An accurate method for the evaluation of 50-Hz magnetic fields produced by overhead power lines is presented. The method, which is based on the matrix formalism of multiconductor transmission lines (MTL), allows for a correct evaluation of all the currents flowing in the MTL structure, including the currents in the subconductors of each phase bundle, the currents in the ground wires, the currents in the mitigation loop (if present), and also the earth return currents. Furthermore, the analysis also incorporates the nonuniform character of the structure arising from conductor sagging between towers. Frequency domain magnetic field calculations are performed by vectorial sum of the magnetic effects originated by all the existing currents. For exemplification purposes the case of an actual 400-kV-1.4-GVA single-circuit three-phase line is examined. Results presented include a discussion on the effects of mitigation loops with or without capacitor compensation
1 April 1996 in IEEE Transactions on Power Delivery
Photovoltaic microgeneration (μG) located near the domestic consumers is expected to increase more in the future. Known issues regarding high μG penetration are voltage rise and reverse power flow. The concept of self‐consumption and storage is emerging as a way to improve network power supply quality and to facilitate the integration of small renewable energy sources in low voltage networks. This paper intends to give a further contribution by assessing the improvements provided by allowing domestic clients to consume and store the energy they produce. The tool at hand to study the situation is the unbalanced three‐phase load flow algorithm, based on the power summation technique, improved with the capability of explicitly compute the neutral voltages. The behaviour of a test radial distribution grid is assessed in different operating conditions, namely winter/summer, μG penetration level and μG operating mode. Voltage profile, active power flow in the service transformer and losses are monitored. The results suggest that self‐consumption with storage operating mode is a promising solution. Voltage excursions above normal grid voltage operating limits were not observed, the situation of reverse active power flow does not occur and the power losses are reduced.
15 February 2018 in IET Renewable Power Generation
Nowadays, a strong concern to decrease greenhouse gas emissions is encouraging the implementation of renewable energy sources closer to end‐users, in low‐voltage (LV) distribution networks. Due to the expected high microgeneration (µG) penetration level, several problems are likely to arise, such as overvoltages and reverse power flow. This study presents a review of the several techniques used to deal with these problems. These are compared in terms of their capacity to smooth the voltage profile and avoid reverse power flow. An unbalanced three‐phase power flow algorithm, based on current summation method for radial distribution networks, is proposed. A study based on a highly unbalanced test radial LV distribution network for a typical summer day, with a high µG penetration, is performed. The voltage profile, active power flow in the service transformer, and power losses on the network are the monitored electrical quantities. The obtained results indicate that self‐consumption with storage is the recommended solution to eliminate overvoltages, to avoid reverse power flow and allow for a decreasing in the power losses. Nevertheless, the economic viability of this solution must be carefully assessed, because the profitability of the project is not straightforward at the current time.
1 July 1996 in IEEE Transactions on Power Delivery