This book draws on their experience by offering guidance and best practice for designing sensitive electrical measurement circuits. In particular the book describes examples that demonstrate the elegance, flexibility and utility of balanced-current coaxial networks in obtaining the ultimate in noise-matching and interference elimination for precise and accurate voltage, current and power measurements. It also updates an earlier book on coaxial AC bridges by including recent AC measurements of quantum Hall resistance to establish a primary quantum standard of impedance and by extending impedance measurements in general to higher frequencies.
We measure graphene coplanar waveguides from direct current (DC) to a frequency f = 13.5 GHz and show that the apparent resistance (in the presence of parasitic impedances) has an dependence (where ), but the intrinsic conductivity (without the influence of parasitic impedances) is frequency-independent. Consequently, in our devices the real part of the complex alternating current (AC) conductivity is the same as the DC value and the imaginary part is ~0. The graphene channel is modeled as a parallel resistive–capacitive network with a frequency dependence identical to that of the Drude conductivity with momentum relaxation time ~2.1 ps, highlighting the influence of AC electron transport on the electromagnetic properties of graphene. This can lead to optimized design of high-speed analog field-effect transistors, mixers, frequency doublers, low-noise amplifiers and radiation detectors.
We report on the development of label-free chemical vapour deposition (CVD) graphene field effect transistor (GFET) immunosensors for the sensitive detection of Human Chorionic Gonadotropin (hCG), a glycoprotein risk biomarker of certain cancers. The GFET sensors were fabricated on Si/SiO2 substrate using photolithography with evaporated chromium and sputtered gold contacts. GFET channels were functionalised with a linker molecule to an immobile anti-hCG antibody on the surface of graphene. The binding reaction of the antibody with varying concentration levels of hCG antigen demonstrated the limit of detection of the GFET sensors to be below 1 pg/mL using four-probe electrical measurements. We also show that annealing can significantly improve the carrier transport properties of GFETs and shift the Dirac point (Fermi level) with reduced p-doping in back-gated measurements. The developed GFET biosensors are generic and could find applications in a broad range of medical diagnostics in addition to cancer, such as neurodegenerative (Alzheimer’s and Parkinson’s ) and cardiovascular disorders.
1 January 2021 in Ecotoxicology and Environmental Safety
Potable water in developing countries often contains levels of toxic metals that exceed the recommended international limits, with impacts on human health. The aim of the present study was to develop a low cost aerogel synthesised from graphene oxide (GO) cross-linked with alginate to remove Pb2+ from potable water. Aerogels were made by a sol-gel of the composite materials followed by a freeze drying method. The shape of the aerogels were 50 mm diameter disks, 5 mm deep and characterised by an open porous network of 50 to 150 micrometres which are mechanically robust upon hydration. Firstly, the study was conducted using a batch adsorption method from a starting concentration 0.48 mM (100 mg/l) of Pb2+ in ultrapure water over 240 min, n = 4 with controls. A second series of experiments compared the adsorption of different competing ions at different valencies (Na+, Ca2+, Cu2+, La3+) in an equivalent media. A third series of experiments explored Pb2+ desorption from the aerogel at low pH and in highly acidic conditions. This simple filter system, based on a batch adsorption methodology expresses a high affinity for Pb2+ resulting in an ultra-high mean maximum adsorption capacity of 504 mg/g of Pb2+ within 240 mins at pH 5. The aerogel can also adsorb other toxic metal salts such as La3+ and Cu2+ with a capacity of 146 and 193 mg/g respectively. Furthermore, the aerogel structure can be acid washed removing 98% of the Pb2+ from the structure within three minutes. Overall, the data shows that GO alginate aerogels are highly effective at removing Pb2+ from water and the primary mechanism involved is ion exchange, although other phenomenon such as proton tunnelling may be a contributing factor to the ultra-high efficiency of the aerogel for Pb2+ remediation.
26 March 2021 in Frontiers in Molecular Biosciences
We report on the fabrication and characterisation of graphene field-effect transistor (GFET) biosensors for the detection of Clusterin, a prominent protein biomarker of Alzheimer’s disease (AD). The GFET sensors were fabricated on Si/SiO2 substrate using photolithographic patterning and metal lift-off techniques with evaporated chromium and sputtered gold contacts. Raman Spectroscopy was performed on the devices to determine the quality of the graphene. The GFETs were annealed to improve their performance before the channels were functionalized by immobilising the graphene surface with linker molecules and anti-Clusterin antibodies. Concentration of linker molecules was also independently verified by absorption spectroscopy using the highly collimated micro-beam light of Diamond B23 beamline. The detection was achieved through the binding reaction between the antibody and varying concentrations of Clusterin antigen from 1 to 100 pg/mL, as well as specificity tests using human chorionic gonadotropin (hCG), a glycoprotein risk biomarker of certain cancers. The GFETs were characterized using direct current (DC) 4-probe electrical resistance (4-PER) measurements, which demonstrated a limit of detection of the biosensors to be ∼ 300 fg/mL (4 fM). Comparison with back-gated Dirac voltage shifts with varying concentration of Clusterin show 4-PER measurements to be more accurate, at present, and point to a requirement for further optimisation of the fabrication processes for our next generation of GFET sensors. Thus, we have successfully fabricated a promising set of GFET biosensors for the detection of Clusterin protein biomarker. The developed GFET biosensors are entirely generic and also have the potential to be applied to a variety of other disease detection applications such as Parkinson’s, cancer, and cardiovascular.