Surajit Das Barman

Mr. Surajit Das Barman


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
SBSurajit Das Barman
Surajit Das Barman
ARAhmed Wasif Reza
Ahmed Wasif Reza
NKNarendra Kumar
Narendra Kumar
EKErshadul Karim
Ershadul Karim
AMAbu Bakar Munir
Abu Bakar Munir

8 September 2023 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
SBSurajit Das Barman
Surajit Das Barman
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
SISyed Islam
Syed Islam
AKApurv Kumar
Apurv Kumar
This paper demonstrates a 2-D numerical model to represent two conceptual pyroCb thundercloud structures: i) tilted dipole and ii) tripole structure with enhanced lower positive charge layer, which are hypothesized to explain the occurrence of lightning flashes in pyrocumulonimbus storms created from severe wildfire events. In contrast to previous works, more realistic thundercloud charge structures are considered in the presented model to investigate the electrical states and obtain the surface charge density to identify the probable lightning-striking zone on the earth's surface. Simulation results on dipole structure based pyroCb thunderclouds confirm that the wind-shear extension of its upper positive charge reduces the electric field and indicates the initiation of negative surface charge density underneath the anvil cloud. For a lateral extension of the upper positive charge layer by 2–8 km, the probable striking zone for -CG lightning is confined within 0–23.5 km in the simulation domain and would expect +CG lightning to strike in the zone of 23.5 to 30 km around the earth periphery, particularly in the direction of the cloud's forward flank. On the other hand, pyroCb thundercloud possessing the tripole structure having an excessively lower positive charge develops a negative electric field at the cloud's bottom part to block the progression of the downward negative leader and cause the surface charge density beneath the thundercloud to become negative which would lead to the formation of +CG flashes. Later, a parametric study is conducted assuming a positive linear correlation between the charge density and aerosol concentration to examine the effect of high aerosol concentration on surface charge density in both pyroCb thunderclouds. The proposed model can be extended further into the 3-D domain to simulate the movement of lightning leaders which could facilitate a conceived risk planning management against wildfire-generated lightning events and secondary spot fires.

19 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SBSurajit Das Barman
Surajit Das Barman
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
SISyed Islam
Syed Islam
AKApurv Kumar
Apurv Kumar
Pyrocumulonimbus (pyroCb) thunderclouds, produced from extreme bushfires, can initiate frequent cloud-to-ground (CG) lightning strikes containing extended continuing currents. This, in turn, can ignite new spot fires and inflict massive harm on the environment and infrastructures. This study presents a 3D numerical thundercloud model for estimating the lightning of different types and its striking zone for the conceptual tripole thundercloud structure which is theorized to produce the lightning phenomenon in pyroCb storms. More emphasis is given to the lower positive charge layer, and the impacts of strong wind shear are also explored to thoroughly examine various electrical parameters including the longitudinal electric field, electric potential, and surface charge density. The simulation outcomes on pyroCb thunderclouds with a tripole structure confirm the presence of negative longitudinal electric field initiation at the cloud’s lower region. This initiation is accompanied by enhancing the lower positive charge region, resulting in an overall positive electric potential increase. Consequently, negative surface charge density appears underneath the pyroCb thundercloud which has the potential to induce positive (+CG) lightning flashes. With wind shear extension of upper charge layers in pyroCb, the lightning initiation potential becomes negative to reduce the absolute field value and would generate negative (−CG) lightning flashes. A subsequent parametric study is carried out considering a positive correlation between aerosol concentration and charge density to investigate the sensitivity of pyroCb electrification under the influence of high aerosol conditions. The suggested model would establish the basis for identifying the potential area impacted by lightning and could also be expanded to analyze the dangerous conditions that may arise in wind energy farms or power substations in times of severe pyroCb events.

1 October 2019 in International Journal of Machine Learning and Computing
Verified
Journal Article
Open access
KTKanij Tabassum
Kanij Tabassum
AMAfsana A. Memi
Afsana A. Memi
NSNasrin Sultana
Nasrin Sultana
ARAhmed Wasif Reza
Ahmed Wasif Reza
SBSurajit Das Barman
Surajit Das Barman

17 December 2025 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
SBSurajit Das Barman
Surajit Das Barman
SHShazzad Hossain
Shazzad Hossain
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
SISyed Islam
Syed Islam
S.M. MuyeenS.M. Muyeen
S.M. Muyeen
AKApurv Kumar
Apurv Kumar
Pyrocumulonimbus (pyroCb) thunderstorms from intense bushfires are major lightning sources, igniting secondary fires and damaging electrical infrastructure. Unlike conventional lightning surge studies based on generic thunderstorm conditions, this study develops a novel modeling framework rooted in atmospheric pyroCb thundercloud dynamics. A numerical model is employed to simulate downward leader propagation in pyroCb lightning via the dielectric breakdown model, explicitly coupling charge structure, wind-shear-driven displacement, and leader dynamics with surge analysis. Results show wind shear extensions of 0–12 km significantly influence charge distribution and lightning type, shifting from intracloud to negative cloud-to-ground (–CG) discharges as initiation potential changes from 49.34 MV (4 km extension) to –450.69 MV (12 km extension). Findings indicate that CG flashes predominantly strike within 26–27 km, emphasizing charge density variations in leader development. The extracted return stroke current, peaking at 350 kA, is modeled as a MATLAB time-series function and applied to a grid-connected photovoltaic (PV) system to analyze surge effects. Results show pyroCb lightning surges propagate through electrical networks, causing extreme overvoltages, equipment failure, and operational disruptions. By directly linking pyroCb atmospheric processes with renewable energy infrastructure response, this study makes the first integrated assessment of bushfire-driven lightning surges on PV systems. These findings emphasize the need to assess renewable energy infrastructure vulnerabilities to extreme weather-driven lightning events. By clarifying leader dynamics and surge impacts, this study advances lightning protection research and highlights the importance of robust mitigation strategies to safeguard electrical systems against pyroCb lightning hazards.

2 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SBSurajit Das Barman
Surajit Das Barman
Rakibuzzaman ShahRakibuzzaman Shah
Rakibuzzaman Shah
SISyed Islam
Syed Islam
AKApurv Kumar
Apurv Kumar
Pyrocumulonimbus (pyroCb) thunderclouds, produced from extreme bushfires, can initiate frequent cloud-to-ground (CG) lightning strikes containing extended continuing currents. This, in turn, can ignite new spotfires and inflict massive harm on the environment and infrastructures. This study presents a 3D numerical thundercloud model for estimating the lightning of different types and its striking zone for the conceptual tripole thundercloud structure which is theorized to elucidate the lightning phenomenon in pyroCb storms. More emphasis is given to the lower positive charge structure thundercloud to thoroughly examine various electrical parameters including the longitudinal electric field, electric potential, and surface charge density. The simulation outcomes on pyroCb thunderclouds with a tripole structure confirm the presence of negative longitudinal electric field initiation at the cloud’s lower region. This initiation is accompanied by enhancing the lower positive charge region, resulting in an overall positive electric potential increase. Consequently, negative surface charge density appears underneath the pyroCb thundercloud which has the potential to induce positive cloud-to-ground (+CG) lightning flashes. The suggested model would establish the basis for identifying the potential area impacted by lightning and could also be expanded to analyze the dangerous conditions that may arise in wind energy farms or power substations in times of severe pyroCb events.