Jörg Manfred Hoffmann

Prof. Dr. Jörg Manfred Hoffmann


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2024 in Journal of Advanced Research in Applied Mechanics
Verified
Journal Article
Open access
PDF file
FKFong Mun Kit
Fong Mun Kit
RHReazul Haq Abdul Haq
Reazul Haq Abdul Haq
Bukhari ManshoorBukhari Manshoor
Bukhari Manshoor
MGMohammad Fahmi Abdul Ghafir
Mohammad Fahmi Abdul Ghafir
MRMohd Nasrull Abdol Rahman
Mohd Nasrull Abdol Rahman
RKRd Khairilhijra' Khirotdin
Rd Khairilhijra' Khirotdin
The present study aimed to investigate the mechanical properties of recycled Polyethylene Terephthalate (r-PET) and Polycarbonate (PC) composites, with the incorporation of Methylene Diphenyl Diisocyanate. The primary objective was to identify the optimal composition for achieving superior mechanical performance. The composition under examination comprises four ratios, namely r-PET/PC1 (20/80), r-PET/PC2 (40/60), r-PET/PC3 (60/40), and r-PET/PC4 (80/20), expressed as weight percentages. The concentration of MDI utilized in the experiment was maintained at a constant level of 0.9% based on weight. The r-PET/PC/MDI composite underwent blending using a Brabender Plastograph prior to being introduced into the injection moulding process for sample production. The mechanical properties can be ascertained through the analysis of data acquired through mechanical testing, encompassing Tensile tests, Flexural tests, and Impact tests. The findings indicate that there is an inverse relationship between the percentage of r-PET in the blend and the tensile strength, with an increase in r-PET resulting in a decrease in tensile strength. Conversely, there is a positive relationship between the percentage of r-PET and Young's modulus, with an increase in r-PET leading to an increase in Young's modulus. The flexural strength and flexural modulus exhibit variations as the r-PET content increases in the r-PET/PC/MDI blend. Lastly, it can be observed that the impact strength reduces as the proportion of r-PET in the blend increases. The findings of this experiment indicate that the composition of r-PET/PC1 yielded the most favourable results. The composition under investigation demonstrated the greatest recorded tensile strength, measuring 22.30 MPa, as well as the second highest flexural strength, measuring 119.77 MPa. However, the impact strength of r-PET/PC1 exhibited the greatest value compared to the other samples, measuring 0.32J. In summary, the findings indicate that the mechanical characteristics of the r-PET/PC/MDI mix can be improved through the optimization of PC content, hence enhancing the features of r-PET.

16 December 2023 in Journal of Advanced Research in Applied Sciences and Engineering Technology
Verified
Journal Article
Open access
PDF file
FKFong Mun Kit
Fong Mun Kit
NZNicolas Ng Yang Zu
Nicolas Ng Yang Zu
RHReazul Haq Abdul Haq
Reazul Haq Abdul Haq
Bukhari ManshoorBukhari Manshoor
Bukhari Manshoor
MGMohammad Fahmi Ghafir
Mohammad Fahmi Ghafir
JHJörg Manfred Hoffmann
Jörg Manfred Hoffmann
An electrode is a vital transmission tool of electrical charges that erodes a workpiece surface in die-sinking electrical discharge machining (EDM). However, the demanding requirements of the geometrical complexity and accuracy of an electrode significantly affected its manufacturing cost and time. Therefore, rapid tooling (RT) was attempted to improve electrode manufacturing. This research aims to verify the application of the FDM electrode in die-sinking EDM. Furthermore, the metallization and the machining performance of the FDM electrode were also studied. Fused Deposition Modelling (FDM) was utilized to fabricate a cylindrical electrode core made of Polyethylene Terephthalate Glycol (PETG). In primary metallization, the electrode core was immersed in copper paint. Next, the coated PETG substrate was electroplated in secondary metallization at a current density of 0.023 A cm-2 for 168 hours (7 days). The electrolyte consists of 80 g/ℓ copper (II) sulphate pentahydrate and 20 ml/ℓ sulphuric acid. The machining performance of FDM electrode such as material removal rate (MRR), electrode wear rate (EWR) and surface roughness (SR) was benchmarked with a copper electrode. Copper coating with an average thickness of 334 µm was successfully electroplated on the surface of the FDM electrode. Additionally, the FDM electrode was able to machine the mild steel workpiece with 1 mm infit at a peak current of 16 A and pulse-on time of 50 µs without suffering premature electrode failures such as edge failure, delamination, distortion and rupturing. Lastly, the machining performance of the FDM electrode was comparable to the copper electrode in terms of MRR, EWR and SR. The potential of the FDM electrode in EDM machining is proven successful and can be investigated further to enhance the performance of this electrode.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
JJJule Janke
Jule Janke
WTWerner Trentmann
Werner Trentmann
JHJörg Manfred Hoffmann
Jörg Manfred Hoffmann
In history, many particle concentration measurement instruments operate by determining the mass concentration (e.g., filtering and mass determination). Therefore, the laws and rules concerning air pollution today are primarily based on the principle of mass concentration. The mass-(or volume-) concentration means how much of the particle mass (in percentage) from the total mass of the particles is in a defined size range. However, modern particle concentration measurement devices, in particular, optical devices, primarily operate by determining the number concentration (e.g., light scattering or light blockage). The number concentration indicates how many particles (in percentage) of the total number of particles are in a defined size range. These devices have a much higher sampling rate and resolution. In order to meet the legal requirements based on the mass concentration, the conversion from the number concentration to the mass concentration is necessary. Technically, such conversion would be possible assuming that all the particles have the same material density and are completely spherical in shape. However, both are not the case in most practical applications. The shape of particles usually deviates from the sphere, and their material density can differ in different size classes. In addition, humidity has an influence on the size of the particles. In this work, a machine learning approach for the calibration of particle concentration measurement system is proposed for a relatively stable particle composition from applications such as street fine dust. The novelty lies in the conversion rules from the number concentration to the mass concentration by means of a neural network. For this, the neural network must be trained with a reference device, which primarily determines the mass concentration. The proposed method enables wider adoption of optical devices for particle concentration measurement and the results are comparable with the mass concentration, used for laws and rules.


2 October 2024 in Journal of Advanced Research in Applied Mechanics
Verified
Journal Article
Open access
PDF file
FKFong Mun Kit
Fong Mun Kit
RHReazul Haq Abdul Haq
Reazul Haq Abdul Haq
YSYashvir Singh
Yashvir Singh
MGMohammad Fahmi Abdul Ghafir
Mohammad Fahmi Abdul Ghafir
MHMohd Fahrul Hassan
Mohd Fahrul Hassan
JHJörg Manfred Hoffmann
Jörg Manfred Hoffmann
In the study, an attempt was made to electrolessly plate copper onto PETG plastics that aren't conductors. Three manipulating factors, i.e. volume of copper sulphate and sulphuric acid (A), volume of sulphuric acid (B), and mass of copper sulphate (C), were selected and carried out using Taguchi method with three levels to examine their interactions and effects on the responses, including plating thickness, and electrical resistance. The Design Expert 13 software creates a total of nine runs with a single centre point. Three days were spent submerging every electroplated sample part in a different bath solution concentration. The resistance of the metalized PETG component was measured in the meantime using a digital multi-meter. The Cu-deposited PETG was analysed and measured using scanning electron microscopy (SEM). The ideal situation was identified as having 10 possibilities for achieving the goal, based on interaction effects. According to the results of the experiment, run number 3 provides the ideal solution parameter for copper deposition metallization. For the lowest electrical resistance of 0.64 ohm and the highest plating thickness value of 211.49 m, these runs yield the best ideal results. Because each factor reacts to a response individually, the Analysis of Variance (ANOVA) demonstrates that there are little interactions between the factors and responses. The lowest electrical resistance and highest plating thickness values are obtained with the best chemical composition parameter choices.