10 November 2023 in Diabetes Care
Verified
Journal Article
Closed access
PDF file
PBPilar Isabel Beato-Víbora
Pilar Isabel Beato-Víbora
ACAna Chico
Ana Chico
JMJesus Moreno-Fernandez
Jesus Moreno-Fernandez
VBVirginia Bellido
Virginia Bellido
LNLía Nattero-Chávez
Lía Nattero-Chávez
CARMEN QuirósCARMEN Quirós
CARMEN Quirós
OBJECTIVE: Advanced hybrid closed-loop systems (AHCL) have been shown to improve glycemic control and patient-reported outcomes in type 1 diabetes. The aim was to analyze the outcomes of two commercially available AHCL in real life. RESEARCH DESIGN AND METHODS: A prospective study was performed, including adolescents and adults with type 1 diabetes, AHCL naïve, from 14 centers, who initiated the use of MM780G with SmartGuard or Tandem t:slimX2 with Control-IQ. Baseline and 3-month evaluations were performed, assessing HbA1c, time in different glycemic ranges, and patient-reported outcomes. The primary outcome was the between-group time in range 70–180 mg/dL difference from beginning to end of follow-up. RESULTS: One hundred fifty participants were included, with 75 initiating each system (age: 39.9 ± 11.4 years [16–72]; 64% female; diabetes duration: 21.6 ± 11.9 years). Time in range increased from 61.53 ± 14.01% to 76.17 ± 9.48% (P < 0.001), with no between-group differences (P = 0.591). HbA1c decreased by 0.56% (95% CI 0.44%, 0.68%) (6 mmol/mol, 95% CI 5, 7) (P < 0.001), from 7.43 ± 1.07% to 6.88 ± 0.60% (58 ± 12 to 52 ± 7 mmol/mol) in the MM780G group, and from 7.14 ± 0.70% to 6.56 ± 0.53% (55 ± 8 to 48 ± 6 mmol/mol) in the Control-IQ group (both P < 0.001 to baseline, P = 0.819 between groups). No superiority of one AHCL over the other regarding fear of hypoglycemia or quality of life was found. Improvement in diabetes-related distress was higher in Control-IQ users (P = 0.012). Sleep quality was improved (PSQI: from 6.94 ± 4.06 to 6.06 ± 4.05, P = 0.004), without differences between systems. Experience with AHCL, evaluated by the INSPIRE measures, exceeded the expectations. CONCLUSIONS: The two AHCL provide significant improvement in glucose control and satisfaction, with no superiority of one AHCL over the other.

28 February 2024 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
CARMEN QuirósCARMEN Quirós
CARMEN Quirós
MHMaria Teresa Herrera
Maria Teresa Herrera
JAJudit Amigó
Judit Amigó
AWAna M Wägner
Ana M Wägner
PBPilar I Beato-Vibora
Pilar I Beato-Vibora
VPVerónica Perea
Verónica Perea
Aims: To compare glycemic control and maternal–fetal outcomes of women with type 1 diabetes (T1D) using hybrid closed loop (HCL) vs. multiple daily insulin injections (MDI) plus continuous glucose monitoring (CGM). Methods: Multicenter prospective cohort study of pregnant women with T1D in Spain. We evaluated HbA1c and time spent within (TIR), below (TBR) and above (TAR) the pregnancy-specific glucose range 3.5–7.8 mmol/L. Adjusted models were performed for adverse pregnancy outcomes including baseline maternal characteristics and center. Results: 112 women were included (HCL n=59). Women in the HCL group had a longer duration of diabetes and higher rates of prepregnancy care. There were no between-group differences in HbA1c in any trimester. However, in the second trimester, MDI users had a greater decrease in HbA1c (-6.12±9.06 vs. -2.16 ±7.42 mmol/mol, p=0.031). No differences in TIR (3.5-7.8 mmol/L) and TAR were observed between HCL and MDI users, but with a higher total insulin dose in the second trimester (+0.13 IU/Kg/d). HCL therapy was associated with increased maternal weight gain during pregnancy (βadjusted 3.20 kg, 95%CI 0.90-5.50). Regarding neonatal outcomes, newborns of HCL users were more likely to have higher birthweight (βadjusted 279.0 g, 95% CI 39.5-518.5) and macrosomia (ORadjusted 3.18, 95% CI 1.05-9.67) compared to MDI users. These associations disappeared when maternal weight gain or third trimester HbA1c were included in the models. Conclusions: In a real-world setting, HCL users gained more weight during pregnancy and had larger newborns than MDI users, while achieving similar glycemic control in terms of HbA1c and TIR.

14 May 2024 in Diabetes Therapy
Verified
Journal Article
Open access
PDF file
NANúria Alonso-Carril
Núria Alonso-Carril
SRSilvia Rodriguez-Rodríguez
Silvia Rodriguez-Rodríguez
CARMEN QuirósCARMEN Quirós
CARMEN Quirós
BBBelén Berrocal
Belén Berrocal
AAAntonio J. Amor
Antonio J. Amor
VPVerónica Perea
Verónica Perea
Objective Diabetes Self-Management Education and Support (DSMES) is a critical component of diabetes care. This study aims to examine the effect of online-based educational interventions on diabetes management compared to face-to-face interventions. Methods A systematic review was conducted by searching three databases for studies in English or Spanish between December 2023 and March 2024. The inclusion criteria were studies that compared face-to-face DSMES with online interventions. Results The follow-up duration of the trials ranged from 1 to 12 months. Multidisciplinary teams delivered online DSMES through various means, including Short Message Service (SMS), telephone calls, video calls, websites, and applications. Online DSMES was found to be comparable to face-to-face interventions in terms of glycated hemoglobin (HbA1c) levels in people with type 1 diabetes (T1D). In contrast, online interventions that focus on weight management in people with type 2 diabetes (T2D) have shown a significant reduction in HbA1c compared to face-to-face interventions. Online DSMES was found to be superior in terms of quality of life and cost-effectiveness in both T1D and T2D. None of the analyzed studies explored the differences between individual and group methodologies. Conclusions The current evidence indicates that online DSMES services provide at least comparable biomedical benefits to face-to-face interventions, suggesting that online interventions could be incorporated into clinical practice as a complement or reinforcement. However, further research is needed to explore the potential benefits and effectiveness of online group sessions in DSMES.

14 February 2025 in Cardiovascular Diabetology
Verified
Journal Article
Open access
PDF file
Carlos Puig-JovéCarlos Puig-Jové
Carlos Puig-Jové
CVClara Viñals
Clara Viñals
ICIgnacio Conget
Ignacio Conget
CARMEN QuirósCARMEN Quirós
CARMEN Quirós
IVIrene Vinagre
Irene Vinagre
AAAntonio J. Amor
Antonio J. Amor
Since the arrival of continuous glucose monitoring (CGM), the relationship between the glucose management indicator (GMI) and HbA1c has been a topic of considerable interest in diabetes research. This study aims to explore the association between the GMI/HbA1c ratio and the presence of preclinical carotid atherosclerosis in type 1 diabetes (T1D). Individuals with T1D and no prior history of cardiovascular disease were recruited from two centers. Carotid ultrasonography was performed using a standardized protocol and carotid plaques were defined as intima-media thickness ≥ 1.5 mm. CGM-derived data were collected from a 14-day report. A GMI/HbA1c ratio < 0.90 was selected to identify “fast-glycator” phenotype. A total of 584 participants were included (319 women, 54.6%), with a mean age of 48.8 ± 10.7 years and a mean diabetes duration of 27.5 ± 11.4 years. Carotid plaques were present in 231 subjects (39.6%). Approximately 43.7% and 13.4% of participants showed absolute differences of ≥ 0.5 and ≥ 1.0 between 14-day GMI and HbA1c, respectively. Among patients ≥ 48 years, the fast-glycator phenotype was independently associated with presence of plaques (OR 2.27, 95%CI: 1.06–4.87), even after adjusting for non-specific and T1D-specific risk factors and statin treatment. No significant association was observed in younger subjects (p for interaction < 0.05). Fast-glycator phenotype is independently associated with atherosclerosis in T1D individuals aged ≥ 48 years, suggesting an age-related increase in the glycation risk. These findings highlight the potential of the GMI/HbA1c ratio for cardiovascular risk stratification in this population.

Verified
Journal Article
Open access
PDF file
ASAndreu Simó
Andreu Simó
MIMontse Ibarra
Montse Ibarra
MLMIREIA LIBRAN
MIREIA LIBRAN
SRSilvia Rodríguez
Silvia Rodríguez
VPVerónica Perea
Verónica Perea
MBMaria-José Barahona
Maria-José Barahona
Background and objectives: Sarcopenic obesity (SO) is an emerging problem, especially in candidates for bariatric surgery (BS). We hypothesized that musculoskeletal ultrasound (MUS), a simple and accessible method, could be a reliable index of SO. Materials and Methods: A cross-sectional pilot study including 122 subjects (90 cases and 32 controls, 73% female, mean age: 51.2 years) who underwent BS was conducted at University Hospital Mútua Terrassa. The lean mass (LM) was calculated by bioelectrical impedance analysis (BIA) and the thigh muscle thickness (TMT) by MUS. To identify the subjects with SO by BIA, we used skeletal muscle index (SMI). The validity of MUS was determined using the ROC curve. Results: The mean BMI in the obesity group was 44.22 kg/m2. We observed a correlation between the LM and SMI assessed by BIA and the TMT assessed by MUS (R = 0.46, p < 0.001). This correlation was maintained at significant levels in the SO group (n = 40): R = 0.79; p = 0.003). The TMT assessed by MUS was able to predict SMI using BIA (AUC 0.77; 95% CI: 0.68242 to 0.84281). The optimal cut-off point for maximum efficiency was 1.57 cm in TMT (sensitivity = 75.6% and specificity = 71.1%). Conclusions: The TMT of the quadriceps assessed by US is a useful tool for identifying subjects with SO. Larger studies to validate this simple low-cost screening strategy are warranted.

9 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EGErnesto Guevara
Ernesto Guevara
ASAndreu Simó
Andreu Simó
VPVerónica Perea
Verónica Perea
CARMEN QuirósCARMEN Quirós
CARMEN Quirós
Carlos Puig-JovéCarlos Puig-Jové
Carlos Puig-Jové
MBMaria-José Barahona
Maria-José Barahona
Objectives: With the increasing prevalence of diabetes and frailty among older adults, there is an urgent need for precision medicine that incorporates comprehensive geriatric assessments, including frailty detection. This scoping review aims to map and synthesize the available evidence on validated tools for detecting pre-frailty and frailty in community-dwelling elderly individuals with diabetes and outpatient diabetes patients. Specifically, it addresses: (1) What validated tools are available for detecting pre-frailty and frailty in this population? (2) How are these tools associated with outcomes such as glycemic control, hypoglycemia, and metabolic phenotypes? (3) What gaps exist in the literature regarding these tools? Methods: The review followed PRISMA-ScR guidelines, conducting a systematic search across PubMed, Cochrane Library, and Web of Science. The inclusion criteria focused on studies involving individuals aged 70 years and older with diabetes, emphasizing tools with predictive capacity for disability and mortality. Results: Eight instruments met the inclusion criteria, including the Frailty Index, Physical Frailty Phenotype, and Clinical Frailty Scale. These tools varied in domains such as physical, psychological, and social aspects of frailty and their association with glycemic control, hypoglycemia, and metabolic phenotypes. The review identified significant gaps in predicting diabetes-related complications and their clinical application. Conclusions: Routine management of older adults with diabetes should incorporate frailty detection, as it is crucial for their overall health. Although widely used, the reviewed tools require refinement to address the unique characteristics of this population. Developing tailored instruments will enhance precision medicine, leading to more effective, individualized interventions for elderly individuals with diabetes.